In-situ sensitivity of a totally-implantable microphone

被引:2
|
作者
D'hondt, Christiane [1 ,2 ]
Wouters, Jan [1 ]
Verhaert, Nicolas [1 ,3 ]
机构
[1] Univ Leuven, Dept Neurosci, Res Grp ExpORL, KU Leuven, Onderwijs Navorsing 2,Herestr 49,Bus 721, B-3000 Leuven, Belgium
[2] Cochlear Technol Ctr Belgium, Mechelen, Belgium
[3] Univ Hosp Leuven, Dept Otolaryngol Head & Neck Surg, Leuven, Belgium
关键词
middle ear implant; fully-implantable middle ear implant; subcutaneous microphone; microphone sensitivity; HEARING-AIDS; THICKNESS; SYSTEM;
D O I
10.1016/j.heares.2020.108018
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
One of the key components of fully-implantable hearing devices is the implantable microphone. A crucial parameter when characterizing implantable microphones is the acoustic sensitivity, as it is one of the input parameters for the fitting algorithm and influences the achievable gain. The aim of our study was to investigate the sensitivity of an implanted subcutaneous microphone over time to answer two research questions: (1) How does the sensitivity change once the microphone is implanted under the skin (pre-op versus in-situ)? and (2) How does the sensitivity change from short-term to mid-term? We have measured the in-situ microphone sensitivity in three subjects implanted with a fully-implantable active middle ear implant from 2 weeks up to 20 weeks after implantation with a research software. The microphone sensitivity changed after implantation with clinically relevant changes around the resonance frequency of the microphone. Based on our results, it is essential to measure the in-situ microphone sensitivity at the time of initial fitting of the implant. Once implanted no clinically relevant changes in the microphone sensitivity were observed over time, with a clear decrease in variability over time. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Final stretch for the totally implantable TAH
    Nose, Y
    ARTIFICIAL ORGANS, 1997, 21 (02) : 89 - 90
  • [32] A new floating piezoelectric microphone for the implantable middle ear microphone in experimental studies
    Jia, Xian-Hao
    Gao, Na
    Xu, Xin-da
    Wu, Yong-Zhen
    Kang, Hou-Yong
    Chi, Fang-Lu
    ACTA OTO-LARYNGOLOGICA, 2016, 136 (12) : 1248 - 1254
  • [33] EXPERIENCES WITH TOTALLY IMPLANTABLE CARDIAC PACEMAKERS
    KING, RL
    LAWRENCE, GH
    PAINE, RM
    HUGHES, ML
    JOURNAL OF CARDIOVASCULAR SURGERY, 1966, : 210 - &
  • [34] Development of a totally implantable artificial larynx
    Verkerke, GJ
    Veenstra, A
    de Vries, MP
    Schutte, HK
    Busscher, HJ
    Herrmann, IF
    Van der Mei, HC
    Rakhorst, G
    VOICE UPDATE, 1996, 97 : 311 - 317
  • [35] Is a totally implantable hearing aid realistic?
    Suzuki, J
    Kodera, K
    TRANSPLANTS AND IMPLANTS IN OTOLOGY - III, PROCEEDINGS, 1996, : 315 - 322
  • [36] A TOTALLY IMPLANTABLE SYSTEM FOR INTRAVENOUS CHEMOTHERAPY
    HANNA, SS
    GORMAN, PR
    KERR, I
    SONE, M
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1986, 9 (03): : A69 - A69
  • [37] A TOTALLY IMPLANTABLE CATHETER SYSTEM - COMMENT
    STRAIF, K
    KLEINSCHMIDT, R
    LEISS, O
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1986, 111 (11) : 438 - 438
  • [38] EXPERIENCES WITH TOTALLY IMPLANTABLE CARDIAC PACEMAKERS
    KING, RL
    LAWRENCE, GH
    PAINE, RM
    HUGHES, ML
    JOURNAL OF CARDIOVASCULAR SURGERY, 1966, 7 (04): : 251 - &
  • [39] TOTALLY IMPLANTABLE SYSTEM FOR PERITONEAL ACCESS
    PFEIFLE, CE
    HOWELL, SB
    MARKMAN, M
    LUCAS, WE
    JOURNAL OF CLINICAL ONCOLOGY, 1984, 2 (11) : 1277 - 1280
  • [40] TOTALLY IMPLANTABLE DIRECTIONAL DOPPLER FLOWMETERS
    ALLEN, HV
    KNUTTI, JW
    MEINDL, JD
    BIOTELEMETRY AND PATIENT MONITORING, 1979, 6 (03) : 118 - 132