LCFI charge transfer inefficiency studies for CCD vertex detectors

被引:0
|
作者
Sopczak, Andre [1 ]
机构
[1] Univ Lancaster, Lancaster LA1 4YW, England
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Linear Collider Flavour Identification (LCFI) collaboration studies CCD detectors for quark Havour identification in the framework of a future linear e(+)e(-) collider. The flavour identification is based on precision reconstruction of charged tracks very close to the interaction point. Therefore, this detector will be exposed to a high level of radiation and thus an important aspect of the vertex detector development are radiation hardness studies. Results of detailed simulations of the charged transport properties of a CCD prototype chip are reported and compared with initial measurements. The simulation program allows to study the effect of radiation damage after the exposure of the detector to a realistic radiation dose, which is expected in the environment of detector operation at a future LC.
引用
收藏
页码:1494 / 1498
页数:5
相关论文
共 50 条
  • [31] NATIVE AND IRRADIATED CHARGE TRANSFER INEFFICIENCY CHARACTERIZATION
    Pasquier, J. -F.
    GAIA: AT THE FRONTIERS OF ASTROMETRY, 2011, 45 : 61 - 66
  • [32] CHARACTERIZATION OF CHARGE-TRANSFER DEVICES WITH VARIABLE TRANSFER INEFFICIENCY
    BARSAN, RM
    REVUE ROUMAINE DE PHYSIQUE, 1979, 24 (05): : 471 - 485
  • [33] Assessment of space proton radiation-induced charge transfer inefficiency in the CCD204 for the Euclid space observatory
    Gow, J. P. D.
    Murray, N. J.
    Holland, A. D.
    Hall, D. J.
    Cropper, M.
    Burt, D.
    Hopkinson, G.
    Duvet, L.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [34] THE CAPABILITIES OF CHARGE-COUPLED DEVICE (CCD) DETECTORS
    PURLL, DJ
    OBSERVATORY, 1981, 101 (1044): : 138 - 138
  • [35] Charge diffusion in CCD X-ray detectors
    Pavlov, GG
    Nousek, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (2-3): : 348 - 366
  • [36] Charge collection inefficiency of p-in-n silicon microstrip detectors
    Casse, G
    Allport, PP
    Biagi, SF
    Booth, PSL
    Bowcock, TJV
    Jackson, JN
    Garcia, SMI
    MECHANICS AND MATERIAL ENGINEERING FOR SCIENCE AND EXPERIMENTS, 2001, : 188 - 192
  • [37] CORRELATION BETWEEN MOST 1/F NOISE AND CCD TRANSFER INEFFICIENCY
    VANDAMME, LKJ
    DEVRIES, RGMP
    SOLID-STATE ELECTRONICS, 1985, 28 (10) : 1049 - 1056
  • [38] Simulation of the charge transfer inefficiency of column parallel CCDs
    Maneuski, Dzmitry
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01): : 252 - 254
  • [39] Radiation-induced charge transfer inefficiency in Charge-Coupled Devices: Sentinel-4 CCD pre-development as a case study
    Prod'homme, T.
    Belloir, J. -M.
    Weber, H.
    Courreges-Lacoste, G. Bazalgette
    Meynart, R.
    Nowicki-Bringuier, Y. -R.
    Caron, J.
    Levillain, Y.
    Woffinden, C.
    Lord, B.
    Mackie, R.
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XVIII, 2014, 9241
  • [40] Assessment of proton radiation-induced charge transfer inefficiency in the CCD273 detector for the Euclid Dark Energy Mission
    Gow, J. P. D.
    Murray, N. J.
    Hall, D. J.
    Clarke, A. S.
    Burt, D.
    Endicott, J.
    Holland, A. D.
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY V, 2012, 8453