Prosthesis-patient mismatch after transcatheter aortic valve implantation

被引:4
|
作者
Leone, Pier Pasquale [1 ]
Pagnesi, Matteo [2 ]
Regazzoli, Damiano [1 ]
Latib, Azeem [3 ]
机构
[1] Humanitas Clin & Res Ctr IRCCS, Cardio Ctr, UO Cardiol, Rozzano, MI, Italy
[2] IRCCS Osped San Raffaele, UO Cardiol Interventist, Milan, Italy
[3] Montefiore Med Ctr, Cardiol Dept, New York, NY USA
关键词
Aortic stenosis; Prosthesis-patient mismatch; Small annuli; Transcatheter aortic valve implantation; Valve-in-valve; LONG-TERM SURVIVAL; HIGH-RISK PATIENTS; CLINICAL IMPACT; BIOPROSTHETIC VALVE; EVOLUT PRO; REPLACEMENT; OUTCOMES; MORTALITY; STENOSIS; PREDICTORS;
D O I
10.1714/3487.34670
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prosthesis-patient mismatch (PPM) is present when the actual area of an implanted prosthetic valve is too small compared to the size of the patient's body. Its main hemodynamic consequence is that of generating higher than expected gradients through prosthetic valves which are normally functioning. This review aims to update on the incidence of PPM after transcatheter aortic valve implantation (TAVI) and its long-term clinical impact through a review of the clinical studies available to date. Furthermore, this review will focus on some particular settings, such as TAVI procedures in small annuli or valve-in-valve, which have a higher risk of encountering this complication. Finally, we will focus on the strategies available to reduce the risk of PPM when planning a TAVI procedure.
引用
收藏
页码:26S / 34S
页数:9
相关论文
共 50 条
  • [31] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement It Is Neither Rare Nor Benign
    Pibarot, Philippe
    Clavel, Marie-Annick
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (22) : 2712 - 2716
  • [32] Long-term outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement
    Compagnone, Miriam
    Marchetti, Giulia
    Taglieri, Nevio
    Ghetti, Gabriele
    Bruno, Antonio Giulio
    Orzalkiewicz, Mateusz
    Marrozzini, Cinzia
    Reggiani, Maria-Letizia Bacchi
    Palmerini, Tullio
    Galie, Nazzareno
    Saia, Francesco
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 318 : 27 - 31
  • [33] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement Of Asians and Non-Asians
    Wang, Jian'an
    He, Yuxin
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (24) : 2682 - 2684
  • [34] Racial Differences in the Incidence and Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Park, Hanbit
    Ahn, Jung-Min
    Kang, Do-Yoon
    Kim, Juyong Brian
    Yeung, Alan C.
    Nishi, Takeshi
    Fearon, William F.
    Cantey, Eric Page
    Flaherty, James D.
    Davidson, Charles J.
    Malaisrie, S. Christopher
    Kim, Sehee
    Yun, Sung-Cheol
    Ko, Euihong
    Lee, Seung-Ah
    Kim, Dae-Hee
    Kim, Ho Jin
    Kim, Joon Bum
    Choo, Suk Jung
    Park, Duk-Woo
    Park, Seung-Jung
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (24) : 2670 - 2681
  • [35] Impact of Valve Size on Prosthesis-Patient Mismatch and Aortic Valve Gradient After Transcatheter versus Surgical Aortic Valve Replacement
    Aalaei-Andabili, Seyed Hossein
    Lee, Teng C.
    Waheed, Nida
    Bavry, Anthony A.
    Petersen, John W.
    Wayangankar, Siddharth
    Arnaoutakis, George J.
    Anderson, R. David
    Beaver, Thomas M.
    [J]. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2019, 14 (03) : 243 - 250
  • [36] Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement
    Freeman, Melanie
    Webb, John G.
    Willson, Alexander B.
    Wheeler, Miriam
    Blanke, Philipp
    Moss, Robert R.
    Thompson, Christopher R.
    Munt, Brad
    Norgaard, Bjarne L.
    Yang, Tae-Hyun
    Min, James K.
    Poulsen, Steen
    Hansson, Nicolaj C.
    Binder, Ronald K.
    Toggweiler, Stefan
    Hague, Cameron
    Wood, David A.
    Pibarot, Philippe
    Leipsic, Jonathon
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (04) : 248 - 255
  • [37] Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve
    Kameshima, Haruka
    Izumo, Masaki
    Suzuki, Tomomi
    Ohara, Hiroshi
    Sato, Yukio
    Watanabe, Mika
    Kuwata, Shingo
    Okuyama, Kazuaki
    Kamijima, Ryo
    Takai, Manabu
    Kou, Seisyou
    Tanabe, Yasuhiro
    Harada, Tomoo
    Akashi, Yoshihiro J.
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 8
  • [38] Impact of Prosthesis-patient mismatch on clinical outcome among patients with aortic stenosis undergoing Transcatheter aortic valve implantation with the CoreValve prosthesis
    Munoz-Garcia, E.
    Munoz-Garcia, M.
    Munoz Garcia, AJAntonio Jesus
    Carrasco Chinchilla, F.
    Rodriguez-Bailon, I.
    Dominguez-Franco, A. J.
    Alonso-Briales, J. H.
    Hernandez-Garcia, J. M.
    Jimenez-Navarro, M. F.
    De Teresa-Galvan, E.
    [J]. EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 : 193 - 193
  • [39] Impact of prosthesis-patient mismatch on hemodynamic and clinical outcomes after transcatheter aortic valve implantation with balloon-expandable valves
    Ewe, S. H.
    Delgado, V.
    Tamborini, G.
    Muratori, M.
    Pepi, M.
    Van der Kley, F.
    Fusari, M.
    Biglioli, P.
    Bax, J. J.
    Marsan, N. A.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 904 - 904
  • [40] Prosthesis-patient mismatch after transcatheter aortic valve implantation: prevalence and prognostic impact with respect to baseline left ventricular function
    Schofer, Niklas
    Deuschl, Florian
    Ruebsamen, Nicole
    Skibowski, Johanna
    Seiffert, Moritz
    Voigtlaender, Lisa
    Schaefer, Andreas
    Schneeberger, Yvonne
    Schirmer, Johannes
    Reichenspurner, Hermann
    Blankenberg, Stefan
    Conradi, Lenard
    Schafer, Ulrich
    [J]. EUROINTERVENTION, 2019, 14 (16) : 1648 - 1655