Prosthesis-patient mismatch after transcatheter aortic valve implantation

被引:4
|
作者
Leone, Pier Pasquale [1 ]
Pagnesi, Matteo [2 ]
Regazzoli, Damiano [1 ]
Latib, Azeem [3 ]
机构
[1] Humanitas Clin & Res Ctr IRCCS, Cardio Ctr, UO Cardiol, Rozzano, MI, Italy
[2] IRCCS Osped San Raffaele, UO Cardiol Interventist, Milan, Italy
[3] Montefiore Med Ctr, Cardiol Dept, New York, NY USA
关键词
Aortic stenosis; Prosthesis-patient mismatch; Small annuli; Transcatheter aortic valve implantation; Valve-in-valve; LONG-TERM SURVIVAL; HIGH-RISK PATIENTS; CLINICAL IMPACT; BIOPROSTHETIC VALVE; EVOLUT PRO; REPLACEMENT; OUTCOMES; MORTALITY; STENOSIS; PREDICTORS;
D O I
10.1714/3487.34670
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prosthesis-patient mismatch (PPM) is present when the actual area of an implanted prosthetic valve is too small compared to the size of the patient's body. Its main hemodynamic consequence is that of generating higher than expected gradients through prosthetic valves which are normally functioning. This review aims to update on the incidence of PPM after transcatheter aortic valve implantation (TAVI) and its long-term clinical impact through a review of the clinical studies available to date. Furthermore, this review will focus on some particular settings, such as TAVI procedures in small annuli or valve-in-valve, which have a higher risk of encountering this complication. Finally, we will focus on the strategies available to reduce the risk of PPM when planning a TAVI procedure.
引用
收藏
页码:26S / 34S
页数:9
相关论文
共 50 条
  • [21] Prosthesis-patient mismatch after aortic valve replacement
    Dahou A.
    Mahjoub H.
    Pibarot P.
    [J]. Current Treatment Options in Cardiovascular Medicine, 2016, 18 (11)
  • [22] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement Has It Become Obsolete?
    Ternacle, Julien
    Abbas, Amr E.
    Pibarot, Philippe
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (09) : 977 - 980
  • [23] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement in Asian Patients
    Chen, Ying-Hwa
    Chang, Hsiao-Huang
    Kuo, Chia-Cheng
    Leu, Hsin-Bang
    Lin, Su-Man
    [J]. ANNALS OF THORACIC SURGERY, 2022, 114 (05): : 1612 - 1619
  • [24] REPLY: Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement
    Okuno, Taishi
    Lanz, Jonas
    Heg, Dik
    Pilgrim, Thomas
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (01) : 139 - 139
  • [25] PROSTHESIS-PATIENT MISMATCH BETWEEN TRANSCATHETER HEART VALVES IN TRANSCATHETER AORTIC VALVE REPLACEMENT
    Sengupta, Aditya
    Zaid, Syed
    Storch, Jason
    Gupta, Eisha
    Hirji, Sameer
    Ahmad, Hasan
    Khan, Asaad
    Undemir, Cenap
    Ali, Omar
    Skiles, Jeffrey
    Goldberg, Joshua
    Lansman, Steven
    Kovacic, Jason
    Dangas, George D.
    Sharma, Samin K.
    Kini, Annapoorna Subhash
    Ramlawi, Basel
    Shah, Pinak
    Kaneko, Tsuyoshi
    Tang, Gilbert
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (11) : 1421 - 1421
  • [26] Prosthesis-patient mismatch in aortic valve disease: surgical versus transcatheter valve replacement
    Pibarot, Philippe
    [J]. EUROINTERVENTION, 2011, 7 (06) : 660 - 661
  • [27] The relevance of prosthesis-patient mismatch after aortic valve replacement
    Pibarot, Philippe
    Dumesnil, Jean G.
    [J]. NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (12): : 764 - 765
  • [28] Prosthesis-Patient Mismatch Based on Energy Loss Index After Transcatheter Aortic Valve Replacement
    Okuno, Taishi
    Pilgrim, Thomas
    Heg, Dik
    Stortecky, Stefan
    Praz, Fabien
    Windecker, Stephan
    Lanz, Jonas
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (21) : 2584 - 2586
  • [29] Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: A New Technology With an Old Problem
    Ortoleva, Jamel P.
    Gonzalez-Ciccarelli, Luis F.
    Kawabori, Masashi
    Cobey, Frederick C.
    Resor, Charles D.
    Shapeton, Alexander D.
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (08) : 2253 - 2255
  • [30] Relative prosthesis-patient mismatch after transcatheter aortic valve replacement: The impact of morbid obesity
    Airhart, Sophia
    Medvedev, Ivan
    Dean, Larry S.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (02) : 341 - 345