Integrated of PDMS Microfluidic Channel with cantilever based bio-sensor

被引:0
|
作者
Wang, Shuaipeng [1 ,2 ]
Chen, Yanning [1 ,2 ]
Zhang, Haifeng [1 ,2 ]
Zhao, Dongyan [1 ,2 ]
机构
[1] Beijing Smart Chip Microelect Technol Co Ltd, State Grid Key Lab Power Ind Chip Design & Anal T, 15 Xiaoying Rd E, Beijing, Peoples R China
[2] Beijing Smart Chip Microelect Technol Co Ltd, Beijing Engn Res Ctr High Reliabil IC Power Ind G, 15 Xiaoying Rd E, Beijing, Peoples R China
关键词
MEMS; cantilever; PDMS; bio-sensor;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel cantilever array sensor was microfabricated for precise bio-marker detection. The device was fabricated on a SOl wafer with CMOS compatible processes. In order to reducing the effect of k variation due to adsorption, a local biochemical reaction cavity was designed in the free end of the cantilever, the antibody-immobilization was performed in this local area by micro printing technology. This approach can be applied to enhance the performance of all the cantilever-based sensors. The PDMS package is designed to be used for the cantilever sensor which is greatly promoting the practicality of the sensor.
引用
收藏
页码:1189 / 1191
页数:3
相关论文
共 50 条
  • [31] Range Enhanced IR-UWB Remote Bio-sensor System with Integrated Communication
    Dhar, Sagar K.
    Das, Stabak
    Baidya, Noel
    2013 INTERNATIONAL CONFERENCE ON INFORMATICS, ELECTRONICS & VISION (ICIEV), 2013,
  • [32] Designing Four Channel Nano cavities coupled Photonic Crystal Based Bio-Sensor for Detection in Water Bactria
    Sharma, Varsha
    Kalyani, Vijay Laxmi
    2017 INTERNATIONAL CONFERENCE ON COMPUTING AND COMMUNICATION TECHNOLOGIES FOR SMART NATION (IC3TSN), 2017, : 85 - 89
  • [33] Gold Coated Microstructure Optical Fiber Based Plasmonic Bio-sensor
    Marma, R.
    Mollah, M. A.
    2019 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL INFORMATION AND COMMUNICATION TECHNOLOGY (EICT), 2019,
  • [34] Bio-Sensor based on Multiclass Support Vector Machine with a Reject Option
    Buchsbaum, Stav
    Keshet, Yossi
    Ozana, Nisan
    Zalevsky, Zeev
    MULTIMODAL BIOMEDICAL IMAGING XIV, 2019, 10871
  • [35] Development of a reactor type bio-sensor for trichloroethylene
    Han, TS
    Sasaki, S
    Yano, K
    Ikebukuro, K
    Atsushi, K
    Nagamune, T
    Karube, I
    ANALYTICAL LETTERS, 2003, 36 (03) : 539 - 547
  • [36] A mobile ad hoc bio-sensor network
    Li, YH
    Panwar, SS
    Mao, SW
    Burugupalli, S
    Lee, JH
    ICC 2005: IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS, VOLS 1-5, 2005, : 1241 - 1245
  • [37] The pacemaker electrode as bio-sensor for rate adaptation
    Strobel, JP
    Res, JCJ
    Malinowski, K
    Witte, J
    Ebner, E
    Rodiger, W
    Greco, OT
    Ardito, RV
    Andrade, JCS
    Schaldach, M
    PACEMAKER LEADS 1997, 1997, : 53 - 58
  • [38] An in-line osmometer for application in tissue based bio-sensor systems
    Mourlas, NJ
    Maluf, NI
    Kovacs, GTA
    TRANSDUCERS '01: EUROSENSORS XV, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2001, : 370 - 373
  • [39] Assertion-Based Verification Technique for ECG Bio-Sensor Algorithms
    Al-Hamadi, Hussam
    Gawanmeh, Amjad
    Al-Qutayri, Mahmoud
    2016 IEEE 59TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2016, : 549 - 552
  • [40] Nanophotonics bio-sensor using gold nanostructure
    Naya, Masayuki
    Tani, Takeharu
    Tomaru, Yuichi
    Li, Jingbo
    Murakami, Naoki
    PLASMONICS: METALLIC NANOSTRUCTURES AND THEIR OPTICAL PROPERTIES VI, 2008, 7032