Ray tracing for intraocular lens calculation

被引:107
|
作者
Preussner, PR
Wahl, J
Lahdo, H
Dick, B
Findl, O
机构
[1] Univ Mainz, Augenklin, D-6500 Mainz, Germany
[2] Univ Vienna, Augenklin, Vienna, Austria
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2002年 / 28卷 / 08期
关键词
D O I
10.1016/S0886-3350(01)01346-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To improve accuracy in intraocular lens (IOL) calculations and clarify the effect of various errors. Setting: University eye hospitals, Mainz, Germany, and Vienna, Austria. Methods: A numerical ray-tracing calculation has been developed for the pseudophakic eye. Individual rays are calculated and then undergo refractions on all surfaces of the IOL and cornea. The calculations do not use approximations; ie, the refractions are calculated exactly using Snell's law. Rays can be calculated for any distance from the optical axis and for other parameter variations. The effects of aspheric surfaces can also be investigated. Instead of IOL powers, manufacturers' IOL data (radii, refractive index, thickness) are used in the calculations for different IOL types. The resulting optical quality is visualized by using Landolt rings superimposed on the grid of retinal receptors. Results: Intraocular lens design, corneal asphericity, and specific spherical aberration influence the visual quality of the pseudophakic eye significantly. The IOL refractive power is an ambiguous parameter that cannot characterize the visual outcome sufficiently accurately for an IOL implanted at a given position. The effects can be calculated only in numerical ray tracing, not in Gaussian optics. The accuracy of numerical ray tracing is independent of axial length. Therefore, very long or very short eyes gain the most from the higher accuracy of this approach. For average-size eyes, however, the results are the same as with SRK calculations. Conclusion: Calculations in Gaussian optics should be replaced by state-of-the-art numerical methods, which can be run on any standard personal computer. (C) 2002 ASCRS and ESCRS.
引用
收藏
页码:1412 / 1419
页数:8
相关论文
共 50 条
  • [41] Comment on: Intraocular lens power calculation with ray tracing based on AS-OCT and adjusted axial length after myopic excimer laser surgery
    Cione, Ferdinando
    De Bernardo, Maddalena
    Rosa, Nicola
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (11): : 1349 - 1349
  • [42] Intraocular lens calculation in extreme myopia
    Preussner, Paul-Rolf
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (03): : 531 - 532
  • [43] INTRAOCULAR-LENS POWER CALCULATION
    HOPEROSS, M
    MOONEY, D
    EYE, 1988, 2 : 367 - 369
  • [44] Intraocular lens calculation in extreme myopia
    Haigis, Wolfgang
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05): : 906 - 911
  • [45] Intraocular lens power calculation software
    Kuchenbecker, J
    Behrens-Baumann, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 735 - 736
  • [46] Update on Intraocular Lens Calculation Formulas
    Melles, Ronald B.
    Kane, Jack X.
    Olsen, Thomas
    Chang, William J.
    OPHTHALMOLOGY, 2019, 126 (09) : 1334 - 1335
  • [47] Intraocular lens power calculation in children
    Eibschitz-Tsimhoni, Maya
    Archer, Steven M.
    Del Monte, Monte A.
    SURVEY OF OPHTHALMOLOGY, 2007, 52 (05) : 474 - 482
  • [48] CALCULATION OF THE THICKNESS OF AN INTRAOCULAR-LENS
    NAESER, K
    NAESER, EV
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (01): : 40 - 42
  • [49] CALCULATION OF INTRAOCULAR-LENS POWER
    SUNDERRAJ, P
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03): : 387 - 388
  • [50] Intraocular lens power calculation REPLY
    Jin, Haiying
    Rabsilber, Tanja T.
    Ehmer, Angela
    Borkenstein, Andreas F.
    Limberger, Il-Joo
    Guo, Haike
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2177 - 2178