Ray tracing for intraocular lens calculation

被引:107
|
作者
Preussner, PR
Wahl, J
Lahdo, H
Dick, B
Findl, O
机构
[1] Univ Mainz, Augenklin, D-6500 Mainz, Germany
[2] Univ Vienna, Augenklin, Vienna, Austria
来源
关键词
D O I
10.1016/S0886-3350(01)01346-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To improve accuracy in intraocular lens (IOL) calculations and clarify the effect of various errors. Setting: University eye hospitals, Mainz, Germany, and Vienna, Austria. Methods: A numerical ray-tracing calculation has been developed for the pseudophakic eye. Individual rays are calculated and then undergo refractions on all surfaces of the IOL and cornea. The calculations do not use approximations; ie, the refractions are calculated exactly using Snell's law. Rays can be calculated for any distance from the optical axis and for other parameter variations. The effects of aspheric surfaces can also be investigated. Instead of IOL powers, manufacturers' IOL data (radii, refractive index, thickness) are used in the calculations for different IOL types. The resulting optical quality is visualized by using Landolt rings superimposed on the grid of retinal receptors. Results: Intraocular lens design, corneal asphericity, and specific spherical aberration influence the visual quality of the pseudophakic eye significantly. The IOL refractive power is an ambiguous parameter that cannot characterize the visual outcome sufficiently accurately for an IOL implanted at a given position. The effects can be calculated only in numerical ray tracing, not in Gaussian optics. The accuracy of numerical ray tracing is independent of axial length. Therefore, very long or very short eyes gain the most from the higher accuracy of this approach. For average-size eyes, however, the results are the same as with SRK calculations. Conclusion: Calculations in Gaussian optics should be replaced by state-of-the-art numerical methods, which can be run on any standard personal computer. (C) 2002 ASCRS and ESCRS.
引用
收藏
页码:1412 / 1419
页数:8
相关论文
共 50 条
  • [31] Intraocular lens calculation for aspheric intraocular lenses
    Hoffmann, Peter C.
    Lindemann, Christoph R.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06): : 867 - 872
  • [32] Online intraocular lens calculation
    Buonsanti, Dante
    Raimundo, Miguel
    Findl, Oliver
    CURRENT OPINION IN OPHTHALMOLOGY, 2024, 35 (01) : 11 - 16
  • [33] Intraocular lens power calculation
    Olsen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2176 - 2177
  • [34] Intraocular lens power calculation for lens exchange
    Kora, Y
    Shimizu, K
    Yoshida, M
    Inatomi, M
    Ozawa, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (04): : 543 - 548
  • [35] Intraocular lens power calculation with ray tracing based on AS-OCT and adjusted axial length after myopic excimer laser surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    Ribeiro, Filomena J.
    Dias, Joao Mendanha
    Coutinho, Catarina P.
    Barboni, Piero
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (08): : 947 - 953
  • [36] Intraocular lens calculation in post-LASIK eyes using ray tracing with the data from a Placido disk-Scheimpflug tomographer
    Preussner, Paul-Rolf
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (01): : 116 - 116
  • [37] Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation
    Ghoreyshi, Mohammad
    Khalilian, Ahmadreza
    Peyman, Mohammadreza
    Mohammadinia, Mohaddeseh
    Peyman, Alireza
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2018, 30 (01): : 63 - 67
  • [38] Generalized ray tracing method for the calculation of the peripheral refraction induced by an ophthalmic lens
    Rojo, Pilar
    Royo, Santiago
    Caum, Jesus
    Ramirez, Jorge
    Madariaga, Ines
    OPTICAL ENGINEERING, 2015, 54 (02)
  • [39] Thin lens ray tracing
    Gatland, IR
    AMERICAN JOURNAL OF PHYSICS, 2002, 70 (12) : 1184 - 1186
  • [40] INTRAOCULAR-LENS CALCULATION FORMULAS FOR NEW INTRAOCULAR-LENS IMPLANTS
    BARRETT, GD