Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study

被引:8
|
作者
Moorthy, Vikaesh [1 ]
Chen, Jerry Yongqiang [2 ]
Liow, Ming Han Lincoln [2 ]
Chin, Pak Lin [2 ]
Chia, Shi-Lu [2 ]
Lo, Ngai Nung [2 ]
Yeo, Seng Jin [2 ]
机构
[1] Natl Univ Singapore, Yong Loo Lin Sch Med, 1E Kent Ridge Rd,NUHS Tower Block,Level 11, Singapore 119228, Singapore
[2] Singapore Gen Hosp, Dept Orthpaed Surg, Block 6 Level 7,Outram Rd, Singapore 169608, Singapore
关键词
Patient-specific instrumentation; Total knee arthroplasty; Lower limb alignment; Functional outcomes; Patient-reported outcome measures; POSITIONING GUIDES; ALIGNMENT OUTCOMES; IMPROVED ACCURACY; BLOOD-LOSS; CT; REPLACEMENT; MULTICENTER; BENEFIT; SF-36;
D O I
10.1007/s00402-020-03729-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Patient-specific instrumentation (PSI) utilizes three-dimensional imaging to produce total knee arthroplasty cutting jigs which matches patient's native anatomy. However, there are limited mid- to long-term studies examining its clinical efficacy. The aim of this study was to compare functional outcomes of PSI surgery versus conventional TKA surgery at 5-year follow-up. Materials and methods Sixty patients were prospectively recruited into either the MRI-based PSI or conventional TKA group. Functional outcomes were assessed using the Knee Society Function Score (KSFS), Knee Society Knee Score (KSKS) and Oxford Knee Score (OKS), while quality of life was evaluated with the Physical Component Score (PCS) and Mental Component Score (MCS) of Short-Form 36 and compared between the two groups at 5-year follow-up. Results Although the PCS was 7 +/- 3 points better in the PSI group preoperatively (p = 0.017), it became 5 +/- 2 points worse than the conventional group at 5-year follow-up (p = 0.025). As compared to the PSI group, the conventional group showed a significantly greater improvement in PCS at 5 years as compared to before surgery (p = 0.003). There were no significant differences in KSFS, KSKS, OKS or MCS between the two groups. Conclusions PSI TKA did not result in improved functional outcomes or better quality of life when compared to conventional TKA. The additional costs and waiting time associated with PSI are not justifiable and therefore not recommended as an alternative to conventional TKA.
引用
收藏
页码:669 / 674
页数:6
相关论文
共 50 条
  • [31] Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study
    Andrzej Kotela
    Ireneusz Kotela
    International Orthopaedics, 2014, 38 : 2099 - 2107
  • [32] Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation
    Meng Zhu
    Jerry Yongqiang Chen
    Hwei Chi Chong
    Andy Khye Soon Yew
    Leon Siang Shen Foo
    Shi-Lu Chia
    Ngai Nung Lo
    Seng Jin Yeo
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2567 - 2572
  • [33] Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation
    Zhu, Meng
    Chen, Jerry Yongqiang
    Chong, Hwei Chi
    Yew, Andy Khye Soon
    Foo, Leon Siang Shen
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (08) : 2567 - 2572
  • [34] Functional Outcome and Quality of Life After Patient-Specific Instrumentation in Total Knee Arthroplasty
    Prakash, Jatin
    JOURNAL OF ARTHROPLASTY, 2016, 31 (04): : 923 - 924
  • [35] Functional Outcome and Quality of Life after Patient-Specific Instrumentation in Total Knee Arthroplasty
    Chen, Jerry Yonggiang
    Chin, Pak Lin
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    JOURNAL OF ARTHROPLASTY, 2015, 30 (10): : 1724 - 1728
  • [36] Correction to: No difference in mid-term survival and clinical outcome between patient-specific and conventional instrumented total knee arthroplasty: a randomized controlled trial
    M. G. M. Schotanus
    B. Boonen
    W. van der Weegen
    H. Hoekstra
    R. van Drumpt
    R. Borghans
    R. Vos
    L. van Rhijn
    N. P. Kort
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1469 - 1469
  • [37] A comparison of patient-specific and conventional instrumentation for total knee arthroplasty A MULTICENTRE RANDOMISED CONTROLLED TRIAL
    Abane, L.
    Anract, P.
    Boisgard, S.
    Descamps, S.
    Courpied, J. P.
    Hamadouche, M.
    BONE & JOINT JOURNAL, 2015, 97B (01): : 56 - 63
  • [38] Functional outcomes in patient specific instrumentation vs. conventional instrumentation for total knee arthroplasty; a systematic review and meta-analysis of prospective studies
    Branavan Rudran
    Henry Magill
    Nikhil Ponugoti
    Andy Williams
    Simon Ball
    BMC Musculoskeletal Disorders, 23
  • [39] Patient-Specific CT-Based Instrumentation versus Conventional Instrumentation in Total Knee Arthroplasty: A Prospective Randomized Controlled Study on Clinical Outcomes and In-Hospital Data (vol 2015, 165908, 2015)
    Kotela, Andrzej
    Lorkowski, Jacek
    Kucharzewski, Marek
    Wilk-Franczuk, Magdalena
    Sliwinski, Zbigniew
    Franczuk, Boguslaw
    Legosz, Pawel
    Kotela, Ireneusz
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [40] Patient-Specific Cutting Guides Were Not Better Than Conventional Instrumentation for Total Knee Arthroplasty
    Mihalko, William M.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (22): : 1891 - 1891