Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study

被引:8
|
作者
Moorthy, Vikaesh [1 ]
Chen, Jerry Yongqiang [2 ]
Liow, Ming Han Lincoln [2 ]
Chin, Pak Lin [2 ]
Chia, Shi-Lu [2 ]
Lo, Ngai Nung [2 ]
Yeo, Seng Jin [2 ]
机构
[1] Natl Univ Singapore, Yong Loo Lin Sch Med, 1E Kent Ridge Rd,NUHS Tower Block,Level 11, Singapore 119228, Singapore
[2] Singapore Gen Hosp, Dept Orthpaed Surg, Block 6 Level 7,Outram Rd, Singapore 169608, Singapore
关键词
Patient-specific instrumentation; Total knee arthroplasty; Lower limb alignment; Functional outcomes; Patient-reported outcome measures; POSITIONING GUIDES; ALIGNMENT OUTCOMES; IMPROVED ACCURACY; BLOOD-LOSS; CT; REPLACEMENT; MULTICENTER; BENEFIT; SF-36;
D O I
10.1007/s00402-020-03729-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Patient-specific instrumentation (PSI) utilizes three-dimensional imaging to produce total knee arthroplasty cutting jigs which matches patient's native anatomy. However, there are limited mid- to long-term studies examining its clinical efficacy. The aim of this study was to compare functional outcomes of PSI surgery versus conventional TKA surgery at 5-year follow-up. Materials and methods Sixty patients were prospectively recruited into either the MRI-based PSI or conventional TKA group. Functional outcomes were assessed using the Knee Society Function Score (KSFS), Knee Society Knee Score (KSKS) and Oxford Knee Score (OKS), while quality of life was evaluated with the Physical Component Score (PCS) and Mental Component Score (MCS) of Short-Form 36 and compared between the two groups at 5-year follow-up. Results Although the PCS was 7 +/- 3 points better in the PSI group preoperatively (p = 0.017), it became 5 +/- 2 points worse than the conventional group at 5-year follow-up (p = 0.025). As compared to the PSI group, the conventional group showed a significantly greater improvement in PCS at 5 years as compared to before surgery (p = 0.003). There were no significant differences in KSFS, KSKS, OKS or MCS between the two groups. Conclusions PSI TKA did not result in improved functional outcomes or better quality of life when compared to conventional TKA. The additional costs and waiting time associated with PSI are not justifiable and therefore not recommended as an alternative to conventional TKA.
引用
收藏
页码:669 / 674
页数:6
相关论文
共 50 条
  • [21] Patient specific instrumentation versus conventional knee arthroplasty: comparative study
    Vlad Predescu
    Catalin Prescura
    Razvan Olaru
    Liliana Savin
    Paul Botez
    Bogdan Deleanu
    International Orthopaedics, 2017, 41 : 1361 - 1367
  • [22] Patient specific instrumentation versus conventional knee arthroplasty: comparative study
    Predescu, Vlad
    Prescura, Catalin
    Olaru, Razvan
    Savin, Liliana
    Botez, Paul
    Deleanu, Bogdan
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (07) : 1361 - 1367
  • [23] No difference in mid-term survival and clinical outcome between patient-specific and conventional instrumented total knee arthroplasty: a randomized controlled trial
    M. G. M. Schotanus
    B. Boonen
    W. van der Weegen
    H. Hoekstra
    R. van Drumpt
    R. Borghans
    R. Vos
    L. van Rhijn
    N. P. Kort
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1463 - 1468
  • [24] Functional Outcomes and Accuracy of Patient-Specific Instruments for Total Knee Arthroplasty
    Stone, Andrea H.
    Sibia, Udai S.
    MacDonald, James H.
    SURGICAL INNOVATION, 2018, 25 (05) : 470 - 475
  • [25] Patient-specific instrumentation for total knee arthroplasty: a literature review
    Camarda L.
    D’Arienzo A.
    Morello S.
    Peri G.
    Valentino B.
    D’Arienzo M.
    MUSCULOSKELETAL SURGERY, 2015, 99 (1) : 11 - 18
  • [26] Patient-Specific Instrumentation in Total Knee Arthroplasty: What Is the Evidence?
    Szczech, Bartlomiej
    McDermott, James D.
    Issa, Kimona
    Rifai, Aiman
    Festa, Anthony
    Matarese, William A.
    McInerney, Vincent K.
    JOURNAL OF KNEE SURGERY, 2016, 29 (04) : 341 - 345
  • [27] Reliability of Templating with Patient-Specific Instrumentation in Total Knee Arthroplasty
    Issa, Kimona
    Rifai, Aiman
    McGrath, Mike S.
    Callaghan, John J.
    Wright, Craig
    Malkani, Arthur L.
    Mont, Michael A.
    McInerney, Vincent K.
    JOURNAL OF KNEE SURGERY, 2013, 26 (06) : 429 - 433
  • [28] Patient-specific instrumentation makes sense in total knee arthroplasty
    Leon-Munoz, Vicente J.
    Lopez-Lopez, Mirian
    Santonja-Medina, Fernando
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (06) : 489 - 497
  • [29] Total Knee Arthroplasty: Validating The Benefits Of Patient-Specific Instrumentation
    Moore, S.
    Linton, K. N.
    Martin, P.
    Headon, R. J.
    Bennett, D.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2018, 187 : S74 - S75
  • [30] Patient-specific computed tomography based instrumentation in total knee arthroplasty: a prospective randomized controlled study
    Kotela, Andrzej
    Kotela, Ireneusz
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (10) : 2099 - 2107