Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study

被引:8
|
作者
Moorthy, Vikaesh [1 ]
Chen, Jerry Yongqiang [2 ]
Liow, Ming Han Lincoln [2 ]
Chin, Pak Lin [2 ]
Chia, Shi-Lu [2 ]
Lo, Ngai Nung [2 ]
Yeo, Seng Jin [2 ]
机构
[1] Natl Univ Singapore, Yong Loo Lin Sch Med, 1E Kent Ridge Rd,NUHS Tower Block,Level 11, Singapore 119228, Singapore
[2] Singapore Gen Hosp, Dept Orthpaed Surg, Block 6 Level 7,Outram Rd, Singapore 169608, Singapore
关键词
Patient-specific instrumentation; Total knee arthroplasty; Lower limb alignment; Functional outcomes; Patient-reported outcome measures; POSITIONING GUIDES; ALIGNMENT OUTCOMES; IMPROVED ACCURACY; BLOOD-LOSS; CT; REPLACEMENT; MULTICENTER; BENEFIT; SF-36;
D O I
10.1007/s00402-020-03729-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Patient-specific instrumentation (PSI) utilizes three-dimensional imaging to produce total knee arthroplasty cutting jigs which matches patient's native anatomy. However, there are limited mid- to long-term studies examining its clinical efficacy. The aim of this study was to compare functional outcomes of PSI surgery versus conventional TKA surgery at 5-year follow-up. Materials and methods Sixty patients were prospectively recruited into either the MRI-based PSI or conventional TKA group. Functional outcomes were assessed using the Knee Society Function Score (KSFS), Knee Society Knee Score (KSKS) and Oxford Knee Score (OKS), while quality of life was evaluated with the Physical Component Score (PCS) and Mental Component Score (MCS) of Short-Form 36 and compared between the two groups at 5-year follow-up. Results Although the PCS was 7 +/- 3 points better in the PSI group preoperatively (p = 0.017), it became 5 +/- 2 points worse than the conventional group at 5-year follow-up (p = 0.025). As compared to the PSI group, the conventional group showed a significantly greater improvement in PCS at 5 years as compared to before surgery (p = 0.003). There were no significant differences in KSFS, KSKS, OKS or MCS between the two groups. Conclusions PSI TKA did not result in improved functional outcomes or better quality of life when compared to conventional TKA. The additional costs and waiting time associated with PSI are not justifiable and therefore not recommended as an alternative to conventional TKA.
引用
收藏
页码:669 / 674
页数:6
相关论文
共 50 条
  • [1] Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study
    Vikaesh Moorthy
    Jerry Yongqiang Chen
    Ming Han Lincoln Liow
    Pak Lin Chin
    Shi-Lu Chia
    Ngai Nung Lo
    Seng Jin Yeo
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 669 - 674
  • [2] Patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty
    Chan, Warwick Chun-Wang
    Pinder, Elizabeth
    Loeffler, Mark
    JOURNAL OF ORTHOPAEDIC SURGERY, 2016, 24 (02) : 175 - 178
  • [3] The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    Chen, Jerry Yongqiang
    Yeo, Seng Jin
    Yew, Andy Khye Soon
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Chin, Pak Lin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (03) : 630 - 635
  • [4] The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    Jerry Yongqiang Chen
    Seng Jin Yeo
    Andy Khye Soon Yew
    Darren Keng Jin Tay
    Shi-Lu Chia
    Ngai Nung Lo
    Pak Lin Chin
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 630 - 635
  • [5] Contact kinematics of patient-specific instrumentation versus conventional instrumentation for total knee arthroplasty
    Broberg, Jordan S.
    Naudie, Douglas D. R.
    Howard, James L.
    Vasarhelyi, Edward M.
    McCalden, Richard W.
    Teeter, Matthew G.
    KNEE, 2020, 27 (05): : 1501 - 1509
  • [6] Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
    Mehdipour, Soheil
    Qoreishi, Mohamad
    Keipourfard, Ali
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2020, 8 (05): : 625 - 632
  • [7] Accuracy of Patient-Specific Instrumentation Compared With Conventional Instrumentation in Total Knee Arthroplasty
    Jiang, Jin
    Kang, Xin
    Lin, Qiao
    Teng, Yuanjun
    An, Liping
    Ma, Jingling
    Wang, Jing
    Xia, Yayi
    ORTHOPEDICS, 2015, 38 (04) : E305 - E313
  • [8] Patient-specific instrumentation in total knee arthroplasty
    Leon-Munoz, Vicente J.
    Martinez-Martinez, Francisco
    Lopez-Lopez, Mirian
    Santonja-Medina, Fernando
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (07) : 555 - 567
  • [9] Patient-specific instrumentation in total knee arthroplasty
    Mathis, Dominic T.
    Hirschmann, Michael T.
    ARTHROSKOPIE, 2021, 34 (05) : 342 - 350
  • [10] Patient-Specific Instrumentation in Total Knee Arthroplasty
    Jauregui, Julio J.
    Cherian, Jeffrey J.
    Kapadia, Bhaveen H.
    Banerjee, Samik
    Issa, Kimona
    Harwin, Steven F.
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2014, 27 (03) : 177 - 183