An in vitro study of the strain distribution in human femora with anatomical and customised femoral stems

被引:45
|
作者
Ostbyhaug, P. O. [1 ]
Klaksvik, J. [1 ]
Romundstad, P.
Aamodt, A. [1 ]
机构
[1] Univ Trondheim Hosp, Dept Orthopaed Surg, N-7006 Trondheim, Norway
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2009年 / 91B卷 / 05期
关键词
TOTAL HIP-ARTHROPLASTY; HYDROXYAPATITE-ABG HIP; BONE-RESORPTION; PROXIMAL FEMUR; WOLFFS LAW; FOLLOW-UP; DESIGN; FIT; PROSTHESIS; COMPONENTS;
D O I
10.1302/0301-620X.91B5.21749
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hydroxyapatite-coated standard anatomical and customised femoral stems are designed to transmit load to the metaphyseal part of the proximal femur in order to avoid stress shielding and to reduce resorption of bone. In a randomised in vitro study, we compared the changes in the pattern of cortical strain after the insertion of hydroxyapatite-coated standard anatomical and customised stems in 12 pairs of human cadaver femora. A hip simulator reproduced the physiological loads on the proximal femur in single-leg stance and stair-climbing. The cortical strains were measured before and after the insertion of the stems. Significantly higher strain shielding was seen in Gruen zones 7, 6, 5, 3 and 2 after the insertion of the anatomical stem compared with the customised stem. For the anatomical stem, the hoop strains on the femur also indicated that the load was transferred to the cortical bone at the lower metaphyseal or upper diaphyseal part of the proximal femur. The customised stem induced a strain pattern more similar to that of the intact femur than the standard, anatomical stem.
引用
收藏
页码:676 / 682
页数:7
相关论文
共 50 条
  • [41] Stiffness and compactness of morselized grafts during impaction - An in vitro study with human femoral heads
    Bavadekar, A
    Cornu, O
    Godts, B
    Delloye, C
    Van Tomme, J
    Banse, X
    ACTA ORTHOPAEDICA SCANDINAVICA, 2001, 72 (05): : 470 - 476
  • [42] Prediction of human femoral bone strength using ultrasound velocity and BMD: An in vitro study
    Njeh, CF
    Kuo, CW
    Langton, CM
    Atrah, HI
    Boivin, CM
    OSTEOPOROSIS INTERNATIONAL, 1997, 7 (05) : 471 - 477
  • [43] Prediction of Human Femoral Bone Strength Using Ultrasound Velocity and BMD: An In Vitro Study
    C.F. Njeh
    C.W. Kuo
    C.M. Langton
    H.I. Atrah
    C.M. Boivin
    Osteoporosis International, 1997, 7 : 471 - 477
  • [44] Effect of shape and size of supraspinatus tears on rotator cuff strain distribution: an in vitro study
    Santos, Ines
    Pichler, Lieselotte
    Saller, Maximilian M.
    Thorwaechter, Christoph
    Mueller, Julia Gertrud
    Traxler, Hannes
    Pietschmann, Matthias F.
    Tauber, Mark
    Mueller, Peter E.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (02) : E71 - E83
  • [45] Strain rate influence on human cortical bone toughness: A comparative study of four paired anatomical sites
    Gauthier, Remy
    Follet, Helene
    Langer, Max
    Meille, Sylvain
    Chevalier, Jerome
    Rongieras, Frederic
    Peyrin, Francoise
    Mitton, David
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 71 : 223 - 230
  • [46] A Preliminary In Vitro Study of 3D Full-Field Strain Distribution in Human Whole Premolars Using Digital Image Correlation
    Liu, Qing
    Dong, Qianqian
    Wen, Yifeng
    Shi, Baoquan
    MATERIALS, 2022, 15 (06)
  • [47] Does femoral strain distribution coincide with the occurrence of cervical versus trochanteric hip fractures? An experimental finite element study
    Janne E. M. Koivumäki
    Jérôme Thevenot
    Pasi Pulkkinen
    Jukka A. Salmi
    Volker Kuhn
    Eva-Maria Lochmüller
    Thomas M. Link
    Felix Eckstein
    Timo Jämsä
    Medical & Biological Engineering & Computing, 2010, 48 : 711 - 717
  • [48] Does femoral strain distribution coincide with the occurrence of cervical versus trochanteric hip fractures? An experimental finite element study
    Koivumaki, Janne E. M.
    Thevenot, Jerome
    Pulkkinen, Pasi
    Salmi, Jukka A.
    Kuhn, Volker
    Lochmueller, Eva-Maria
    Link, Thomas M.
    Eckstein, Felix
    Jamsa, Timo
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (07) : 711 - 717
  • [49] DISTRIBUTION OF CHROMOSOME ABERRATIONS IN HUMAN LEUKOCYTES - STUDY IN-VIVO AND IN-VITRO
    BOCHKOV, NP
    YAKOVENK.KN
    CHEBOTAR.AN
    FUNESKRA.F
    ZHURKOV, VS
    GENETIKA, 1972, 8 (12): : 160 - 168
  • [50] A QUANTITATIVE IN VITRO STUDY OF CHROMATOGRAPHIC DISTRIBUTION AND IMMUNOGLOBULIN CHARACTERISTICS OF HUMAN BLOCKING ANTIBODY
    LICHTENSTEIN, LM
    HOLTZMAN, NA
    BURNETT, LS
    JOURNAL OF IMMUNOLOGY, 1968, 101 (02): : 317 - +