An in vitro study of the strain distribution in human femora with anatomical and customised femoral stems

被引:45
|
作者
Ostbyhaug, P. O. [1 ]
Klaksvik, J. [1 ]
Romundstad, P.
Aamodt, A. [1 ]
机构
[1] Univ Trondheim Hosp, Dept Orthopaed Surg, N-7006 Trondheim, Norway
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2009年 / 91B卷 / 05期
关键词
TOTAL HIP-ARTHROPLASTY; HYDROXYAPATITE-ABG HIP; BONE-RESORPTION; PROXIMAL FEMUR; WOLFFS LAW; FOLLOW-UP; DESIGN; FIT; PROSTHESIS; COMPONENTS;
D O I
10.1302/0301-620X.91B5.21749
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hydroxyapatite-coated standard anatomical and customised femoral stems are designed to transmit load to the metaphyseal part of the proximal femur in order to avoid stress shielding and to reduce resorption of bone. In a randomised in vitro study, we compared the changes in the pattern of cortical strain after the insertion of hydroxyapatite-coated standard anatomical and customised stems in 12 pairs of human cadaver femora. A hip simulator reproduced the physiological loads on the proximal femur in single-leg stance and stair-climbing. The cortical strains were measured before and after the insertion of the stems. Significantly higher strain shielding was seen in Gruen zones 7, 6, 5, 3 and 2 after the insertion of the anatomical stem compared with the customised stem. For the anatomical stem, the hoop strains on the femur also indicated that the load was transferred to the cortical bone at the lower metaphyseal or upper diaphyseal part of the proximal femur. The customised stem induced a strain pattern more similar to that of the intact femur than the standard, anatomical stem.
引用
收藏
页码:676 / 682
页数:7
相关论文
共 50 条
  • [21] Nerve distribution to the human knee joint: anatomical and immunohistochemical study
    Hirasawa, Y
    Okajima, S
    Ohta, M
    Tokioka, T
    INTERNATIONAL ORTHOPAEDICS, 2000, 24 (01) : 1 - 4
  • [22] Nerve distribution to the human knee joint: anatomical and immunohistochemical study
    Y. Hirasawa
    S. Okajima
    M. Ohta
    T. Tokioka
    International Orthopaedics, 2000, 24 : 1 - 4
  • [23] Number and distribution of nutrient foramina within the femoral neck and their relationship to the retinacula of Weitbrecht: an anatomical study
    Jiong Mei
    Ming Ni
    Guoliang Wang
    Guangyao Jia
    Shiwei Liu
    Xueliang Cui
    Chao Jiang
    Hua Wang
    Yahui Dai
    Kun Quan
    Rui Chen
    Anatomical Science International, 2017, 92 : 91 - 97
  • [24] Number and distribution of nutrient foramina within the femoral neck and their relationship to the retinacula of Weitbrecht: an anatomical study
    Mei, Jiong
    Ni, Ming
    Wang, Guoliang
    Jia, Guangyao
    Liu, Shiwei
    Cui, Xueliang
    Jiang, Chao
    Wang, Hua
    Dai, Yahui
    Quan, Kun
    Chen, Rui
    ANATOMICAL SCIENCE INTERNATIONAL, 2017, 92 (01) : 91 - 97
  • [25] A strain gauge and photoelastic analysis of in vivo strain and in vitro stress distribution in human dental supporting structures
    Asundi, A
    Kishen, A
    ARCHIVES OF ORAL BIOLOGY, 2000, 45 (07) : 543 - 550
  • [26] Anatomical study of the femoral and tibial insertions of the anterolateral and posteromedial bundles of human posterior cruciate ligament
    Takahashi, Masaaki
    Matsubara, Takamasa
    Doi, Mitsuhito
    Suzuki, Daisuke
    Nagano, Akira
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (11) : 1055 - 1059
  • [27] Anatomical study of the femoral and tibial insertions of the anterolateral and posteromedial bundles of human posterior cruciate ligament
    Masaaki Takahashi
    Takamasa Matsubara
    Mitsuhito Doi
    Daisuke Suzuki
    Akira Nagano
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 1055 - 1059
  • [28] Anatomical study of the femoral and tibial insertions of the anteromedial and posterolateral bundles of human anterior cruciate ligament
    Takahashi, M
    Doi, M
    Abe, M
    Suzuki, D
    Nagano, A
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (05): : 787 - 792
  • [29] Strain distribution in the proximal Human femur during in vitro simulated sideways fall
    Zani, Lorenzo
    Erani, Paolo
    Grassi, Lorenzo
    Taddei, Fulvia
    Cristofolini, Luca
    JOURNAL OF BIOMECHANICS, 2015, 48 (10) : 2130 - 2143
  • [30] Stress Distribution in Femoral Stems for Revision Total Knee Arthroplasty with Three Different Materials: A Comparative Finite Element Study
    Posti, Mohammad Hosein Zadeh
    Rajaeirad, Mohadese
    Rafie, Aisan
    Gilakjani, Hasan Asadi
    Khorsandi, Mohammad
    2022 29TH NATIONAL AND 7TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2022, : 87 - 91