Genome detection of dermatophytes Current findings from the external quality assessment test

被引:2
|
作者
Kupsch, C. [1 ]
Graeser, Y. [1 ]
机构
[1] Charite Univ Med Berlin, Inst Mikrobiol & Infekt Immunol, Hindenburgdamm 27, D-12203 Berlin, Germany
来源
HAUTARZT | 2019年 / 70卷 / 08期
关键词
Molecular diagnostics; Polymerase chain reaction; Reagent kits; diagnostic; Trichophyton rubrum; Species diagnosis; POLYMERASE-CHAIN-REACTION; CAUSATIVE FUNGAL AGENTS; REAL-TIME PCR; DIFFERENTIAL-DIAGNOSIS; RAPID DETECTION; IDENTIFICATION; ONYCHOMYCOSIS; ASSAY;
D O I
10.1007/s00105-019-4435-3
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
In addition to morphological diagnostics, molecular methods have become available for the diagnosis of suspected dermatophytoses. Since March 2016, INSTAND e.V., in cooperation with the National Reference Laboratory for Dermatophytes, has provided an external quality assessment (EQA) test for the genome detection of dermatophytes twice a year. More than half of the participants used commercial kits for the analysis of the samples. All kits with a high level of accuracy correctly determined the presence of Trichophyton rubrum or no dermatophytes. In species diagnostics beyond Trichophyton rubrum there are large differences between the kits. These are examined in more detail based on clinical studies and the results of the EQA test.
引用
收藏
页码:627 / 637
页数:11
相关论文
共 50 条
  • [21] Automatic Outlier Detection for Genome Assembly Quality Assessment
    Samak, Taghrid
    Egan, Rob
    Bushnell, Brian
    Gunter, Daniel
    Copeland, Alex
    Wang, Zhong
    2013 IEEE 9TH INTERNATIONAL CONFERENCE ON E-SCIENCE (E-SCIENCE), 2013, : 45 - 52
  • [22] Learning from peer assessment: The role of the external quality assurance multilaboratory thrombophilia test process
    Favaloro, EJ
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2005, 31 (01): : 85 - 89
  • [23] Current practices in antinuclear antibody testing: results from the Belgian External Quality Assessment Scheme
    Van Blerk, Marjan
    Van Campenhout, Christel
    Bossuyt, Xavier
    Duchateau, Jean
    Humbel, Rene
    Servais, Genevieve
    Tomasi, Jean-Paul
    Albert, Adelin
    Coucke, Wim
    Libeer, Jean-Claude
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2009, 47 (01) : 102 - 108
  • [24] EXTERNAL QUALITY ASSESSMENT OF TECHNIQUES FOR THE DETECTION OF DRUGS OF ABUSE IN URINE
    WILSON, JF
    SMITH, BL
    TOSELAND, PA
    WILLIAMS, J
    BURNETT, D
    HIRST, AD
    WATSON, ID
    HORN, AN
    ANNALS OF CLINICAL BIOCHEMISTRY, 1994, 31 : 335 - 342
  • [25] Molecular detection of norovirus: 5 years of external quality assessment
    McCulloch, E.
    Di Lorenzo, C.
    Wallace, P. S.
    JOURNAL OF CLINICAL VIROLOGY, 2015, 70 : S57 - S57
  • [26] External Quality Assessment of Molecular Detection of Ebola Virus in China
    Wang, Guojing
    Sun, Yu
    Zhang, Kuo
    Jia, Tingting
    Hao, Mingju
    Zhang, Dong
    Chang, Le
    Zhang, Lei
    Zhang, Rui
    Lin, Guigao
    Peng, Rongxue
    Li, Jinming
    PLOS ONE, 2015, 10 (07):
  • [27] External quality assessment for the molecular detection of Hepatitis C virus
    Chalker, V. J.
    Rossouw, A.
    Mee, Z.
    Patel, P.
    Vaughan, H.
    James, V. L. A.
    JOURNAL OF CLINICAL VIROLOGY, 2007, 39 (02) : 141 - 144
  • [28] Detection of outliers and establishment of targets in external quality assessment programs
    Qi Zhou
    Li, Shaonan
    Li, Xiaopeng
    Wei Wang
    Wang, Zhiguo
    CLINICA CHIMICA ACTA, 2006, 372 (1-2) : 94 - 97
  • [29] External quality assessment for molecular detection of Ureaplasma urealyticum in China
    Han, Yanxi
    Jiang, Jian
    Ma, Yu
    Chen, Yuqing
    Diao, Zhenli
    Huang, Tao
    Li, Jing
    Feng, Wanyu
    Li, Ziqiang
    Li, Jinming
    Zhang, Rui
    CLINICA CHIMICA ACTA, 2024, 557
  • [30] External quality assessment in molecular immunohematology: the INSTAND proficiency test program
    Flegel, Willy A.
    Chiosea, Ion
    Sachs, Ulrich J.
    Bein, Gregor