Analysis of indoor air parameters in an education building

被引:15
|
作者
Krawczyk, Dorota A. [1 ]
Wadolowska, Bernadetta [2 ]
机构
[1] Bialystok Tech Univ, Dept HVAC Engn, Wiejska 45A, PL-15351 Bialystok, Poland
[2] Bialystok Tech Univ, Wiejska 45A, PL-15351 Bialystok, Poland
关键词
indoor air quality; CO2; air chage rates; temperature; CO2; CONCENTRATION; QUALITY; SCHOOLS; MICROCLIMATE; VENTILATION; CLASSROOMS; ENVIRONMENT; POLLUTANT; OUTDOOR; CLIMATE;
D O I
10.1016/j.egypro.2018.07.038
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Main parameters of IAQ (indoor air quality) could influence people health as well as their ability to learning and work. This research on IAQ was conducted in a classroom of Bialystok University of Technology located in the north-eastern part of Poland. We focused on issues related to indoor temperature, relative humidity, carbon dioxide concentration, air change rates and noise. Indoor temperature was recorded in a range from 23.1 degrees C to 24.9 degrees C, so higher than design temperature set at 20 degrees C or comfort temperature found as average 22 degrees C [1]. On the other hand, relative humidity was slightly lower than recommended minimum 40 % (range 31.7 % to 38.3 %). Moreover, we found that the concentration of carbon dioxide during the experiment was constantly increasing to final 1067 ppm, while the average air exchange rate was 1.5 h(-1). (C) 2018 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:96 / 103
页数:8
相关论文
共 50 条
  • [41] Heterogeneous Photocatalysis Applied to Indoor Building Material: Towards an Improved Indoor Air Quality
    Yu, Q. L.
    Ballari, M. M.
    Brouwers, H. J. H.
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 2836 - 2840
  • [42] Overall uncertainty analysis of zonal indoor air temperature measurement in an in-use office building
    Giraldo-Soto, Catalina
    Mora, Laurent
    Erkoreka, Aitor
    Uriarte, Irati
    Eguia, Pablo
    BUILDING AND ENVIRONMENT, 2022, 219
  • [43] Measurement Analysis of Indoor Parameters for an Indoor Wireless Propagation
    Sobetwa, M.
    Sokoya, O.
    2019 INTERNATIONAL CONFERENCE ON WIRELESS TECHNOLOGIES, EMBEDDED AND INTELLIGENT SYSTEMS (WITS), 2019,
  • [44] Analysis of health impact assessment to outdoor and indoor air pollution in a prototype building in Madrid (Spain)
    San Jose, Roberto
    Perez, Juan L.
    Perez, Libia
    Gonzalez Barras, Rosa M.
    15TH INTERNATIONAL CONFERENCE ON ATMOSPHERIC SCIENCES AND APPLICATIONS TO AIR QUALITY, 2020, 489
  • [45] Analysis of Indoor Thermal Environment and Air-Conditioning Mode of Ventilation in Large Space Building
    Wu, Guozhong
    Xue, Kang
    Wang, Jing
    Li, Dong
    COMPUTER SCIENCE FOR ENVIRONMENTAL ENGINEERING AND ECOINFORMATICS, PT 2, 2011, 159 : 467 - 471
  • [46] At the roots of the energy performance gap: Analysis of monitored indoor air before and after building retrofits
    Vivian, Jacopo
    Carnieletto, Laura
    Cover, Matteo
    De Carli, Michele
    BUILDING AND ENVIRONMENT, 2023, 246
  • [47] Parameters of Indoor Air Quality (IAQ) in Wooden Houses
    Svitak, Martin
    Krontorad, Karel
    Kropacek, Jan
    Hlaskova, Lud'ka
    Solar, Ales
    BIORESOURCES, 2018, 13 (04): : 8222 - 8238
  • [48] EFFECTS OF CLIMATIC PARAMETERS ON FORMALDEHYDE CONCENTRATIONS IN INDOOR AIR
    SALTHAMMER, T
    FUHRMANN, F
    KAUFHOLD, S
    MEYER, B
    SCHWARZ, A
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1995, 5 (02): : 120 - 128
  • [49] Building Energy Saving Techniques and Indoor Air Quality - A Dilemma
    Huynh, C. K.
    INTERNATIONAL JOURNAL OF VENTILATION, 2010, 9 (01) : 93 - 98
  • [50] Indoor air quality audit implementation in a hotel building in Portugal
    Asadi, Ehsan
    Costa, J. J.
    da Silva, Manuel Gameiro
    BUILDING AND ENVIRONMENT, 2011, 46 (08) : 1617 - 1623