Analysis of indoor air parameters in an education building

被引:15
|
作者
Krawczyk, Dorota A. [1 ]
Wadolowska, Bernadetta [2 ]
机构
[1] Bialystok Tech Univ, Dept HVAC Engn, Wiejska 45A, PL-15351 Bialystok, Poland
[2] Bialystok Tech Univ, Wiejska 45A, PL-15351 Bialystok, Poland
关键词
indoor air quality; CO2; air chage rates; temperature; CO2; CONCENTRATION; QUALITY; SCHOOLS; MICROCLIMATE; VENTILATION; CLASSROOMS; ENVIRONMENT; POLLUTANT; OUTDOOR; CLIMATE;
D O I
10.1016/j.egypro.2018.07.038
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Main parameters of IAQ (indoor air quality) could influence people health as well as their ability to learning and work. This research on IAQ was conducted in a classroom of Bialystok University of Technology located in the north-eastern part of Poland. We focused on issues related to indoor temperature, relative humidity, carbon dioxide concentration, air change rates and noise. Indoor temperature was recorded in a range from 23.1 degrees C to 24.9 degrees C, so higher than design temperature set at 20 degrees C or comfort temperature found as average 22 degrees C [1]. On the other hand, relative humidity was slightly lower than recommended minimum 40 % (range 31.7 % to 38.3 %). Moreover, we found that the concentration of carbon dioxide during the experiment was constantly increasing to final 1067 ppm, while the average air exchange rate was 1.5 h(-1). (C) 2018 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:96 / 103
页数:8
相关论文
共 50 条
  • [31] Characterization of Indoor Air Bioaerosols in an Electrical Headquarter Building
    Rocha, C. A.
    Silva, R. J.
    Monzon, A. E.
    Alfonzo, J.
    INDOOR AND BUILT ENVIRONMENT, 2013, 22 (06) : 910 - 919
  • [32] Indoor air quality factors in designing a healthy building
    Spengler, JD
    Chen, QY
    ANNUAL REVIEW OF ENERGY AND THE ENVIRONMENT, 2000, 25 : 567 - 600
  • [33] Building maintenance linked to indoor air quality problems
    不详
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1996, 38 (04): : 28 - 28
  • [34] A Study of Indoor Air Quality in Refurbished Museum Building
    Dzullkiflli, Syahrun Neizam Mohd
    Abdullah, Abd Halid
    Yong, Lee Yee
    Leman, Abdul Mutalib
    Sohu, Samiullah
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2018, 4 (11): : 2596 - 2605
  • [35] Indoor air quality requirements in green building certifications
    Wei, Wenjuan
    Ramalho, Olivier
    Mandin, Corinne
    BUILDING AND ENVIRONMENT, 2015, 92 : 10 - 19
  • [36] Indoor Environmental Parameters Monitoring for Building Automation Systems
    Lita, Joan
    Visan, Daniel Alexandra
    Cioc, Ion Bogdan
    Mazare, Alin Gheorghita
    Teodorescu, Rodica Mihaela
    2016 8TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTERS AND ARTIFICIAL INTELLIGENCE (ECAI), 2016,
  • [38] Statistical analysis of parameters influencing the relationship between outdoor and indoor air quality in schools
    Poupard, O
    Blondeau, P
    Iordache, V
    Allard, F
    ATMOSPHERIC ENVIRONMENT, 2005, 39 (11) : 2071 - 2080
  • [39] Indoor Air Quality Related to Occupancy at an Air-conditioned Public Building
    Ponsoni, Karina
    Goncalves Raddi, Maria Stella
    BRAZILIAN ARCHIVES OF BIOLOGY AND TECHNOLOGY, 2010, 53 (01) : 99 - 103
  • [40] Active Sampling Procedure of Indoor Air Quality to Evaluate Airborne Fungi in Dental Building of Higher Education Institution
    Sarmin, Nurul 'Izzah Mohd
    Lutfi, Nur Hanan Muhd Idris
    Darus, Fairus Muhamad
    Khan, Hasnah Begum Said Gulam
    ENVIRONMENT-BEHAVIOUR PROCEEDINGS JOURNAL, 2021, 6 : 119 - 126