Micromotion of implant-abutment interfaces (IAI) after loading: correlation of finite element analysis with in vitro performances

被引:15
|
作者
Li, Zhi [1 ,2 ]
Gao, Shanshan [1 ]
Chen, Hongyu [1 ]
Ma, Ruiyang [1 ]
Wu, Tingting [1 ]
Yu, Haiyang [1 ]
机构
[1] Sichuan Univ, State Key Lab Oral Dis, Natl Clin Res Ctr Oral Dis, West China Hosp Stomatol, Chengdu, Sichuan, Peoples R China
[2] Aerosp Ctr Hosp, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Dental implants; Finite element analysis; Microleakage; Micromotion; Locked condition; TITANIUM ABUTMENTS; BACTERIAL LEAKAGE; DENTAL IMPLANT; REMOVAL FORCE; CONNECTIONS; ZIRCONIA; COLONIZATION; MICROLEAKAGE; PARAMETERS; COMPONENTS;
D O I
10.1007/s11517-018-1937-6
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Micromotion between IAI affects long-term survival rate of dental implants. The use of practical implants for mechanical test is costly. Finite element analysis (FEA) could test the micron level deformation changes, but whether it reflects the in vitro mechanical performances remains unknown. This study aims to investigate the correlation between IAI micromotion of FEA and in vitro performances. The two-step-two-component FEA method was used to test the relative deformation between IAI for three implant designs (M1, M2, and M3) during torque loading and cyclic oblique loading. The micromotion was divided into directions that perpendicular to (x-axis) and parallel to (y-axis) IAI. In vitro experiments on the micromotion relevant performance of IAI microleakage (tested by toluidine blue releasing with a spectrometer) and IAI locked condition (tested by abutment removal force tests after detaching the central screws) were also conducted for the identical implant systems (G1, G2, and G3). One-way ANOVA and Pearson's correlation tests were performed for data analysis. FEA illustrated that the three implant systems performed different micromotion patterns. Significant differences were found in the IAI microleakage and removal force among the groups. Positive correlations were found between FEA and in vitro outcomes. Therefore, the two-step-two-component FEA method is an appropriate method to evaluate the IAI micromotion after loading.
引用
收藏
页码:1133 / 1144
页数:12
相关论文
共 50 条
  • [21] Implant-Abutment Connection Deformation After Prosthetic Procedures: An In Vitro Study
    Micarelli, Costanza
    Canullo, Luigi
    Iannello, Giuliano
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (03) : 282 - 286
  • [22] Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features
    Cho, Sung-Yong
    Huh, Yun-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 319 - 327
  • [23] Stress Evaluation of Implant-Abutment Connections Under Different Loading Conditions: A 3D Finite Element Study
    Ferreira Koyama Takahashi, Jessica Mie
    Dayrell, Andreza Costa
    Xediek Consani, Rafael Leonardo
    de Arruda Nobilo, Mauro Antonio
    Pessanha Henriques, Guilherme Elias
    Mesquita, Marcelo Ferraz
    Journal of Oral Implantology, 2015, 41 (02) : 133 - 137
  • [24] Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: Three-dimensional finite element analysis
    Yamanishi, Yasufumi
    Yamaguchi, Satoshi
    Imazato, Satoshi
    Nakano, Tamaki
    Yatani, Hirofumi
    DENTAL MATERIALS, 2012, 28 (11) : 26 - 33
  • [25] Effect of Serrating Abutment-Implant Mating Surface on Torque Stability of Implant-Abutment Connection, Before and After Cyclic Loading
    Rezayani, Vida
    Alikhasi, Marzieh
    Monzavi, Abbas
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (06) : 555 - 561
  • [26] Implant deformation and implant-abutment fracture resistance after standardized artificial aging: An in vitro study
    Zhai, Zhihao
    Tamaki, Nakano
    Chen, Yuming
    Shota, Watanabe
    Takashi, Matsuoka
    Shoichi, Ishigaki
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2023, 25 (01) : 107 - 117
  • [27] Stability of Implant-Abutment Connection After Using the Rescue Kit: An In Vitro Study
    Sprenger, Achim
    Gutauskas, Kristupas
    Filippi, Andreas
    Rosentritt, Martin
    Kuehl, Sebastian
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1274 - 1278
  • [28] Biomechanical Repercussions of Bone Resorption Related to Biologic Width: A Finite Element Analysis of Three Implant-Abutment Configurations
    Rodriguez-Ciurana, Xavier
    Vela-Nebot, Xavier
    Segala-Torres, Maribel
    Rodado-Alonso, Carlos
    Mendez-Blanco, Victor
    Mata-Bugueroles, Marta
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2009, 29 (05) : 479 - 488
  • [29] Mechanical Evaluation of an Implant-Abutment Self-Locking Taper Connection: Finite Element Analysis and Experimental Tests
    Sannino, Gianpaolo
    Barlattani, Alberto
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : E17 - E26
  • [30] Microbial Leakage through Three Different Implant-Abutment Interfaces on Morse Taper Implants In Vitro
    Ribeiro, Ricardo Faria
    da Mata, Victor Barboza
    Tomaselli, Lucas de Oliveira
    Simionato, Anselmo Agostinho
    Santos, Emerson de Souza
    Faria, Adriana Claudia Lapria
    Rodrigues, Renata Cristina Silveira
    do Nascimento, Cassio
    DENTISTRY JOURNAL, 2024, 12 (07)