Real time optical immunosensing with flow-through porous alumina membranes

被引:10
|
作者
Alvarez, Jesus [1 ]
Sola, Laura [2 ]
Cretich, Marina [2 ]
Swann, Marcus J. [3 ]
Gylfason, Kristinn B. [4 ]
Volden, Tormod [5 ]
Chiari, Marcella [2 ]
Hill, Daniel [1 ]
机构
[1] Univ Valencia, Inst Mat Sci, Unit Optoelect Mat & Devices, Valencia 46980, Spain
[2] CNR, Ist Chim Riconoscimento Mol, I-20146 Milan, Italy
[3] Farfield Grp Ltd, Biolin Sci, Manchester M22 5TG, Lancs, England
[4] KTH Royal Inst Technol, S-10044 Stockholm, Sweden
[5] Cent Switzerland Ctr, CSEM SA, CH-6055 Alpnach, Switzerland
关键词
Porous alumina; Form birefringence; Polarimetry; Optical biosensing; Copolymer; Quantum dots; BIOSENSORS; SERUM; IGE;
D O I
10.1016/j.snb.2014.06.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Through the presentation of analytical data from bioassay experiments, measured by polarimetry, we demonstrate for the first time a real time immunoassay within a free standing macroporous alumina membrane. The 200 nm nominal pore diameter of the membrane enables flow-through, thereby providing an ideal fluidic platform for the targeted delivery of analytes to bioreceptors immobilized on the pore walls, enabling fast sensing response times and the use of small sample volumes (<100 mu L). For the immunoassay, the pore walls were first coated with the functional copolymer, copoly(DMA-NAS) using a novel coupling process, before immobilization of the allergen protein, beta-lactoglobulin, by spotting. The immuno-assay then proceeded with the binding of the primary and secondary antibody cognates, rabbit anti-beta-lactoglobulin and anti-rabbit IgG respectively. Through the use of streptavidin coated quantum dots as refractive index signal enhancers, a noise floor for individual measurements of 3.7 ng/mL (25 pM) was obtained, with an overall statistical, or formal assay LOD of 33.7 ng/mL (225 pM), for total assay time below 1 h. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:834 / 839
页数:6
相关论文
共 50 条
  • [1] Characterization of porous alumina membranes for efficient, real-time, flow through biosensing
    Sola, Laura
    Alvarez, Jesus
    Cretich, Marina
    Swann, Marcus J.
    Chiari, Marcella
    Hill, Daniel
    JOURNAL OF MEMBRANE SCIENCE, 2015, 476 : 128 - 135
  • [2] Flow-Through Porous Silicon Membranes for Real-Time Label-Free Biosensing
    Zhao, Yiliang
    Gaur, Girija
    Retterer, Scott T.
    Laibinis, Paul E.
    Weiss, Sharon M.
    ANALYTICAL CHEMISTRY, 2016, 88 (22) : 10940 - 10948
  • [3] Real Time Flow-Through Biosensor
    Grimaldi, Immacolata Angelica
    Testa, Genni
    Persichetti, Gianluca
    Bernini, Romeo
    SENSORS, 2018, 431 : 177 - 182
  • [4] FLOW-THROUGH POROUS-ELECTRODES
    ALKIRE, R
    GRACON, B
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1975, 122 (12) : 1594 - 1601
  • [5] Flow-through drying of porous media
    Mahadevan, J
    Sharma, MA
    Yortsos, YC
    AICHE JOURNAL, 2006, 52 (07) : 2367 - 2380
  • [6] FLOW-THROUGH BEDS OF POROUS PARTICLES
    DAVIS, RH
    STONE, HA
    CHEMICAL ENGINEERING SCIENCE, 1993, 48 (23) : 3993 - 4005
  • [7] A real time immunoassay in alumina membranes
    Alvarez, J.
    Sola, L.
    Cretich, M.
    Swann, M. J.
    Gylfasson, K. B.
    Volden, T.
    Chiari, M.
    Hill, D.
    2014 IEEE SENSORS, 2014, : 1760 - 1763
  • [8] Flow-through real time bacterial biosensor for toxic compounds in water
    Eltzov, Evgeni
    Marks, Robert S.
    Voost, Stefan
    Wullings, Bart A.
    Heringa, Minne B.
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 142 (01) : 11 - 18
  • [9] HARDWARE FOR MEASURING FLOW-THROUGH MICROPOROUS MEMBRANES
    ARENAS, A
    VICTORIA, L
    MOLINA, C
    IBANEZ, JA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (11): : 5343 - 5347
  • [10] ANALYSIS OF THE FLOW-THROUGH POROUS TRIELECTRODE REACTOR
    POLLARD, R
    TRAINHAM, JA
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1983, 130 (07) : 1531 - 1535