Estimation of myocardial strain from non-rigid registration and highly accelerated cine CMR

被引:11
|
作者
Langton, Jonathan E. N. [1 ]
Lam, Hoi-Ieng [2 ]
Cowan, Brett R. [2 ]
Occleshaw, Christopher J. [3 ]
Gabriel, Ruvin [3 ]
Lowe, Boris [3 ]
Lydiard, Suzanne [3 ]
Greiser, Andreas [4 ]
Schmidt, Michaela [4 ]
Young, Alistair A. [2 ,5 ]
机构
[1] Auckland Dist Hlth Board, Dept Radiol, Auckland, New Zealand
[2] Univ Auckland, Dept Anat & Med Imaging, Auckland, New Zealand
[3] Auckland Dist Hlth Board, Auckland, New Zealand
[4] Siemens Healthcare GmbH, Erlangen, Germany
[5] Univ Auckland, Fac Med & Hlth Sci, Dept Anat Radiol, 85 Pk Rd, Auckland 1142, New Zealand
来源
关键词
Ventricular function; Strain; Non-rigid registration; Iterative reconstruction; CARDIOVASCULAR MAGNETIC-RESONANCE; FEATURE-TRACKING; VENTRICULAR-FUNCTION; MRI; RECONSTRUCTION; VOLUME;
D O I
10.1007/s10554-016-0978-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Sparsely sampled cardiac cine accelerated acquisitions show promise for faster evaluation of left-ventricular function. Myocardial strain estimation using image feature tracking methods is also becoming widespread. However, it is not known whether highly accelerated acquisitions also provide reliable feature tracking strain estimates. Twenty patients and twenty healthy volunteers were imaged with conventional 14-beat/slice cine acquisition (STD), 4x accelerated 4-beat/slice acquisition with iterative reconstruction (R4), and a 9.2x accelerated 2-beat/slice real-time acquisition with sparse sampling and iterative reconstruction (R9.2). Radial and circumferential strains were calculated using non-rigid registration in the mid-ventricle short-axis slice and inter-observer errors were evaluated. Consistency was assessed using intra-class correlation coefficients (ICC) and bias with Bland-Altman analysis. Peak circumferential strain magnitude was highly consistent between STD and R4 and R9.2 (ICC = 0.876 and 0.884, respectively). Average bias was -1.7 +/- 2.0 %, p < 0.001, for R4 and -2.7 +/- 1.9 %, p < 0.001 for R9.2. Peak radial strain was also highly consistent (ICC = 0.829 and 0.785, respectively), with average bias -11.2 +/- 18.4 %, p < 0.001, for R4 and -15.0 +/- 21.2 %, p < 0.001 for R9.2. STD circumferential strain could be predicted by linear regression from R9.2 with an R-2 of 0.82 and a root mean squared error of 1.8 %. Similarly, radial strain could be predicted with an R-2 of 0.67 and a root mean squared error of 21.3 %. Inter-observer errors were not significantly different between methods, except for peak circumferential strain R9.2 (1.1 +/- 1.9 %) versus STD (0.3 +/- 1.0 %), p = 0.011. Although small systematic differences were observed in strain, these were highly consistent with standard acquisitions, suggesting that accelerated myocardial strain is feasible and reliable in patients who require short acquisition durations.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 50 条
  • [41] Coupled PDEs for non-rigid registration and segmentation
    Unal, G
    Slabaugh, G
    2005 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOL 1, PROCEEDINGS, 2005, : 168 - 175
  • [42] Optimized imaging using non-rigid registration
    Berkels, Benjamin
    Binev, Peter
    Blom, Douglas A.
    Dahmen, Wolfgang
    Sharpley, Robert C.
    Vogt, Thomas
    ULTRAMICROSCOPY, 2014, 138 : 46 - 56
  • [43] Improved non-rigid registration of prostate MRI
    d'Aische, AD
    De Craene, M
    Haker, S
    Weisenfeld, N
    Tempany, C
    Macq, B
    Warfield, SK
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 1, PROCEEDINGS, 2004, 3216 : 845 - 852
  • [44] 1130 Cardiac diastolic function evaluation using a novel method for quantification of cine myocardial deformation analysis (cMDA) based on non-rigid registration
    Himanshu Gupta
    Wei Feng
    Steven G Lloyd
    Thriveni Sanagala
    Louis J Dell'italia
    Thomas S Denney
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [45] Non-rigid registration under isometric deformations
    Huang, Qi-Xing
    Adams, Bart
    Wicke, Martin
    Guibas, Leonidas J.
    COMPUTER GRAPHICS FORUM, 2008, 27 (05) : 1449 - 1457
  • [46] Survey of Non-Rigid Registration Tools in Medicine
    András P. Keszei
    Benjamin Berkels
    Thomas M. Deserno
    Journal of Digital Imaging, 2017, 30 : 102 - 116
  • [47] An Efficient Algorithm for Non-Rigid Image Registration
    Wang, Guanglei
    Lui, Hoi-Shun
    Persson, Mikael
    2010 4TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATION SYSTEMS (ICSPCS), 2010,
  • [48] A Stochastic Approach for Non-Rigid Image Registration
    Kolesov, Ivan
    Lee, Jehoon
    Vela, Patricio
    Tannenbaum, Allen
    IMAGE PROCESSING: ALGORITHMS AND SYSTEMS XI, 2013, 8655
  • [49] Volume reconstruction based on non-rigid registration
    Laboratory of Image Science and Technology, School of Computer Science and Technology, Southeast University, Nanjing Jiangsu Province, 210096, China
    不详
    不详
    不详
    Annu Int Conf IEEE Eng Med Biol Proc, (6535-6538):
  • [50] Summarizing and Visualizing Uncertainty in Non-rigid Registration
    Risholm, Petter
    Pieper, Steve
    Samset, Eigil
    Wells, William M., III
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT II,, 2010, 6362 : 554 - +