Estimation of myocardial strain from non-rigid registration and highly accelerated cine CMR

被引:11
|
作者
Langton, Jonathan E. N. [1 ]
Lam, Hoi-Ieng [2 ]
Cowan, Brett R. [2 ]
Occleshaw, Christopher J. [3 ]
Gabriel, Ruvin [3 ]
Lowe, Boris [3 ]
Lydiard, Suzanne [3 ]
Greiser, Andreas [4 ]
Schmidt, Michaela [4 ]
Young, Alistair A. [2 ,5 ]
机构
[1] Auckland Dist Hlth Board, Dept Radiol, Auckland, New Zealand
[2] Univ Auckland, Dept Anat & Med Imaging, Auckland, New Zealand
[3] Auckland Dist Hlth Board, Auckland, New Zealand
[4] Siemens Healthcare GmbH, Erlangen, Germany
[5] Univ Auckland, Fac Med & Hlth Sci, Dept Anat Radiol, 85 Pk Rd, Auckland 1142, New Zealand
来源
关键词
Ventricular function; Strain; Non-rigid registration; Iterative reconstruction; CARDIOVASCULAR MAGNETIC-RESONANCE; FEATURE-TRACKING; VENTRICULAR-FUNCTION; MRI; RECONSTRUCTION; VOLUME;
D O I
10.1007/s10554-016-0978-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Sparsely sampled cardiac cine accelerated acquisitions show promise for faster evaluation of left-ventricular function. Myocardial strain estimation using image feature tracking methods is also becoming widespread. However, it is not known whether highly accelerated acquisitions also provide reliable feature tracking strain estimates. Twenty patients and twenty healthy volunteers were imaged with conventional 14-beat/slice cine acquisition (STD), 4x accelerated 4-beat/slice acquisition with iterative reconstruction (R4), and a 9.2x accelerated 2-beat/slice real-time acquisition with sparse sampling and iterative reconstruction (R9.2). Radial and circumferential strains were calculated using non-rigid registration in the mid-ventricle short-axis slice and inter-observer errors were evaluated. Consistency was assessed using intra-class correlation coefficients (ICC) and bias with Bland-Altman analysis. Peak circumferential strain magnitude was highly consistent between STD and R4 and R9.2 (ICC = 0.876 and 0.884, respectively). Average bias was -1.7 +/- 2.0 %, p < 0.001, for R4 and -2.7 +/- 1.9 %, p < 0.001 for R9.2. Peak radial strain was also highly consistent (ICC = 0.829 and 0.785, respectively), with average bias -11.2 +/- 18.4 %, p < 0.001, for R4 and -15.0 +/- 21.2 %, p < 0.001 for R9.2. STD circumferential strain could be predicted by linear regression from R9.2 with an R-2 of 0.82 and a root mean squared error of 1.8 %. Similarly, radial strain could be predicted with an R-2 of 0.67 and a root mean squared error of 21.3 %. Inter-observer errors were not significantly different between methods, except for peak circumferential strain R9.2 (1.1 +/- 1.9 %) versus STD (0.3 +/- 1.0 %), p = 0.011. Although small systematic differences were observed in strain, these were highly consistent with standard acquisitions, suggesting that accelerated myocardial strain is feasible and reliable in patients who require short acquisition durations.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 50 条
  • [31] Real time myocardial strain analysis of tagged MR cines using element space non-rigid registration
    NextWindow Ltd, Auckland, New Zealand
    不详
    不详
    Lect. Notes Comput. Sci., PART 4 (385-396):
  • [32] Real Time Myocardial Strain Analysis of Tagged MR Cines Using Element Space Non-rigid Registration
    Li, Bo
    Cowan, Brett R.
    Young, Alistair A.
    COMPUTER VISION - ACCV 2010, PT IV, 2011, 6495 : 385 - +
  • [33] Locally Rigid Globally Non-rigid Surface Registration
    Fujiwara, Kent
    Nishino, Ko
    Takamatsu, Jun
    Zheng, Bo
    Ikeuchi, Katsushi
    2011 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2011, : 1527 - 1534
  • [34] Rigid and non-rigid medical image registration methods
    Dhawan, Atam P.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (2-3) : 200 - 219
  • [35] Tendon strain imaging using non-rigid image registration: a validation study
    Almeida, Nuno M.
    Slagmolen, Pieter
    Barbosa, Daniel
    Scheys, Lennart
    Geukens, Leonie
    Fukagawa, Shingo
    Peers, Koen
    Bellemans, Johan
    Suetens, Paul
    D'Hooge, Jan
    MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320
  • [36] NON-RIGID IMAGE REGISTRATION BASED STRAIN ESTIMATOR FOR INTRAVASCULAR ULTRASOUND ELASTOGRAPHY
    Richards, Michael S.
    Doyley, Marvin M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (03): : 515 - 533
  • [37] Learning from Demonstrations Through the Use of Non-rigid Registration
    Schulman, John
    Ho, Jonathan
    Lee, Cameron
    Abbeel, Pieter
    ROBOTICS RESEARCH, ISRR, 2016, 114 : 339 - 354
  • [38] A non-rigid point cloud registration method based on scene flow estimation
    Deng, Xiaopeng
    Yang, Kai
    Wang, Yong
    Li, Jinlong
    Xie, Liming
    IET IMAGE PROCESSING, 2025, 19 (01)
  • [39] Robust L2E Estimation of Transformation for Non-Rigid Registration
    Ma, Jiayi
    Qiu, Weichao
    Zhao, Ji
    Ma, Yong
    Yuille, Alan L.
    Tu, Zhuowen
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2015, 63 (05) : 1115 - 1129
  • [40] Bayesian multimodality non-rigid image registration via conditional density estimation
    Zhang, J
    Rangarajan, A
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2003, 2732 : 499 - 511