Visual evaluation of kinetic characteristics of PET probe for neuroreceptors using a two-phase graphic plot analysis

被引:2
|
作者
Ito, Hiroshi [1 ,2 ]
Ikoma, Yoko [3 ]
Seki, Chie [1 ]
Kimura, Yasuyuki [1 ]
Kawaguchi, Hiroshi [3 ,4 ]
Takuwa, Hiroyuki [1 ]
Ichise, Masanori [1 ]
Suhara, Tetsuya [1 ]
Kanno, Iwao [1 ]
机构
[1] Natl Inst Radiol Sci, Dept Funct Brain Imaging Res, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[2] Fukushima Med Univ, Dept Radiol & Nucl Med, 1 Hikarigaoka, Fukushima, Fukushima 9601295, Japan
[3] Natl Inst Radiol Sci, Dept Mol Imaging & Theranost, Inage Ku, Chiba 2638555, Japan
[4] Natl Inst Adv Ind Sci & Technol, Human Informat Res Inst, 1-1-1 Higashi, Tsukuba, Ibaraki 3058561, Japan
基金
日本学术振兴会;
关键词
PET; Graphic plot analysis; Receptor; Transporter; POSITRON-EMISSION-TOMOGRAPHY; QUANTITATIVE-ANALYSIS; HUMAN BRAIN; BINDING; RECEPTOR; EQUILIBRIUM;
D O I
10.1007/s12149-017-1155-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives In PET studies for neuroreceptors, tracer kinetics are described by the two-tissue compartment model (2-TCM), and binding parameters, including the total distribution volume (V (T)), non-displaceable distribution volume (V (ND)), and binding potential (BPND), can be determined from model parameters estimated by kinetic analysis. The stability of binding parameter estimates depends on the kinetic characteristics of radioligands. To describe these kinetic characteristics, we previously developed a two-phase graphic plot analysis in which V (ND) and V (T) can be estimated from the x-intercept of regression lines for early and delayed phases, respectively. In this study, we applied this graphic plot analysis to visual evaluation of the kinetic characteristics of radioligands for neuroreceptors, and investigated a relationship between the shape of these graphic plots and the stability of binding parameters estimated by the kinetic analysis with 2-TCM in simulated brain tissue time-activity curves (TACs) with various binding parameters. Methods 90-min TACs were generated with the arterial input function and assumed kinetic parameters according to 2-TCM. Graphic plot analysis was applied to these simulated TACs, and the curvature of the plot for each TAC was evaluated visually. TACs with several noise levels were also generated with various kinetic parameters, and the bias and variation of binding parameters estimated by kinetic analysis were calculated in each TAC. These bias and variation were compared with the shape of graphic plots. Results The graphic plots showed larger curvature for TACs with higher specific binding and slower dissociation of specific binding. The quartile deviations of V (ND) and BPND determined by kinetic analysis were smaller for radioligands with slow dissociation. Conclusions The larger curvature of graphic plots for radioligands with slow dissociation might indicate a stable determination of V (ND) and BPND by kinetic analysis. For investigation of the kinetics of radioligands, such kinetic characteristics should be considered.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 50 条
  • [41] Performance Evaluation and Dimensional Analysis of Multistage Helicoaxial Pump for Two-Phase Flow
    Patil, Abhay
    Gudigopuram, Sujan
    Ayyildiz, Burak
    Delgado, Adolfo
    Morrison, Gerald
    INTERNATIONAL JOURNAL OF TURBOMACHINERY PROPULSION AND POWER, 2019, 4 (03)
  • [42] Kinetic analysis of delignification of cedar wood during organosolv treatment with a two-phase solvent using the unreacted-core model
    Kawamata, Yuki
    Yoshikawa, Takuya
    Aoki, Hiromi
    Koyama, Yoshihito
    Nakasaka, Yuta
    Yoshida, Masayuki
    Masuda, Takao
    Chemical Engineering Journal, 2020, 368 : 71 - 78
  • [43] Influence of probe geometry on the characteristics of optical fiber gas-liquid two-phase flow measurement signals
    Ma, Yu
    Lv, Mingyang
    Zhang, Yangrui
    Zhang, Xu
    Li, Song
    Sun, Weimin
    Lewis, Elfed
    APPLIED OPTICS, 2021, 60 (06) : 1660 - 1666
  • [44] Kinetic analysis of delignification of cedar wood during organosolv treatment with a two-phase solvent using the unreacted-core model
    Kawamata, Yuki
    Yoshikawa, Takuya
    Aoki, Hiromi
    Koyama, Yoshihito
    Nakasaka, Yuta
    Yoshida, Masayuki
    Masuda, Takao
    CHEMICAL ENGINEERING JOURNAL, 2019, 368 : 71 - 78
  • [45] Heat transfer characteristics of a two-phase closed thermosyphon using different working fluids
    Ziapour, Behrooz Mirzaei
    Shaker, Hadi
    HEAT AND MASS TRANSFER, 2010, 46 (03) : 307 - 314
  • [46] Gas-Water Two-Phase Flow Characteristics and Flowback Evaluation for Shale Gas Wells
    Xie, Weiyang
    Wu, Jianfa
    Yang, Xuefeng
    Chang, Cheng
    Zhang, Jian
    WATER, 2022, 14 (10)
  • [47] Heat transfer characteristics of a two-phase closed thermosyphon using different working fluids
    Behrooz Mirzaei Ziapour
    Hadi Shaker
    Heat and Mass Transfer, 2010, 46 : 307 - 314
  • [48] Measurements of liquid-metal two-phase flow by using neutron radiography and electrical conductivity probe
    Saito, Y
    Mishima, K
    Tobita, Y
    Suzuki, T
    Matsubayashi, M
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2005, 29 (03) : 323 - 330
  • [49] Modeling and Simulation Analysis on Mixing Characteristics of Two-Phase Flow Around Spacer Grid
    Xiao, Y.
    Duan, T. C.
    Ren, Quan-Yao
    Zheng, Xiao-Yu
    Zheng, Meiyin
    He, Rui
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [50] Base-scale entropy and energy analysis of flow characteristics of the two-phase flow
    Fan, Chunling
    Fan, Qihua
    Li, Haojie
    SYSTEMS SCIENCE & CONTROL ENGINEERING, 2018, 6 (03): : 262 - 269