Visual evaluation of kinetic characteristics of PET probe for neuroreceptors using a two-phase graphic plot analysis

被引:2
|
作者
Ito, Hiroshi [1 ,2 ]
Ikoma, Yoko [3 ]
Seki, Chie [1 ]
Kimura, Yasuyuki [1 ]
Kawaguchi, Hiroshi [3 ,4 ]
Takuwa, Hiroyuki [1 ]
Ichise, Masanori [1 ]
Suhara, Tetsuya [1 ]
Kanno, Iwao [1 ]
机构
[1] Natl Inst Radiol Sci, Dept Funct Brain Imaging Res, Inage Ku, 4-9-1 Anagawa, Chiba 2638555, Japan
[2] Fukushima Med Univ, Dept Radiol & Nucl Med, 1 Hikarigaoka, Fukushima, Fukushima 9601295, Japan
[3] Natl Inst Radiol Sci, Dept Mol Imaging & Theranost, Inage Ku, Chiba 2638555, Japan
[4] Natl Inst Adv Ind Sci & Technol, Human Informat Res Inst, 1-1-1 Higashi, Tsukuba, Ibaraki 3058561, Japan
基金
日本学术振兴会;
关键词
PET; Graphic plot analysis; Receptor; Transporter; POSITRON-EMISSION-TOMOGRAPHY; QUANTITATIVE-ANALYSIS; HUMAN BRAIN; BINDING; RECEPTOR; EQUILIBRIUM;
D O I
10.1007/s12149-017-1155-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives In PET studies for neuroreceptors, tracer kinetics are described by the two-tissue compartment model (2-TCM), and binding parameters, including the total distribution volume (V (T)), non-displaceable distribution volume (V (ND)), and binding potential (BPND), can be determined from model parameters estimated by kinetic analysis. The stability of binding parameter estimates depends on the kinetic characteristics of radioligands. To describe these kinetic characteristics, we previously developed a two-phase graphic plot analysis in which V (ND) and V (T) can be estimated from the x-intercept of regression lines for early and delayed phases, respectively. In this study, we applied this graphic plot analysis to visual evaluation of the kinetic characteristics of radioligands for neuroreceptors, and investigated a relationship between the shape of these graphic plots and the stability of binding parameters estimated by the kinetic analysis with 2-TCM in simulated brain tissue time-activity curves (TACs) with various binding parameters. Methods 90-min TACs were generated with the arterial input function and assumed kinetic parameters according to 2-TCM. Graphic plot analysis was applied to these simulated TACs, and the curvature of the plot for each TAC was evaluated visually. TACs with several noise levels were also generated with various kinetic parameters, and the bias and variation of binding parameters estimated by kinetic analysis were calculated in each TAC. These bias and variation were compared with the shape of graphic plots. Results The graphic plots showed larger curvature for TACs with higher specific binding and slower dissociation of specific binding. The quartile deviations of V (ND) and BPND determined by kinetic analysis were smaller for radioligands with slow dissociation. Conclusions The larger curvature of graphic plots for radioligands with slow dissociation might indicate a stable determination of V (ND) and BPND by kinetic analysis. For investigation of the kinetics of radioligands, such kinetic characteristics should be considered.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 50 条
  • [21] Analysis of two-phase ceramic composites using micromechanical models
    School of Mechanical and Materials Engineering, University College Dublin, Ireland
    不详
    SW7 2AZ, United Kingdom
    Comput Mater Sci, (318-324):
  • [22] Application of ANN and PCA to two-phase flow evaluation using radioisotopes
    Hanus, Robert
    Zych, Marcin
    Petryka, Leszek
    Swisulski, Dariusz
    Strzcpowicz, Anna
    EXPERIMENTAL FLUID MECHANICS 2016 (EFM16 ), 2017, 143
  • [23] Label-Free Direct Visual Analysis of Hydrolytic Enzyme Activity Using Aqueous Two-Phase System Droplet Phase Transitions
    Lai, David
    Frampton, John P.
    Tsuei, Michael
    Kao, Albert
    Takayama, Shuichi
    ANALYTICAL CHEMISTRY, 2014, 86 (08) : 4052 - 4057
  • [24] Comparison of local interfacial characteristics between vertical upward and downward two-phase flows using a four-sensor optical probe
    Tian, Daogui
    Yan, Changqi
    Sun, Licheng
    Tong, Pan
    Liu, Guoqiang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 77 : 1183 - 1196
  • [25] Study on kinetic characteristics of solid-liquid two-phase in transporting pipeline of natural gas hydrate
    Shang, Liyan
    Zhao, Shanlin
    Pan, Zhen
    Huang, Tenglong
    CHEMICAL, MATERIAL AND METALLURGICAL ENGINEERING III, PTS 1-3, 2014, 881-883 : 1814 - +
  • [26] Analysis of chaos characteristics of gas-liquid two-phase flow noise
    Fang, Lide
    Zeng, Qiaoqiao
    Faraj, Yousef
    Zhao, Ning
    Wei, Zihui
    Li, Xiaoting
    FLOW MEASUREMENT AND INSTRUMENTATION, 2019, 65 : 98 - 109
  • [27] Numerical analysis of the two-phase flow characteristics in vertical downward helical pipe
    Liu, Xianfei
    Zhao, Donghai
    Liu, Yifeng
    Jiang, Shuai
    Xiang, Hongzhi
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 108 : 1947 - 1959
  • [28] Two-phase flow patterns characteristics analysis based on image and conductance sensors
    Wang, Zhenya
    Jin, Ningde
    Wang, Chun
    Wang, Jinxiang
    SEVENTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY: SENSORS AND INSTRUMENTS, COMPUTER SIMULATION, AND ARTIFICIAL INTELLIGENCE, 2008, 7127
  • [29] Order Recurrence Analysis on Characteristics of Gas-liquid Two-phase Flow
    Fan Chunling
    Li Haojie
    2014 33RD CHINESE CONTROL CONFERENCE (CCC), 2014, : 6168 - 6173
  • [30] Analysis of the dynamic characteristics of two-phase flow based on the technology of acoustic emission
    Fang, Lide
    Wen, Zitong
    Zhang, Shitao
    Li, Mingming
    Li, Dan
    Zhang, Yao
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MATERIAL, MECHANICAL AND MANUFACTURING ENGINEERING, 2015, 27 : 1173 - 1176