Evaluation of a lithium formate EPR dosimetry system for dose measurements around 192Ir brachytherapy sources

被引:29
|
作者
Antonovic, Laura [1 ]
Gustafsson, Hakan [1 ]
Carlsson, Gudrun Alm [1 ]
Tedgren, Asa Carlsson [1 ]
机构
[1] Linkoping Univ, Dept Med & Hlth Sci IMH, Fac Hlth Sci, SE-58185 Linkoping, Sweden
关键词
brachytherapy; dosimetry; organic compounds; paramagnetic resonance; phantoms; thermoluminescent dosimeters; MONTE-CARLO DOSIMETRY; DISTRIBUTIONS; ENERGY; TLD;
D O I
10.1118/1.3110068
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dosimetry system using lithium formate monohydrate (HCO2Li center dot H2O) as detector material and electron paramagnetic resonance (EPR) spectroscopy for readout has been used to measure absorbed dose distributions around clinical Ir-192 sources. Cylindrical tablets with diameter of 4.5 mm, height of 4.8 mm, and density of 1.26 g/cm(3) were manufactured. Homogeneity test and calibration of the dosimeters were performed in a 6 MV photon beam. Ir-192 irradiations were performed in a PMMA phantom using two different source models, the GammaMed Plus HDR and the microSelectron PDR-v1 model. Measured absorbed doses to water in the PMMA phantom were converted to the corresponding absorbed doses to water in water phantoms of dimensions used by the treatment planning systems (TPSs) using correction factors explicitly derived for this experiment. Experimentally determined absorbed doses agreed with the absorbed doses to water calculated by the TPS to within +/- 2.9%. Relative standard uncertainties in the experimentally determined absorbed doses were estimated to be within the range of 1.7%-1.3% depending on the radial distance from the source, the type of source (HDR or PDR), and the particular absorbed doses used. This work shows that a lithium formate dosimetry system is well suited for measurements of absorbed dose to water around clinical HDR and PDR Ir-192 sources. Being less energy dependent than the commonly used thermoluminescent lithium fluoride (LiF) dosimeters, lithium formate monohydrate dosimeters are well suited to measure absorbed doses in situations where the energy dependence cannot easily be accounted for such as in multiple-source irradiations to verify treatment plans. Their wide dynamic range and linear dose response over the dose interval of 0.2-1000 Gy make them suitable for measurements on sources of the strengths used in clinical applications. The dosimeter size needs, however, to be reduced for application to single-source dosimetry.
引用
收藏
页码:2236 / 2247
页数:12
相关论文
共 50 条
  • [21] Characterization of microMOSFET detectors for in vivo dosimetry in high-dose-rate brachytherapy with 192Ir
    Ruiz-Arrebola, Samuel
    Fabregat-Borras, Rosa
    Rodriguez, Eduardo
    Fernandez-Montes, Manuel
    Perez-Macho, Mercedes
    Ferri, Maria
    Garcia, Ana
    Cardenal, Juan
    Pacheco, Maria T.
    Anchuelo, Javier
    Tornero-Lopez, Ana M.
    Prada, Pedro J.
    Guirado, Damian
    [J]. MEDICAL PHYSICS, 2020, 47 (05) : 2242 - 2253
  • [22] Film dosimetry calibration method for pulsed-dose-rate brachytherapy with an 192Ir source
    Schwob, Nathan
    Orion, Itzhak
    [J]. MEDICAL PHYSICS, 2007, 34 (05) : 1678 - 1683
  • [23] Dosimetry Parameters of the IRH10 192Ir High Dose Rate Brachytherapy Source
    Yi, Chul-Young
    Chun, Kook Jin
    Hah, Suck-Ho
    Kim, Hyun-Moon
    Lim, Chunil
    [J]. JOURNAL OF RADIATION RESEARCH, 2010, 51 (04) : 485 - 492
  • [24] Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Sakelliou, L
    Sandilos, P
    Antypas, C
    Vlachos, L
    Koutsouveli, E
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 1975 - 1984
  • [25] Comparison of calibration procedures for 192IR high-dose-rate brachytherapy sources
    Baltas, D
    Geramani, K
    Ioannidis, GT
    Hierholz, K
    Rogge, B
    Kolotas, C
    Müller-Sievers, K
    Milickovic, N
    Kober, B
    Zamboglou, N
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (03): : 653 - 661
  • [26] Measurement of rectum dose by in vivo alanine/ESR dosimetry in gynecological 192Ir HDR brachytherapy
    Bravo-Miranda, Carlos
    Rech, Amanda Burg
    Oliveira, Harley Francisco
    Bertucci, Edenyse
    Cordova-Fraga, Teodoro
    Baffa, Oswaldo
    [J]. RADIATION MEASUREMENTS, 2015, 75 : 45 - 52
  • [27] Comparison of 3D dose distributions for HDR 192Ir brachytherapy sources with normoxic polymer gel dosimetry and treatment planning system
    Senkesen, Oznur
    Tezcanli, Evrim
    Buyuksarac, Bora
    Ozbay, Ismail
    [J]. MEDICAL DOSIMETRY, 2014, 39 (03) : 266 - 271
  • [28] Gafchromic film dosimetry of a new HDR 192Ir brachytherapy source
    Ayoobian, Navid
    Asl, Akbar Sarabi
    Poorbaygi, Hosein
    Javanshir, Mohammad Reza
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 194 - 205
  • [29] Dosimetric characteristics of 192Ir sources used in interstitial brachytherapy
    Ghiassi-Nejad, M
    Jafarizadeh, M
    Ahmadian-Pour, MR
    Ghahramani, AR
    [J]. APPLIED RADIATION AND ISOTOPES, 2001, 55 (02) : 189 - 195
  • [30] A novel absorbed dose standard for the calibration of 192Ir sources used in high dose rate brachytherapy
    D'Arienzo, M.
    Guerra, A. S.
    Loreti, S.
    Caporali, C.
    Pimpinella, M.
    Bolzan, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S146 - S147