New step-wedge for the volumetric measurement of mammographic density

被引:0
|
作者
Diffey, Jennifer [1 ]
Hufton, Alan
Astley, Susan
机构
[1] Christie Hosp, NW Med Phys, Manchester N20 4BX, Lancs, England
[2] Univ Manchester, Div Imaging Sci & Biomed Engn, Manchester M13 9PT, Lancs, England
来源
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The volume of dense breast tissue can be calculated from an x-ray mammograin by imaging a calibrated step-wedge alongside the breast and determining the compressed breast thickness. Previously published work used a step-wedge made of PTFE with a maximum height of 35mm, length 175mm and width 15mm. Although fulfilling all theoretical requirements, it can be difficult to find space on the film for a large step-wedge when examining bigger breasts. Furthermore, the step-wedge is lead-lined, making it heavy and difficult to attach to the bucky. A more compact aluminium step-wedge has been designed to overcome these limitations, and experiments have been carried out on a prototype to evaluate its performance. Initial results show that the maximum and minimum heights of the prototype step-wedge are inadequate to sufficiently cover the range of optical densities within a breast image at the higher and lower exposures required for 6cm and 2cm Perspex (> 200mAs and < 40mAs respectively). However, the step increment appears to be satisfactory. Analysis of the mean pixel value and standard deviation within Regions of Interest of varying size and position indicates an optimum step length of 3mm. A new step-wedge has been constructed with an improved specification informed by the evaluation of the prototype.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] An in-house step-wedge phantom for the calibration of pixel values in CT localizer radiographs for water-equivalent diameter measurement
    Rif'ah, Sitti M.
    Anam, Choirul
    Sutanto, Heri
    Asiah, Rin H.
    Cholid, Heryani
    Dougherty, Geoff
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2023, 29 (01): : 50 - 57
  • [22] EM Estimation of the X-Ray Spectrum With a Genetically Optimized Step-Wedge Phantom
    Li, Mengzhou
    Fan, Feng-Lei
    Cong, Wenxiang
    Wang, Ge
    [J]. FRONTIERS IN PHYSICS, 2021, 9
  • [23] EM Estimation of the X-Ray Spectrum With a Genetically Optimized Step-Wedge Phantom
    Li, Mengzhou
    Fan, Feng-Lei
    Cong, Wenxiang
    Wang, Ge
    [J]. Frontiers in Physics, 2021, 9
  • [24] THE ACCURACY OF AN X-RAY-FILM QUALITY-ASSURANCE STEP-WEDGE TEST
    BLOXOM, RM
    MANSONHING, LR
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1986, 62 (04): : 449 - 458
  • [25] The Effect of Weight Change on Volumetric Measures of Mammographic Density
    Hart, V
    Reeves, K. W.
    Sturgeon, S. R.
    Reich, N. G.
    Sievert, L. L.
    Kerli-Kowske, K.
    Ma, L.
    Shepherd, J.
    Tice, J.
    Sprague, B. L.
    [J]. CANCER EPIDEMIOLOGY BIOMARKERS & PREVENTION, 2015, 24 (04) : 761 - 761
  • [26] Agreement of Mammographic Measures of Volumetric Breast Density to MRI
    Wang, Jeff
    Azziz, Ania
    Fan, Bo
    Malkov, Serghei
    Klifa, Catherine
    Newitt, David
    Yitta, Silaja
    Hylton, Nola
    Kerlikowske, Karla
    Shepherd, John A.
    [J]. PLOS ONE, 2013, 8 (12):
  • [27] An alternative approach to measuring volumetric mammographic breast density
    Tromans, Christopher
    Brady, Michael
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2006, 4046 : 26 - 33
  • [28] Photon-counting detector step-wedge calibration enabling water and iodine material decomposition
    Rodesch, Pierre -Antoine
    Richtsmeier, Devon
    Murphy, Kevin
    Iniewski, Kris
    Bazalova-Carter, Magdalena
    [J]. JOURNAL OF INSTRUMENTATION, 2024, 19 (05):
  • [29] The RAGE project: a step-wedge implementation of rapid access gastrointestinal endoscopy (RAGE) services in Melbourne
    Emery, Jon
    Kyriakides, Mary
    Chondros, Patty
    Moss, Alan
    [J]. ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2018, 14 : 67 - 67
  • [30] Using Volumetric Breast Density to Quantify the Potential Masking Risk of Mammographic Density
    Destounis, Stamatia
    Johnston, Lisa
    Highnam, Ralph
    Arieno, Andrea
    Morgan, Renee
    Chan, Ariane
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (01) : 222 - 227