Photon-counting detector step-wedge calibration enabling water and iodine material decomposition

被引:0
|
作者
Rodesch, Pierre -Antoine [1 ]
Richtsmeier, Devon [1 ]
Murphy, Kevin [1 ]
Iniewski, Kris [2 ]
Bazalova-Carter, Magdalena [1 ]
机构
[1] Univ Victoria, Dept Phys & Astron, 3800 Finnerty Rd, Victoria, BC V8W2Y2, Canada
[2] Redlen Technol, 1763 Sean Hts, Saanichton, BC V8M 1X6, Canada
来源
JOURNAL OF INSTRUMENTATION | 2024年 / 19卷 / 05期
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
Computerized Tomography (CT) and Computed Radiography (CR); Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); CT; EFFICIENT; ESTIMATOR;
D O I
10.1088/1748-0221/19/05/P05030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Photon -counting detector computed tomography (PCD-CT) has demonstrated improvements in conventional image quality compared to energy integrating detector (EID) CT. PCD-CT has the advantage of being able to operate in conventional and spectral mode simultaneously by sorting photons according to selected energy thresholds. However, to reconstruct spectral images PCD-CT requires extensive calibration and specifically fine-tuning a spectral response. This response is then used to perform material decomposition (MD). We propose a step -wedge phantom made of water and iodine to calibrate a prototype PCD-CT system. Four methods were tested and compared based on calibration accuracy and CT image quality. The exhaustive PCD response was not well calibrated, but a reduced model was defined that was able to perform accurate water/iodine MD and to reduce the ring artifact intensity. The impact of the number of energy bins (from two to seven) was also studied. The number of bins did not affect the spectral accuracy. However, compared to the two energy bin configuration, the seven bin configuration decreased the noise by 10% and 15% in the water and iodine maps, respectively. The model was tested on ex -vivo tissue samples injected with iodine to demonstrate the results of the water/iodine MD on biological materials.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Photon-Counting Detector Calibration with Pulse Pile-Up Correction Using Transmission Measurements of Step-Wedge Phantom
    Sidky, E.
    Paul, E.
    Phillips, J.
    Schmidt, T.
    Pan, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E547 - E547
  • [2] Calibration methods influence quantitative material decomposition in photon-counting spectral CT
    Curtis, Tyler E.
    Roeder, Ryan K.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [3] Improvement of three-material decomposition in spectral mammography with a photon-counting detector
    Lee, Minjae
    Kim, Hyemi
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 81 (02) : 91 - 100
  • [4] Improvement of three-material decomposition in spectral mammography with a photon-counting detector
    Minjae Lee
    Hyemi Kim
    Journal of the Korean Physical Society, 2022, 81 : 91 - 100
  • [5] Photon-Counting CT Material Decomposition in Bone Imaging
    Bhattarai, Abhisek
    Tanaka, Ray
    Yeung, Andy Wai Kan
    Vardhanabhuti, Varut
    JOURNAL OF IMAGING, 2023, 9 (10)
  • [6] Uniformity Correction in Photon-counting X-ray Detector Based on Basis Material Decomposition
    Wang, Xiaolan
    He, Xin
    Taguchi, Katsuyuki
    Patt, Bradley E.
    Wagenaar, Douglas J.
    Frey, Eric C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4168 - +
  • [7] Influence of Threshold Calibration On CT Image Quality of a Photon-Counting Detector
    Rodesch, P.
    Richtsmeier, D.
    Zalavari, L.
    Bazalova-Carter, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E174 - E174
  • [8] High accuracy photon-counting detector calibration and independent verification of a correlated-photon calibration technique
    Polyakov, Sergey V.
    Migdall, Alan L.
    2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 103 - +
  • [9] Image performance of photon-counting imaging detector with wedge-and-strip anode
    He, Ling-Ping
    Ni, Qi-Liang
    Li, Min
    Liu, Shi-Jie
    Chen, Bo
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2009, 17 (11): : 2699 - 2704
  • [10] Material Decomposition in Photon-Counting CT: A Deep Learning Approach Driven by Detector Physics and ASIC Modeling
    Yu, Xiaopeng
    Wu, Qianyu
    Qin, Wenhui
    Zhong, Tao
    Su, Mengqing
    Ma, Jinglu
    Zhang, Yikun
    Ji, Xu
    Quan, Guotao
    Chen, Yang
    Du, Yanfeng
    Lai, Xiaochun
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2024, PT VII, 2024, 15007 : 457 - 466