Femtosecond laser-assisted corneal transplantation with a low-energy, liquid-interface system

被引:6
|
作者
Liu, Yu-Chi [1 ,2 ,3 ,4 ]
Morales-Wong, Fernando [1 ,3 ,5 ]
Patil, Moushmi [3 ]
Han, Sang Beom [6 ]
Lwin, Nyein C. [1 ]
Teo, Ericia Pei Wen [1 ]
Ang, Heng Pei [1 ]
Yussof, Nur Zah M. [1 ]
Mehta, Jodhbir S. [1 ,2 ,3 ,4 ]
机构
[1] Singapore Eye Res Inst, Tissue Engn & Cell Therapy Grp, 20 Coll Rd,Discovery Tower,Level 6, Singapore 169856, Singapore
[2] Singapore Eye Res Inst, Cornea & Refract Surg Grp, Singapore, Singapore
[3] Singapore Natl Eye Ctr, Cornea & External Eye Dis, Singapore, Singapore
[4] Duke NUS Grad Med Sch, Ophthalmol Acad Clin Program, Singapore, Singapore
[5] Autonomous Univ Nuevo Leon, Univ Hosp Dr Jose Eleuterio Gonzalez, Fac Med, San Nicolas De Los Garza, Nuevo Leon, Mexico
[6] Kangwon Natl Univ, Kangwon Natl Univ Hosp, Dept Ophthalmol, Sch Med, Chuncheon Si, South Korea
关键词
INTRAOCULAR-PRESSURE; PENETRATING KERATOPLASTY; CONJUNCTIVAL AUTOGRAFT; MICROKERATOME; CAPSULOTOMY; OUTCOMES; SURGERY;
D O I
10.1038/s41598-022-11461-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Femtosecond laser-assisted keratoplasty has been proposed as a treatment option for corneal transplantation. In this study, we investigated and compared the outcomes of Ziemer Z8 femtosecond laser (FSL)-assisted penetrating keratoplasty (PK) using a liquid interface versus flat interface. Thirty fresh porcine eyes underwent FSL-assisted PK with the Z8 using different levels of energies (30%, 90% or 150%) and different interfaces (liquid or flat). The real-time intraocular pressure (IOP) changes, incision geometry, corneal endothelial damage, as well as the accuracy of laser cutting and tissue reaction, were performed and compared. We found that the overall average IOP at all laser trephination stages was significantly higher with the flat interface, regardless of the energy used (68.9 +/- 15.0 mmHg versus 46.1 +/- 16.6 mmHg; P < 0.001). The overall mean laser-cut angle was 86.2o +/- 6.5o and 88.2o +/- 1.0o, for the liquid and flat platform respectively, indicating minimal deviation from the programmed angle of 90o. When high energy (150%) was used, the endothelial denuded area was significantly greater with the flat interface than with liquid interface (386.1 +/- 53.6 mm(2) versus 139.0 +/- 10.4 mm(2)P = 0.02). The FSL cutting did not cause obvious tissue reaction alongside the laser cut on histological evaluation. The results indicated a liquid interface is the preferable choice in FSL-assisted corneal transplantation.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Femtosecond laser-assisted intrastromal arcuate keratotomy to reduce corneal astigmatism
    Rueckl, Theresa
    Dexl, Alois K.
    Bachernegg, Alexander
    Reischl, Veronika
    Riha, Wolfgang
    Ruckhofer, Josef
    Binder, Perry S.
    Grabner, Guenther
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (04): : 528 - 538
  • [32] Posterior Corneal Surface Stability after Femtosecond Laser-Assisted Keratomileusis
    Cagini, Carlo
    Messina, Marco
    Lupidi, Marco
    Piccinelli, Francesco
    Fiore, Tito
    Fruttini, Daniela
    Spadea, Leopoldo
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [33] Femtosecond Laser-Assisted Lamellar Keratectomy for Anterior Corneal Dystrophies Reply
    Steger, Bernhard
    Romano, Vito
    Kaye, Stephen B.
    CORNEA, 2016, 35 (03) : E8 - E8
  • [34] Femtosecond laser-assisted corneal flap cuts: Morphology, accuracy, and histopathology
    Holzer, Mike P.
    Rabsilber, Tanja M.
    Auffarth, Gerd U.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (07) : 2828 - 2831
  • [35] Femtosecond laser-assisted cataract surgery after corneal refractive surgery
    Hyunmin Ahn
    Ikhyun Jun
    Kyoung Yul Seo
    Eung Kweon Kim
    Tae-im Kim
    Scientific Reports, 12
  • [36] Femtosecond laser-assisted Bowman layer transplantation for advanced keratoconus
    Goncalves, Thiago Barbosa
    Forseto, Adriana dos Santos
    Martins, Anderson de Lima
    Pereira, Nicolas Cesario
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (02) : 697 - 703
  • [37] Low-energy and high-frequency femtosecond laser in the production of donor corneal lamellae
    Victor, Gustavo
    Nose, Walton
    Sousa, Sidney
    Alves, Milton
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [38] Development of interface haze after femtosecond laser-assisted in situ keratomileusis with accelerated corneal crosslinking: a case series
    Hongbo Yin
    Lixiang Wang
    Rui Gong
    Xiaolan Zhang
    Ke Ma
    International Ophthalmology, 2023, 43 : 4333 - 4342
  • [39] Development of interface haze after femtosecond laser-assisted in situ keratomileusis with accelerated corneal crosslinking: a case series
    Yin, Hongbo
    Wang, Lixiang
    Gong, Rui
    Zhang, Xiaolan
    Ma, Ke
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (11) : 4333 - 4342
  • [40] Interface quality of different corneal lamellar-cut depths for femtosecond laser-assisted lamellar anterior keratoplasty
    Zhang, Chenxing
    Bald, Matthew
    Tang, Maolong
    Li, Yan
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (04): : 827 - 835