Femtosecond laser-assisted corneal transplantation with a low-energy, liquid-interface system

被引:6
|
作者
Liu, Yu-Chi [1 ,2 ,3 ,4 ]
Morales-Wong, Fernando [1 ,3 ,5 ]
Patil, Moushmi [3 ]
Han, Sang Beom [6 ]
Lwin, Nyein C. [1 ]
Teo, Ericia Pei Wen [1 ]
Ang, Heng Pei [1 ]
Yussof, Nur Zah M. [1 ]
Mehta, Jodhbir S. [1 ,2 ,3 ,4 ]
机构
[1] Singapore Eye Res Inst, Tissue Engn & Cell Therapy Grp, 20 Coll Rd,Discovery Tower,Level 6, Singapore 169856, Singapore
[2] Singapore Eye Res Inst, Cornea & Refract Surg Grp, Singapore, Singapore
[3] Singapore Natl Eye Ctr, Cornea & External Eye Dis, Singapore, Singapore
[4] Duke NUS Grad Med Sch, Ophthalmol Acad Clin Program, Singapore, Singapore
[5] Autonomous Univ Nuevo Leon, Univ Hosp Dr Jose Eleuterio Gonzalez, Fac Med, San Nicolas De Los Garza, Nuevo Leon, Mexico
[6] Kangwon Natl Univ, Kangwon Natl Univ Hosp, Dept Ophthalmol, Sch Med, Chuncheon Si, South Korea
关键词
INTRAOCULAR-PRESSURE; PENETRATING KERATOPLASTY; CONJUNCTIVAL AUTOGRAFT; MICROKERATOME; CAPSULOTOMY; OUTCOMES; SURGERY;
D O I
10.1038/s41598-022-11461-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Femtosecond laser-assisted keratoplasty has been proposed as a treatment option for corneal transplantation. In this study, we investigated and compared the outcomes of Ziemer Z8 femtosecond laser (FSL)-assisted penetrating keratoplasty (PK) using a liquid interface versus flat interface. Thirty fresh porcine eyes underwent FSL-assisted PK with the Z8 using different levels of energies (30%, 90% or 150%) and different interfaces (liquid or flat). The real-time intraocular pressure (IOP) changes, incision geometry, corneal endothelial damage, as well as the accuracy of laser cutting and tissue reaction, were performed and compared. We found that the overall average IOP at all laser trephination stages was significantly higher with the flat interface, regardless of the energy used (68.9 +/- 15.0 mmHg versus 46.1 +/- 16.6 mmHg; P < 0.001). The overall mean laser-cut angle was 86.2o +/- 6.5o and 88.2o +/- 1.0o, for the liquid and flat platform respectively, indicating minimal deviation from the programmed angle of 90o. When high energy (150%) was used, the endothelial denuded area was significantly greater with the flat interface than with liquid interface (386.1 +/- 53.6 mm(2) versus 139.0 +/- 10.4 mm(2)P = 0.02). The FSL cutting did not cause obvious tissue reaction alongside the laser cut on histological evaluation. The results indicated a liquid interface is the preferable choice in FSL-assisted corneal transplantation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Effect of femtosecond laser-assisted cataract surgery on the corneal endothelium
    Abell, Robin G.
    Kerr, Nathan M.
    Howie, Allister R.
    Kamal, Mohd A. A. Mustaffa
    Allen, Penelope L.
    Vote, Brendan J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (11): : 1777 - 1783
  • [22] Femtosecond laser-assisted implantation of corneal stroma lenticule for keratoconus
    Adriano Fasolo
    Alice Galzignato
    Emilio Pedrotti
    Chiara Chierego
    Tiziano Cozzini
    Erika Bonacci
    Giorgio Marchini
    International Ophthalmology, 2021, 41 : 1949 - 1957
  • [23] Femtosecond Laser-Assisted Intra-Corneal Drug Delivery
    Pallikaris, Ioannis G.
    Kymionis, George D.
    Plaka, Argyro D.
    Binder, Perry S.
    Kontadakis, Georgios A.
    Tsoulnaras, Konstantinos I.
    SEMINARS IN OPHTHALMOLOGY, 2015, 30 (5-6) : 457 - 461
  • [24] Femtosecond laser-assisted implantation of corneal stroma lenticule for keratoconus
    Fasolo, Adriano
    Galzignato, Alice
    Pedrotti, Emilio
    Chierego, Chiara
    Cozzini, Tiziano
    Bonacci, Erika
    Marchini, Giorgio
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (05) : 1949 - 1957
  • [25] Femtosecond Laser-Assisted Lamellar Keratectomy for Anterior Corneal Dystrophies
    Arora, Tarun
    Arora, Supriya
    Sharma, Vijay
    CORNEA, 2016, 35 (03) : E7 - E8
  • [26] ON THE POSSIBILITY OF LASER-ASSISTED PRODUCTION AND DETECTION OF LOW-ENERGY NEUTRINO BEAMS
    Eerkens, Jeff W.
    NATURE OF LIGHT: WHAT ARE PHOTONS? V, 2013, 8832
  • [27] Femtosecond Laser-assisted Lens Surgery with Low-energy Pulse versus Conventional Phacoemulsification for Presbyopia Correction: An Intraindividual Study
    Salgado, Ramiro M. P. C.
    Torres, Paulo F. A. A. S.
    Marinho, Antonio A. P.
    OPEN OPHTHALMOLOGY JOURNAL, 2021, 15 : 43 - 53
  • [28] Pupil Status with Low-Energy Femtosecond Laser-Assisted Cataract Surgery versus Conventional Phacoemulsification: An Intraindividual Comparative Study
    Salgado, Ramiro
    Torres, Paulo F.
    Marinho, Antonio
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 331 - 339
  • [29] Femtosecond Laser-Assisted Small Incision Sutureless Intrastronnal Lamellar Keratoplasty (SILK) for Corneal Transplantation in Keratoconus
    Pradhan, Kishore R.
    Reinstein, Dan Z.
    Vida, Ryan S.
    Archer, Timothy J.
    Dhungel, Shashwat
    Dhungana, Purushottam
    Carp, Glenn, I
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (10) : 663 - +
  • [30] Femtosecond laser-assisted cataract surgery after corneal refractive surgery
    Ahn, Hyunmin
    Jun, Ikhyun
    Seo, Kyoung Yul
    Kim, Eung Kweon
    Kim, Tae-im
    SCIENTIFIC REPORTS, 2022, 12 (01)