Development and validation of a sensitive liquid chromatographic-tandem mass spectrometric method for the simultaneous analysis of granisetron and 7-hydroxy granisetron in human plasma and urine samples: application in a clinical pharmacokinetic study in pregnant subject

被引:8
|
作者
Zhao, Yang [1 ]
Chen, Hui-Jun [1 ,2 ]
Caritis, Steve [3 ,4 ]
Venkataramanan, Raman [1 ,3 ,5 ,6 ,7 ]
机构
[1] Univ Pittsburgh, Sch Pharm, Dept Pharmaceut Sci, Pittsburgh, PA 15261 USA
[2] Tsinghua Univ, Sch Med, Beijing 100084, Peoples R China
[3] Magee Womens Res Inst, Pittsburgh, PA USA
[4] Magee Womens Hosp, Dept Obstet & Gynecol, Pittsburgh, PA USA
[5] Univ Pittsburgh, Sch Med, Dept Pathol, Pittsburgh, PA USA
[6] Thomas Starzl Transplantat Inst, Pittsburgh, PA USA
[7] McGovern Inst Regenerat Med, Pittsburgh, PA USA
关键词
LC-MS/MS; granisetron; 7-hydroxy granisetron; plasma; urine; NON-INFERIORITY TRIAL; DOUBLE-BLIND; INTRAVENOUS GRANISETRON; POSTOPERATIVE NAUSEA; CANCER-PATIENTS; MG; CHEMOTHERAPY; PREVENTION; FLUORESCENCE; METABOLISM;
D O I
10.1002/bmc.3530
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatography-tandem mass spectrometric method for the quantification of granisetron and its major metabolite, 7-hydroxy granisetron in human plasma and urine samples was developed and validated. Respective stable isotopically labeled granisetron and 7-hydroxy granisetron were used as internal standards (IS). Chromatography was performed using an Xselect HSS T3 analytical column with a mobile phase of 20% acetonitrile in water (containing 0.2 mM ammonium formate and 0.14% formic acid, pH 4) delivered in an isocratic mode. Tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used for quantification. The standard curves were linear in the concentration ranges of 0.5-100 ng/mL for granisetron and 0.1-100 ng/mL for 7-hydroxy granisetron in human plasma samples, and 2-2000 ng/mL for granisetron and 2-1000 ng/mL for 7-hydroxy granisetron in human urine samples, respectively. The accuracies were >85% and the precision as determined by the coefficient of variations was <10%. No significant matrix effects were observed for granisetron or 7-hydroxy granisetron in either plasma or urine samples. Granisetron was stable under various storage and experimental conditions. This validated method was successfully applied to a pharmacokinetic study after intravenous administration of 1 mg granisetron to a pregnant subject. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 50 条
  • [31] Development, validation of liquid chromatography-tandem mass spectrometry method for simultaneous determination of rosuvastatin and metformin in human plasma and its application to a pharmacokinetic study
    Kumar, P. Pavan
    Murthy, T. E. G. K.
    Rao, M. V. Basaveswara
    JOURNAL OF ADVANCED PHARMACEUTICAL TECHNOLOGY & RESEARCH, 2015, 6 (03) : 118 - 124
  • [32] A high-performance liquid chromatography-tandem mass spectrometry method coupled with protein precipitation for determination of granisetron in human plasma and its application to a comparative pharmacokinetic study
    Zhou, Ying
    Jiang, Ji
    Hu, Pei
    Wang, Hongyun
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (12) : 1597 - 1600
  • [33] Development and validation of a sensitive liquid chromatography/tandem mass spectrometry method for the determination of raddeanin A in rat plasma and its application to a pharmacokinetic study
    Liu, Yinhui
    Ma, Bo
    Zhang, Qi
    Ying, Hanjie
    Li, Jing
    Xu, Qiuyu
    Wu, Di
    Wang, Yonglu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 912 : 16 - 23
  • [34] The development and validation of a method for quantifying olanzapine in human plasma by liquid chromatography tandem mass spectrometry and its application in a pharmacokinetic study
    Tavares Cavalcanti Bedor, Noely Camila
    Galindo Bedor, Danilo Cesar
    Miranda de Sousa, Carlos Eduardo
    Bonifacio, Felipe Nunes
    Castelo Branco, Daniel da Mota
    Leal, Leila Bastos
    de Santana, Davi Pereira
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2015, 42 (03): : 305 - 313
  • [35] A rapid and sensitive liquid chromatography–tandem mass spectrometric method for the determination of hederasaponin B in rat plasma: Application to a pharmacokinetic study
    Jiaxin Liu
    Xueyan Yang
    Lin Li
    Qili Zhang
    Zhaoyan Zhang
    Xin Zhang
    Yunli Zhao
    Miao Yu
    Zhiguo Yu
    Asian Journal of Pharmaceutical Sciences, 2017, 12 (04) : 363 - 369
  • [36] A liquid chromatographic-mass spectrometric procedure for analysis of pentaerythrityl tetranitrate metabolites - Development, validation and application to ovine serum and human plasma samples
    Staedtler, Mariann
    Wissenbach, Daniela
    Wissenbach, Dirk K.
    Franke, Laura
    Pastuschek, Jana
    Schleussner, Ekkehard
    Allison, Beth
    Peters, Frank T.
    Groten, Tanja
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2024, 1234
  • [37] Quantitative analysis of hydrocortisone in human urine using a high-performance liquid chromatographic-tandem mass spectrometric-atmospheric-pressure chemical ionization method
    Nassar, AEF
    Varshney, N
    Getek, T
    Cheng, L
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (02) : 59 - 64
  • [38] A Validated Liquid Chromatography and Tandem Mass Spectrometric Method for Simultaneous Quantitation of Tenofovir, Emtricitabine, and Efavirenz in Human Plasma and Its Pharmacokinetic Application
    Matta, M. K.
    Pilli, N. R.
    Rao, S. J. V. L. N.
    ACTA CHROMATOGRAPHICA, 2015, 27 (01) : 27 - 39
  • [39] Validation of a fully automated high throughput liquid chromatographic/tandem mass spectrometric method for roxithromycin quantification in human plasma. Application to a bioequivalence study
    Kousoulos, Constantinos
    Tsatsou, Georgia
    Dotsikas, Yannis
    Apostolou, Constantinos
    Loukas, Yannis L.
    BIOMEDICAL CHROMATOGRAPHY, 2008, 22 (05) : 494 - 501
  • [40] Rapid and sensitive liquid chromatography-tandem mass spectrometry: Assay development, validation and application to a human pharmacokinetic study
    Song, Min
    Wang, Li
    Zhao, Hua
    Hang, Taijun
    Wen, Aidong
    Yang, Lin
    Jia, Lee
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (02): : 515 - 521