Development and validation of a sensitive liquid chromatographic-tandem mass spectrometric method for the simultaneous analysis of granisetron and 7-hydroxy granisetron in human plasma and urine samples: application in a clinical pharmacokinetic study in pregnant subject

被引:8
|
作者
Zhao, Yang [1 ]
Chen, Hui-Jun [1 ,2 ]
Caritis, Steve [3 ,4 ]
Venkataramanan, Raman [1 ,3 ,5 ,6 ,7 ]
机构
[1] Univ Pittsburgh, Sch Pharm, Dept Pharmaceut Sci, Pittsburgh, PA 15261 USA
[2] Tsinghua Univ, Sch Med, Beijing 100084, Peoples R China
[3] Magee Womens Res Inst, Pittsburgh, PA USA
[4] Magee Womens Hosp, Dept Obstet & Gynecol, Pittsburgh, PA USA
[5] Univ Pittsburgh, Sch Med, Dept Pathol, Pittsburgh, PA USA
[6] Thomas Starzl Transplantat Inst, Pittsburgh, PA USA
[7] McGovern Inst Regenerat Med, Pittsburgh, PA USA
关键词
LC-MS/MS; granisetron; 7-hydroxy granisetron; plasma; urine; NON-INFERIORITY TRIAL; DOUBLE-BLIND; INTRAVENOUS GRANISETRON; POSTOPERATIVE NAUSEA; CANCER-PATIENTS; MG; CHEMOTHERAPY; PREVENTION; FLUORESCENCE; METABOLISM;
D O I
10.1002/bmc.3530
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatography-tandem mass spectrometric method for the quantification of granisetron and its major metabolite, 7-hydroxy granisetron in human plasma and urine samples was developed and validated. Respective stable isotopically labeled granisetron and 7-hydroxy granisetron were used as internal standards (IS). Chromatography was performed using an Xselect HSS T3 analytical column with a mobile phase of 20% acetonitrile in water (containing 0.2 mM ammonium formate and 0.14% formic acid, pH 4) delivered in an isocratic mode. Tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used for quantification. The standard curves were linear in the concentration ranges of 0.5-100 ng/mL for granisetron and 0.1-100 ng/mL for 7-hydroxy granisetron in human plasma samples, and 2-2000 ng/mL for granisetron and 2-1000 ng/mL for 7-hydroxy granisetron in human urine samples, respectively. The accuracies were >85% and the precision as determined by the coefficient of variations was <10%. No significant matrix effects were observed for granisetron or 7-hydroxy granisetron in either plasma or urine samples. Granisetron was stable under various storage and experimental conditions. This validated method was successfully applied to a pharmacokinetic study after intravenous administration of 1 mg granisetron to a pregnant subject. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 50 条
  • [21] Liquid chromatographic-tandem mass spectrometric method for the plant lignan 7-hydroxymatairesinol and its potential metabolites in human plasma
    Smeds, A
    Hakala, K
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 793 (02): : 297 - 308
  • [22] Application of a sensitive liquid chromatographic/tandem mass spectrometric method to a pharmacokinetic study of allylestrenol in healthy Chinese female volunteers
    Shi, Xiaopeng
    Wu, Yin
    Hang, Taijun
    Xu, Xiaofeng
    Ding, Likun
    Tian, Yun
    Wen, Aidong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (01): : 90 - 94
  • [23] Application of a liquid chromatographic/tandem mass spectrometric method to a kinetic study of derivative glucosamine in healthy human urine
    Guan, Yue
    Tian, Yun
    Li, Yan
    Yang, Zhifu
    Jia, Yanyan
    Hang, Taijun
    Wen, Aidong
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (01) : 181 - 186
  • [24] Development and validation of a liquid chromatographic/tandeln mass spectrometric method for determination of tetracycline in human plasma: Application to bioequivalence study
    Brum Junior, Liberato
    Pugens, Ana Maria
    Pritsch, Mariely Camila
    Mantovani, Patricia Bertuol
    dos Santos, Mauricio Bedim
    Manfio, Joselia Larger
    JOURNAL OF AOAC INTERNATIONAL, 2008, 91 (04) : 731 - 738
  • [25] Development and bioanalytical validation of a liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method for the quantification of the CCR5 antagonist maraviroc in human plasma
    Emory, Joshua F.
    Seserko, Lauren A.
    Marzinke, Mark A.
    CLINICA CHIMICA ACTA, 2014, 431 : 198 - 205
  • [26] Development and validation of a specific and sensitive liquid chromatography tandem mass spectrometry method for determination of tetrodotoxin in human urine and its pharmacokinetic study
    Chen, Weizhu
    Zhang, Yiping
    Fang, Hua
    Chen, Hui
    He, Jianlin
    Yi, Ruizao
    Hong, Zhuan
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (09)
  • [27] Application of liquid chromatographic/tandem mass spectrometric method to a urinary excretion study of subutinib and active metabolite in human urine
    Ding, Li-kun
    Yang, Lin
    Gao, Xiao-hua
    Chen, Su-ning
    Jia, Na
    Li, Xue-qing
    Zhou, Lun
    Hang, Tai-jun
    Wen, Ai-dong
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (04) : 596 - 600
  • [28] Development, validation and application of an ultra high performance liquid chromatographic-tandem mass spectrometric method for the simultaneous detection and quantification of five different classes of veterinary antibiotics in swine manure
    Van den Meersche, Tina
    Van Pamel, Els
    Van Poucke, Christof
    Herman, Lieve
    Heyndrickx, Marc
    Rasschaert, Geertrui
    Daeseleire, Els
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1429 : 248 - 257
  • [29] Development and validation of liquid chromatography-mass spectrometric method for simultaneous determination of moxifloxacin and ketorolac in rat plasma: application to pharmacokinetic study
    Raju, B.
    Ramesh, M.
    Borkar, Roshan M.
    Padiya, Raju
    Banerjee, Sanjay K.
    Srinivas, R.
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (11) : 1341 - 1347
  • [30] Highly sensitive high-performance liquid chromatographic tandem mass spectrometric method for the analysis of dextromethorphan in human plasma
    Eichhold, TH
    Quijano, M
    Seibel, WL
    Cruze, CA
    Dobson, RLM
    Wehmeyer, KR
    JOURNAL OF CHROMATOGRAPHY B, 1997, 698 (1-2): : 147 - 154