Performance of electronic portal imaging devices (EPIDs) used in radiotherapy:: Image quality and dose measurements

被引:47
|
作者
Cremers, F [1 ]
Frenzel, T [1 ]
Kausch, C [1 ]
Albers, D [1 ]
Schönborn, T [1 ]
Schmidt, R [1 ]
机构
[1] Univ Hamburg Hosp, Clin Radiotherapy & Radiooncol, D-20246 Hamburg, Germany
关键词
portal imaging; image quality; amorphous silicon array; fluoroscopic portal imaging system; response; dosimetry; radiation therapy;
D O I
10.1118/1.1688212
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of our Study was to compare the image and dosimetric quality of two different imaging systems. The first one is a fluoroscopic electronic portal imaging device (first generation), while the second is based on an amorphous silicon flat-panel array (second generation). The parameters describing image quality include spatial resolution [modulation transfer function (MTF)], noise [noise power spectrum (NPS)], and signal-to-noise transfer [detective quantum efficiency (DQE)]. The dosimetric measurements were compared with ionization chamber as well as with film measurements. The response of the flat-panel imager and the fluoroscopic-optical device was determined performing a two-step Monte Carlo simulation. All measurements were performed in a 6 MV linear accelerator photon beam. The resolution (MTF) of the fluoroscopic device (f(1/2) = 0.3 mm(-1)) is larger than of the amorphous silicon based system (f(1/2) = 0.21 mm(-1)), which is due to the missing backscattered photons and the smaller pixel size. The noise measurements (NPS) show the correlation of neighboring pixels of the amorphous silicon electronic portal imaging device, whereas the NPS of the fluoroscopic system is frequency independent. At zero spatial frequency the DQE of the flat-panel imager has a value of 0.008 (0.8%). Due to the minor frequency dependency this device may be almost x-ray quantum limited. Monte Carlo simulations verified these characteristics. For the fluoroscopic imaging system the DQE at low frequencies is about 0.0008 (0.08%) and degrades with higher frequencies. Dose measurements with the flat-panel imager revealed that images can only be directly converted to portal dose images, if scatter can be neglected. Thus objects distant to the detector (e.g., inhomogeneous dose distribution generated by a modificator) can be verified dosimetrically, while objects close to a detector (e.g., a patient) cannot be verified directly and must be scatter corrected prior to verification. This is justified by the response of the flat-panel imaging device revealing a strong dependency at low energies. (C) 2004 American Association of PhYsicists in Medicine.
引用
收藏
页码:985 / 996
页数:12
相关论文
共 50 条
  • [21] A phantom based evaluation of the clinical imaging performance of electronic portal imaging devices
    Tzomakas, Marios K.
    Peppa, Vasiliki
    Alexiou, Antigoni
    Karakatsanis, Georgios
    Episkopakis, Anastasios
    Michail, Christos
    Valais, Ioannis
    Fountos, George
    Kalyvas, Nektarios
    Kandarakis, Ioannis S.
    HELIYON, 2023, 9 (10)
  • [22] Image quality improvements of electronic portal imaging devices by multi-level gain calibration and temperature correction
    Huber, S.
    Mooslechner, M.
    Mitterlechner, B.
    Weichenberger, H.
    Serpa, M.
    Sedlmayer, F.
    Deutschmann, H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (18): : 6429 - 6446
  • [23] ROLE OF ELECTRONIC PORTAL IMAGING IN HIGH-DOSE HIGH-PRECISION RADIOTHERAPY
    VANHERK, M
    GILHUIJS, K
    WILLIAMS, P
    CINQUIN, P
    CIONINI, L
    SWINDELL, W
    RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 269 - 270
  • [24] Importance of daily electronic portal imaging in radiotherapy
    Bell, L. J.
    Shakespeare, T. P.
    Willis, A.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2008, 52 (04) : 414 - 418
  • [25] The use of an electronic portal imaging system to measure portal dose and portal dose profiles
    Parsaei, H
    El-Khatib, E
    Rajapakshe, R
    MEDICAL PHYSICS, 1998, 25 (10) : 1903 - 1909
  • [26] Portal dose measurements with a video-based electronic portal imaging device using a deconvolution algorithm
    Pasma, KL
    Kroonwijk, M
    Visser, AG
    Heijmen, BJM
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 282 - 284
  • [27] Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device
    McCurdy, BMC
    Luchka, K
    Pistorius, S
    MEDICAL PHYSICS, 2001, 28 (06) : 911 - 924
  • [28] Techniques for commissioning electronic portal imaging devices
    Shalev, S
    Luchka, K
    Rajapakshe, R
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 272 - 275
  • [29] Silicon Array Dosimeter in Situ with Electronic Portal Image Device for Simultaneous Transit Dose and Image Verification in Radiotherapy
    Deshpande, S.
    Alhujaili, S.
    Vial, P.
    Holloway, L.
    Petasecca, M.
    Rozenfeld, A.
    Metcalfe, P.
    MEDICAL PHYSICS, 2016, 43 (06) : 3316 - 3316
  • [30] Electronic Portal Image Processing for High Precision Radiotherapy
    Hakim, Aayesha
    Talele, K. T.
    Harsh, Rajesh
    Verma, Dharmesh
    2015 INTERNATIONAL CONFERENCE ON COMPUTATION OF POWER, ENERGY, INFORMATION AND COMMUNICATION (ICCPEIC), 2015, : 7 - 11