Dual-Mode Integrated Circuit for Imaging and HIFU With 2-D CMUT Arrays

被引:10
|
作者
Jang, Ji Hoon [1 ]
Rasmussen, Morten Fischer [1 ]
Bhuyan, Anshuman [1 ]
Yoon, Hyo-Seon [1 ]
Moini, Azadeh [1 ]
Chang, Chienliu [1 ]
Watkins, Ronald D. [2 ]
Choe, Jung Woo [1 ]
Nikoozadeh, Amin [1 ]
Stephens, Douglas [3 ]
Oralkan, Oemer [4 ]
Pauly, Kim Butts [2 ]
Khuri-Yakub, Butrus [1 ]
机构
[1] Stanford Univ, Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Radiol, Stanford, CA 94305 USA
[3] Univ Calif Davis, Biomed Engn, Davis, CA 95616 USA
[4] N Carolina State Univ, Elect & Comp Engn, Raleigh, NC 27695 USA
关键词
ULTRASOUND;
D O I
10.1109/ULTSYM.2015.0166
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Successful high intensity focused ultrasound (HIFU) operation requires a reliable guidance and monitoring method such as magnetic resonance imaging (MRI) or ultrasound imaging. However, both widely used modalities are typically separate from the HIFU system, which makes co-registration of HIFU with cross-sectional imaging difficult. In this paper, we present a dual-mode integrated circuit (IC) that can perform both ultrasound imaging and HIFU with a single 2D capacitive micromachined ultrasonic transducer (CMUT) array, combining these two systems for ease of use. The dual-mode IC consists of pulsers, transmit beamforming circuitry, and low-noise amplifiers for imaging mode and switches for HIFU mode. By turning this switching network on and off, the system can alternately operate the imaging mode and HIFU mode on demand. The dual-mode IC was designed and fabricated in the 0.18-mu m HV 4LM process provided by Maxim Inc. We fabricated a 32. 32-element CMUT array that has a center frequency of 5 MHz using a sacrificial release process and flip-chip bonded this CMUT array to the IC. With the back-end system, real-time volumetric imaging on the wire phantom and HIFU ablation on ex-vivo tissue were performed respectively.
引用
收藏
页数:4
相关论文
共 50 条
  • [11] Performance Assessment of Ultra-Wideband and Dual-Mode 1D CMUT Arrays for Acoustic Angiography
    Belekov, Ermek
    Bautista, Kathlyne J.
    Annayev, Muhammetgeldi
    Adelegan, Oluwafemi J.
    Biliroglu, Ali O.
    Kierski, Thomas M.
    Sanders, Jean L.
    Kemal, Remzi E.
    Sennik, Erdem
    Yamaner, Feysel Y.
    Dayton, Paul A.
    Oralkan, Omer
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [12] Design and Fabrication of 1D CMUT Arrays for Dual-Mode Acoustic Angiography Applications - Preliminary Results
    Annayev, Muhammetgeldi
    Adelegan, Oluwafemi J.
    Yamaner, F. Yalcin
    Dayton, Paul A.
    Oralkan, Omer
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [13] A 1-MHz 2-D CMUT Array for HIFU Thermal Ablation
    Yoon, Hyo-Seon
    Vaithilingam, Srikant
    Park, Kwan Kyu
    Nikoozadeh, Amin
    Firouzi, Kamyar
    Choe, Jung Woo
    Watkins, Ronald D.
    Oguz, Huseyin Kagan
    Kupnik, Mario
    Pauly, Kim Butts
    Khuri-Yakub, Pierre
    PROCEEDINGS FROM THE 14TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2017, 1821
  • [14] An Integrated Circuit With Transmit Beamforming Flip-Chip Bonded to a 2-D CMUT Array for 3-D Ultrasound Imaging
    Wygant, Ira O.
    Jamal, Nafis S.
    Lee, Hyunjoo J.
    Nikoozadeh, Amin
    Oralkan, Oemer
    Karaman, Mustafa
    Khuri-Yakub, Butrus T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (10) : 2145 - 2156
  • [15] Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays
    Çiçek, I
    Bozkurt, A
    Karaman, M
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (12) : 2235 - 2241
  • [16] Dual-mode ultrasound phased arrays for imaging and therapy
    Yao, H
    Ebbini, ES
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, 2004, : 25 - 28
  • [17] Hybrid Volume Beamforming for 3-D Ultrasound Imaging using 2-D CMUT Arrays
    Kim, Bae-Hyung
    Song, Tai-Kyong
    Yoo, Yangmo
    Chang, Jin Ho
    Lee, Seunghun
    Kim, Youngil
    Cho, Kyungil
    Song, Jongkeun
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 2246 - 2249
  • [18] A Dual-Mode Readout Circuit for SPAD Imaging Applications
    Huang, Hsi-Hao
    Huang, Tzu-Yun
    Liu, Chun-Hsien
    Lin, Sheng-Di
    Lee, Chen-Yi
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2024, 71 (04) : 1879 - 1883
  • [19] VOLUMETRIC ELASTICITY IMAGING WITH A 2-D CMUT ARRAY
    Fisher, Ted G.
    Hall, Timothy J.
    Panda, Satchi
    Richards, Michael S.
    Barbone, Paul E.
    Jiang, Jingfeng
    Resnick, Jeff
    Barnes, Steve
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (06): : 978 - 990
  • [20] Top Orthogonal to Bottom Electrode (TOBE) 2-D CMUT Arrays for 3-D Photoacoustic Imaging
    Chee, Ryan K. W.
    Sampaleanu, Alexander
    Rishi, Deepak
    Zemp, Roger J.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (08) : 1393 - 1395