Mortality in patients supported by intra-aortic balloon pump in the course of cardiac surgery was related to perioperative myocardial infarction

被引:11
|
作者
Aksnes, J
Abdelnoor, M
Platou, ES
Fjeld, NB
机构
[1] Surgical Department A, Rikshospitalet
[2] Clinical Research Unit, Ullevål Hospital, University of Oslo
[3] Medical Clinic, Ullevål Hospital, University of Oslo
[4] Department of Thoracic Surgery, Ullevål Hospital, University of Oslo
关键词
intra-aortic balloon pump (IABP); perioperative myocardial infarction (PMI); cardiac surgery;
D O I
10.1016/S1010-7940(96)80106-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To search for predictors of mortality for patients in need of intra-aortic balloon pump (LABP) support in the course of cardiac surgery. Methods. A retrospective study of possible pre- and perioperative risk factors in 110 patients with mean age of 62 years (35-79). The IABP was inserted preoperatively in 19 (17%) and preoperatively in 91 (83%). Results. Well known risk factors as advanced age (63.2/61.0; P = 0.25), NYHA functional class (OR = 1.59; 95% CI 0.23 to 13.31), female sex (OR = 2.40; 95% CI 0.81 to 6.73), emergency surgery (OR = 0.63; 95% CI 0.21 to 1.80), low left ventricular ejection fraction (62.9/60.7; P = 0.53), or elevated end diastolic pressure (19.4/21.0; P = 0.48), were not prognostic of death, Perioperative insertion of the balloon pump (OR = 3.83; 95% CI 1.07 to 14.95), perioperative myocardial infarction (OR = 23.3; 95% CI 7.62 to 81.8), low cardiac output (OR = 7.53; 95% CI 2.43 to 24.11), and renal failure (OR = 20.00; 95% CI 3.63 to 145), were strong predictors of death. Conclusions. Outcome seemed to be determined by perioperative events rather than preoperative risk factors. This could possibly explain the favourable mortality rates seen in patients on IABP support prior to surgery compared to patients who had IABP installed perioperatively.
引用
收藏
页码:408 / 411
页数:8
相关论文
共 50 条
  • [41] Intra-aortic balloon pump therapy for acute myocardial infarction: Trial sequential analysis
    Phan, Kevin
    Phan, Steven
    Khuong, Jacqueline Nguyen
    Yan, Tristan D.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 202 : 520 - 521
  • [42] Intra-aortic balloon pump counterpulsation (IABP) for myocardial infarction complicated by cardiogenic shock
    Unverzagt, Susanne
    Machemer, Maria-Theresia
    Solms, Alexander
    Thiele, Holger
    Burkhoff, Daniel
    Seyfarth, Melchior
    de Waha, Antoinette
    Ohman, E. Magnus
    Buerke, Michael
    Haerting, Johannes
    Werdan, Karl
    Prondzinsky, Roland
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2011, (07):
  • [43] Intra-aortic Balloon Pump Therapy for Acute Myocardial Infarction AMeta-analysis
    Ahmad, Yousif
    Sen, Sayan
    Shun-Shin, Matthew J.
    Ouyang, Jing
    Finegold, Judith A.
    Al-Lamee, Rasha K.
    Davies, Justin E. R.
    Cole, Graham D.
    Francis, Darrel P.
    JAMA INTERNAL MEDICINE, 2015, 175 (06) : 931 - 939
  • [44] Evaluation of continuous monitoring of stroke volume and cardiac output in patients supported by an intra-aortic balloon pump
    Podbregar, M.
    Kosir, M.
    Stajer, D.
    Zdovc, J.
    Plaskan, S.
    MINERVA ANESTESIOLOGICA, 2013, 79 (07) : 762 - 770
  • [45] High Risk Intervention in Non-ST-segment Elevation Myocardial Infarction Supported by Intra-aortic Balloon Pump
    Lee, Jun-Won
    Lee, Seung-Hwan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (16) : S220 - S221
  • [46] Features and markers of mortality of hospital patients that use intra-aortic balloon pump
    AD Porto
    JV Morgado
    MI Bitencourt
    RV Gomes
    LA Campos
    MA Fernandes
    PM Nogueira
    SA Silva
    HCV Rey
    HF Dohmann
    Critical Care, 5 (Suppl 3):
  • [47] Influence of cardiogenic shock with or without the use of intra-aortic balloon pump on mortality in patients with ST-segment elevation myocardial infarction
    Jensen, Jesper Khedri
    Thayssen, Per
    Antonsen, Lisbeth
    Hougaard, Mikkel
    Junker, Anders
    Pedersen, Knud Erik
    Jensen, Lisette Okkels
    IJC HEART & VASCULATURE, 2015, 6 : 19 - 24
  • [48] Myocardial perfusion improvement by preoperative intra-aortic balloon pump
    Locorotondo, Gabriella
    D'Amario, Domenico
    Massetti, Massimo
    REVISTA ESPANOLA DE CARDIOLOGIA, 2021, 74 (04): : 346 - 346
  • [49] CLINICAL AND HEMODYNAMIC CRITERIA FOR USE OF INTRA-AORTIC BALLOON PUMP IN PATIENTS REQUIRING CARDIAC-SURGERY
    BOLOOKI, H
    WILLIAMS, W
    THURER, RJ
    VARGAS, A
    KAISER, GA
    MACK, F
    GHAHRAMANI, AR
    FRIED, A
    NOVAK, S
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1976, 72 (05): : 756 - 768
  • [50] PLACEMENT OF INTRA-AORTIC BALLOON PUMP ALLOWS DEFINITIVE BILIARY SURGERY IN PATIENTS WITH SEVERE CARDIAC DISEASE
    GEORGEN, RF
    DIETRICK, JA
    PIFARRE, R
    SCANLON, PJ
    PRINZ, RA
    SURGERY, 1989, 106 (04) : 808 - 814