Mortality in patients supported by intra-aortic balloon pump in the course of cardiac surgery was related to perioperative myocardial infarction

被引:11
|
作者
Aksnes, J
Abdelnoor, M
Platou, ES
Fjeld, NB
机构
[1] Surgical Department A, Rikshospitalet
[2] Clinical Research Unit, Ullevål Hospital, University of Oslo
[3] Medical Clinic, Ullevål Hospital, University of Oslo
[4] Department of Thoracic Surgery, Ullevål Hospital, University of Oslo
关键词
intra-aortic balloon pump (IABP); perioperative myocardial infarction (PMI); cardiac surgery;
D O I
10.1016/S1010-7940(96)80106-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. To search for predictors of mortality for patients in need of intra-aortic balloon pump (LABP) support in the course of cardiac surgery. Methods. A retrospective study of possible pre- and perioperative risk factors in 110 patients with mean age of 62 years (35-79). The IABP was inserted preoperatively in 19 (17%) and preoperatively in 91 (83%). Results. Well known risk factors as advanced age (63.2/61.0; P = 0.25), NYHA functional class (OR = 1.59; 95% CI 0.23 to 13.31), female sex (OR = 2.40; 95% CI 0.81 to 6.73), emergency surgery (OR = 0.63; 95% CI 0.21 to 1.80), low left ventricular ejection fraction (62.9/60.7; P = 0.53), or elevated end diastolic pressure (19.4/21.0; P = 0.48), were not prognostic of death, Perioperative insertion of the balloon pump (OR = 3.83; 95% CI 1.07 to 14.95), perioperative myocardial infarction (OR = 23.3; 95% CI 7.62 to 81.8), low cardiac output (OR = 7.53; 95% CI 2.43 to 24.11), and renal failure (OR = 20.00; 95% CI 3.63 to 145), were strong predictors of death. Conclusions. Outcome seemed to be determined by perioperative events rather than preoperative risk factors. This could possibly explain the favourable mortality rates seen in patients on IABP support prior to surgery compared to patients who had IABP installed perioperatively.
引用
收藏
页码:408 / 411
页数:8
相关论文
共 50 条
  • [21] Encouraging survival rates in patients with acute myocardial infarction treated with an intra-aortic balloon pump
    Valk, S. D. A.
    Cheng, J. M.
    den Uil, C. A.
    Lagrand, W. K.
    van der Ent, M.
    van de Sande, M.
    van Domburg, R. T.
    Simoons, M. L.
    NETHERLANDS HEART JOURNAL, 2011, 19 (03) : 112 - 118
  • [22] Intra-Aortic Balloon Pump Support in Patients with Acute Myocardial Infarction with Ventricular Septal Rupture
    Luo, Xiao-Liang
    Xu, Haobo
    Guo, Chao
    Li, Jia
    Yuan, Jiansong
    Ma, Yue
    Zhang, Jun
    Qiao, Shubin
    CARDIOVASCULAR INNOVATIONS AND APPLICATIONS, 2024, 9 (01) : 1 - 10
  • [23] The use of an intra-aortic balloon pump in patients with cardiogenic shock secondary to acute myocardial infarction
    Qutub, Mohammed A.
    CARDIOTHORACIC SURGEON, 2025, 33 (01):
  • [24] Cochrane Corner: Intra-aortic balloon pump in patients with cardiogenic shock following myocardial infarction
    Caldeira, Daniel
    Pereira, Helder
    Costa, Joao
    Vaz-Carneiro, Antonio
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2016, 35 (04) : 229 - 231
  • [25] Predictors of morbidity and mortality in patients undergoing intra-aortic counterpulsation balloon in cardiac surgery
    Elahmadi, Brahim
    Motiaa, Youssef
    Elghadbane Hatim, Abdedaim
    Atmani, Noureddine
    Moutakillah, Younes
    Amal Wahid, Fouad
    Elbekkali, Youssef
    Ait Houssa, Mahdi
    Razine, Rachid
    Boulahya, Abdelatif
    Drissi, Mohammed
    PAN AFRICAN MEDICAL JOURNAL, 2015, 21
  • [26] Course of patients with cardiogenic shock supported with intra-aortic balloon couterpulsation
    Issa, Victor
    Ayub, Silvia
    Lage, Silvia
    Bocchi, Edimar
    ACTA CARDIOLOGICA, 2019, 74 : 22 - 22
  • [27] Role of intra-aortic balloon pump in myocardial contusion
    Vu, T.
    Stahl, K. D.
    Asensio, J. A.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2011, 93 (06) : 490 - 491
  • [28] USE OF INTRA-AORTIC BALLOON PUMP IN CARDIAC SURGERY: ANALYSIS OF THE CARDIAC SURGERY REGISTER ARIAM
    Trujillo-Garcia, E.
    Munoz-Bono, J.
    Gomez-Gallego, G.
    Curiel-Balsera, E.
    Mora-Ordonez, J.
    Martinez-Gonzalez, M. C.
    INTENSIVE CARE MEDICINE, 2014, 40 : S115 - S115
  • [29] Levosimendan Versus an Intra-aortic Balloon Pump in Adult Cardiac Surgery Patients With Low Cardiac Output
    Elahi, Maqsood M.
    Lam, Jimmy
    Asopa, Sanjay
    Matata, Bashir M.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2011, 25 (06) : 1154 - 1162
  • [30] Perioperative heart failure in coronary surgery and timing of intra-aortic balloon pump insertion
    Ranucci, M.
    Ballotta, A.
    Castelvecchio, S.
    De Vincentiis, C.
    Biondi, A.
    Parisi, A.
    Menicanti, L.
    Frigiola, A.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (07) : 878 - 884