Monte Carlo studies of the exit photon spectra and dose to a metal/phosphor portal imaging screen

被引:26
|
作者
Yeboah, C [1 ]
Pistorius, S
机构
[1] Tom Baker Canc Ctr, Dept Med Phys, Calgary, AB T2N 4NA, Canada
[2] Univ Calgary, Dept Phys & Astron, Calgary, AB T2N 2N4, Canada
[3] Canc Care Manitoba, Winnipeg, MB R3E 0V9, Canada
[4] Univ Manitoba, Dept Phys & Astron, Winnipeg, MB R3T 2N2, Canada
[5] Univ Manitoba, Dept Radiol, Winnipeg, MB R3T 0W3, Canada
关键词
exit dose; portal imaging; energy spectrum; mean energy; effective energy;
D O I
10.1118/1.598835
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The energy spectra and the dose to a Cu plate/Gd2O2S phosphor portal imaging detector were investigated for monoenergetic incident beams of photons (1.25, 2, and 5 MeV). The Monte Carlo method was used to characterize the influence of the patient/detector geometry, detector material and design, and incident beam energy on the spectral distribution and the dose, at the imaging detector plane. of a photon beam scattered from a water phantom. The results show that radiation equilibrium is lost in the air gap and that, for the geometries studied, this effect led to a reduction in the exit dose of up to 40%. The finding that the effects of the air gap and held size are roughly complementary has led to the hypothesis that an equivalent field size concept may be used to account for intensity and spectral changes arising from air gap variations. The copper plate preferentially attenuates the low-energy scattered photons incident on it, while producing additional annihilation, bremsstrahlung, and scattered photons. As a result, the scatter spectra at the copper surface entrance of the detector differs significantly from that at the Cu/phosphor interface. In addition, the mean scattered photon energy at the interface was observed to be roughly 0.4 MeV higher than the corresponding effective energy for 2 MeV incident beams. A comparison of the dose to various detector materials showed that exit dosimetry errors of up to 24% will occur if it is assumed that the Cu plate/Gd2O2S phosphor detector is water equivalent. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)01002-6].
引用
收藏
页码:330 / 339
页数:10
相关论文
共 50 条
  • [21] Dose reduction in small animal imaging using a modified phosphor screen
    Osborne, Dustin
    Stuckey, Alan
    Kennel, Steve
    Richey, Tina
    Pryer, Lindy
    Yan, Shikui
    Wall, Jonathan
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [22] A virtual photon energy fluence model for Monte Carlo dose calculation
    Fippel, M
    Haryanto, F
    Dohm, O
    Nüsslin, F
    Kriesen, S
    MEDICAL PHYSICS, 2003, 30 (03) : 301 - 311
  • [23] A multiple source model for Monte Carlo photon dose calculations in radiotherapy
    Fix, MK
    Stampanoni, M
    Keller, H
    Born, EJ
    Mini, R
    Ruegsegger, P
    PATRAS MEDICAL PHYSICS 99, 1999, : 89 - 93
  • [24] Comparison of dose calculation algorithms with Monte Carlo methods for photon arcs
    Chow, JCL
    Wong, E
    Chen, JZ
    Van Dyk, J
    MEDICAL PHYSICS, 2003, 30 (10) : 2686 - 2694
  • [25] Clinical Implementation and Application of Monte Carlo in Photon and Electron Dose Calculations
    DeMarco, J.
    Cygler, J.
    MEDICAL PHYSICS, 2010, 37 (06) : 3336 - 3337
  • [26] Super Monte Carlo: A photon/electron dose calculation algorithm for radiotherapy
    Keall, PJ
    Hoban, PW
    West, MP
    RADIATION PHYSICS AND CHEMISTRY, 1998, 53 (03): : 275 - 281
  • [27] Monte Carlo model for IOERT dose distribution studies
    Esposito, A.
    Sakellaris, T.
    Limede, P.
    Costa, F.
    Cunha, L. T.
    Dias, A. G.
    Lencart, J.
    Sarmento, S.
    Rosa, C. C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S416 - S416
  • [28] A Monte Carlo study of the impact of phosphor optical properties on EPID imaging performance
    Shi, Mengying
    Myronakis, Marios
    Hu, Yue-Houng
    Morf, Daniel
    Rottmann, Joerg
    Berbeco, Ross
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (16):
  • [29] Influence of photon energy spectra from brachytherapy sources on Monte Carlo simulations of kerma and dose rates in water and air
    Rivard, Mark J.
    Granero, Domingo
    Perez-Calatayud, Jose
    Ballester, Facundo
    MEDICAL PHYSICS, 2010, 37 (02) : 869 - 876
  • [30] Monte Carlo investigations on portal dose measurements with an A-Si:H EPID
    Manser, P
    Fix, MK
    Figini, S
    Barengo, R
    Born, EJ
    Mini, R
    Rüegsegger, P
    MEDICAL PHYSICS, 2002, 29 (06) : 1316 - 1316