A Selective and Sensitive Gas Chromatography-Tandem Mass Spectrometry Method for Quantitation of Synthetic Musks in Human Serum

被引:6
|
作者
Katuri, Guru Prasad [1 ]
Fan, Xinghua [1 ]
Siddique, Shabana [1 ]
Kubwabo, Cariton [1 ]
Kosarac, Ivana [2 ]
Harris, Shelley A. [3 ]
Foster, Warren G. [4 ]
机构
[1] Hlth Canada, Environm Hlth Sci & Res Bur, Ottawa, ON, Canada
[2] Hlth Canada, Tobacco Control Directorate, Off Res & Surveillance, Ottawa, ON, Canada
[3] Univ Toronto, Dalla Lana Sch Publ Hlth, Toronto, ON, Canada
[4] McMaster Univ, Dept Obstet & Gynecol, Hamilton, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
HUMAN BREAST-MILK; UMBILICAL-CORD BLOOD; POLYCYCLIC MUSKS; FRAGRANCES; SAMPLES; XYLENE; WATER; FISH; MICROEXTRACTION; EXTRACTION;
D O I
10.1093/jaoacint/qsaa051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Synthetic musk compounds are widely used as fragrances in many consumer products; however, information co on human exposure and health effects is limited. Also, analytical methods for their quantification in biological matrices are limited. Objective: In this study, an integrated method was developed and validated for the analysis of selected synthetic musk compounds in human serum. Method: The method is based on liquid-liquid extraction (LLE), sample clean-up by solid-phase extraction (SPE), and separation and detection by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). Results: The method demonstrated good recoveries (86-105%) and high sensitivity, with low method detection limits (MDLs) ranging from 0.04 to 0.17 mu g/L. The method was applied to the analysis of 10 synthetic musk compounds in 40 serum samples collected from Canadian women aged 20-44 years (20 individual samples collected in 2014 and 20 pooled samples collected in 2006). The most commonly detected compound was Galaxolide (HHCB), with median concentrations of 0.59 mu g/L in samples collected in 2006, and 0.34 mu g/L for samples collected in 2014. Musk ketone (MK) was not detected in any of the samples collected in 2006, but was detected in 60% of the samples collected in 2014 with a median concentration of 0.29 mu g/L. Tonalide (AHTN) was detected in only one sample above its MDL (0.12 mu g/L). Conclusions: This is the first study in Canada to report levels of synthetic musks in human. The data generated from this 3 study has been used in risk screening assessment by Environment and Climate Change Canada and Health Canada.
引用
收藏
页码:1461 / 1468
页数:8
相关论文
共 50 条
  • [41] Analysis of endosulfan and its metabolites in human serum using gas chromatography-tandem mass spectrometry
    Arrebola, FJ
    Vidal, JLM
    Fernández-Gutiérrez, A
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2001, 39 (05) : 177 - 182
  • [42] Determination of Lamotrigine in Human Serum By Liquid Chromatography-Tandem Mass Spectrometry
    Lee, W.
    Yoon, S.
    Park, Y.
    Suh, B.
    Kwon, O. H.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A261 - A261
  • [43] Measurement of tamsulosin in human serum by liquid chromatography-tandem mass spectrometry
    Upreti, Rita
    Homer, Natalie Z. M.
    Naredo, Gregorio
    Cobice, Diego F.
    Hughes, Katherine A.
    Stewart, Laurence H.
    Walker, Brian R.
    Andrew, Ruth
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 930 : 121 - 128
  • [44] Determination of Tirofiban in human serum by liquid chromatography-tandem mass spectrometry
    Oertel, R
    Köhler, A
    Koster, A
    Kirch, W
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (01): : 181 - 185
  • [45] Sensitive determination of pethidine in body fluids by gas chromatography-tandem mass spectrometry
    Ishii, A
    Tanaka, M
    Kurihara, R
    Watanabe-Suzuki, K
    Kumazawa, T
    Seno, H
    Suzuki, O
    Katsumata, Y
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (01): : 117 - 121
  • [46] Sensitive and reproducible liquid chromatography-tandem mass spectrometry method for quantification of sibutramine in human plasma
    Nirogi R.V.S.
    Kandikere V.
    Shukla M.
    Mudigonda K.
    Maurya S.
    Forensic Toxicology, 2007, 25 (1) : 30 - 36
  • [47] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the estimation of nicorandil in human plasma
    Bhatt, Jignesh
    Jangid, Arvind
    Shah, Bhavin
    Shetty, Raghavendra
    Kambli, Sandeep
    Subbaiah, Gunta
    Singh, Sadhana
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (09) : 864 - 869
  • [48] Sensitive method for the quantitative determination of bromocriptine in human plasma by liquid chromatography-tandem mass spectrometry
    Salvador, A
    Dubreuil, D
    Denouel, J
    Millerioux, L
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (02): : 237 - 242
  • [49] A sensitive liquid chromatography-tandem mass spectrometry method for the quantification of mometasone furoate in human plasma
    Sahasranaman, S
    Tang, YF
    Biniasz, D
    Hochhaus, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (01): : 175 - 179
  • [50] Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of meloxicam in human plasma
    Wiesner, JL
    de Jager, AD
    Sutherland, FCW
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    Els, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (01): : 115 - 121