A Selective and Sensitive Gas Chromatography-Tandem Mass Spectrometry Method for Quantitation of Synthetic Musks in Human Serum

被引:6
|
作者
Katuri, Guru Prasad [1 ]
Fan, Xinghua [1 ]
Siddique, Shabana [1 ]
Kubwabo, Cariton [1 ]
Kosarac, Ivana [2 ]
Harris, Shelley A. [3 ]
Foster, Warren G. [4 ]
机构
[1] Hlth Canada, Environm Hlth Sci & Res Bur, Ottawa, ON, Canada
[2] Hlth Canada, Tobacco Control Directorate, Off Res & Surveillance, Ottawa, ON, Canada
[3] Univ Toronto, Dalla Lana Sch Publ Hlth, Toronto, ON, Canada
[4] McMaster Univ, Dept Obstet & Gynecol, Hamilton, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
HUMAN BREAST-MILK; UMBILICAL-CORD BLOOD; POLYCYCLIC MUSKS; FRAGRANCES; SAMPLES; XYLENE; WATER; FISH; MICROEXTRACTION; EXTRACTION;
D O I
10.1093/jaoacint/qsaa051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Synthetic musk compounds are widely used as fragrances in many consumer products; however, information co on human exposure and health effects is limited. Also, analytical methods for their quantification in biological matrices are limited. Objective: In this study, an integrated method was developed and validated for the analysis of selected synthetic musk compounds in human serum. Method: The method is based on liquid-liquid extraction (LLE), sample clean-up by solid-phase extraction (SPE), and separation and detection by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). Results: The method demonstrated good recoveries (86-105%) and high sensitivity, with low method detection limits (MDLs) ranging from 0.04 to 0.17 mu g/L. The method was applied to the analysis of 10 synthetic musk compounds in 40 serum samples collected from Canadian women aged 20-44 years (20 individual samples collected in 2014 and 20 pooled samples collected in 2006). The most commonly detected compound was Galaxolide (HHCB), with median concentrations of 0.59 mu g/L in samples collected in 2006, and 0.34 mu g/L for samples collected in 2014. Musk ketone (MK) was not detected in any of the samples collected in 2006, but was detected in 60% of the samples collected in 2014 with a median concentration of 0.29 mu g/L. Tonalide (AHTN) was detected in only one sample above its MDL (0.12 mu g/L). Conclusions: This is the first study in Canada to report levels of synthetic musks in human. The data generated from this 3 study has been used in risk screening assessment by Environment and Climate Change Canada and Health Canada.
引用
收藏
页码:1461 / 1468
页数:8
相关论文
共 50 条
  • [1] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of domperidone in human plasma
    Smit, MJ
    Sutherland, FCW
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    Els, J
    JOURNAL OF CHROMATOGRAPHY A, 2002, 949 (1-2) : 65 - 70
  • [2] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of colchicine in human plasma
    Jiang, Yao
    Wang, Jiang
    Wang, Yingwu
    Li, Hao
    Fawcett, J. Paul
    Gu, Jingkai
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 850 (1-2): : 564 - 568
  • [3] Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of levodropropizine in human plasma
    Tang, YB
    Zhao, LM
    Wang, YW
    Fawcett, JP
    Gu, JK
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (01): : 185 - 189
  • [4] Mucopolysaccharides quantitation in serum by liquid chromatography-tandem mass spectrometry
    Raymond, Kimiyo
    Lacey, Jean M.
    Dimitar, Gavrilov
    Matern, Dietrich
    Oglesbee, Devin
    Rinaldo, Piero
    Tortorelli, Silvia
    MOLECULAR GENETICS AND METABOLISM, 2018, 123 (02) : S123 - S123
  • [5] A Selective Gas Chromatography-Tandem Mass Spectrometry Method for Quantitation of Ethylene and Diethylene Glycol in Paediatric Syrups
    Altamimy, Monerah A.
    Alshehri, Yahya M.
    Aldawsari, Fahad S.
    Altalyan, Norah H.
    AlShmmari, Sultan K.
    Alzaid, Shaikah F.
    Al-Qahtani, Naif A.
    Alsagoor, Turki M.
    Al Shahrani, Mobarak S.
    HELIYON, 2024, 10 (07)
  • [6] Sensitive and selective gas chromatography-tandem mass spectrometry method for the detection of nitrobenzene in tobacco smoke
    Chapman, Gala M.
    Bravo, Roberto
    Stanelle, Rayman D.
    Watson, Clifford H.
    Valentin-Blasini, Liza
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1565 : 124 - 129
  • [7] Determination of nimodipine in human plasma by a sensitive and selective liquid chromatography-tandem mass spectrometry method
    Qiu, F
    Chen, XY
    Li, XY
    Zhong, DF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02): : 291 - 297
  • [8] Selective and sensitive liquid chromatography-tandem mass spectrometry method for the determination of levonorgestrel in human plasma
    Theron, HB
    Coetzee, C
    Sutherland, FCW
    Wiesner, JL
    Swart, KJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 813 (1-2): : 331 - 336
  • [9] Sensitive and selective liquid chromatography-tandem mass spectrometry method for the quantification of azithromycin in human plasma
    Nirogi, RVS
    Kandikere, VN
    Shukla, M
    Mudigonda, K
    Maurya, S
    Boosi, R
    Yerramilli, A
    ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) : 1 - 8
  • [10] Sensitive and selective liquid chromatography-tandem mass spectrometry method for the quantification of aniracetam in human plasma
    Zhang, Jingjing
    Liang, Jidbi
    Tian, Yuan
    Zhang, Zunjian
    Chen, Yun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 858 (1-2): : 129 - 134