Selective and sensitive liquid chromatography-tandem mass spectrometry method for the determination of levonorgestrel in human plasma

被引:30
|
作者
Theron, HB [1 ]
Coetzee, C [1 ]
Sutherland, FCW [1 ]
Wiesner, JL [1 ]
Swart, KJ [1 ]
机构
[1] PAREXEL, Clin Res Org, FARMOVS, ZA-9324 Brandhof, South Africa
关键词
levonorgestrel; 17-alpha-methyltestosterone; liquid-liquid extraction; plasma; liquid chromatography; mass spectrometry; atmospheric pressure photospray ionisation (APPI);
D O I
10.1016/j.jchromb.2004.10.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A selective, sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of levonorgestrel in plasma was developed. An Applied Biosystems API 3000 triple quadrupole mass spectrometer set to multiple reaction monitoring (MRM) mode, using atmospheric pressure photospray ionisation (APPI) in the positive mode. Using 17-alpha-methyltestosterone as internal standard (IS), liquid-liquid extraction was followed by reversed phase liquid chromatography using a phenyl-hexyl column and tandem mass spectrometric detection. The mean recovery for levonorgestrel and 17-alpha-methyltestosterone was 99.5 and 62.9%, respectively. The method was validated from 0.265 to 130 ng levonorgestrel/ml plasma with the lower limit of quantification (LLOQ) set at 0.265 ng/ml. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometric (MS/MS) detection, allowing for a rapid (extraction and chromatography) and selective method for the determination of levonorgestrel in human plasma. The assay method was used in a pharmacokinetic study to quantify levonorgestrel in human plasma samples generated after administrating a single oral dose of 1.5 mg levonorgestrel to healthy female volunteers for up to five half lives. The total chromatographic runtime of this method was 5.0 min per sample, allowing for analysis of a large number of samples per batch. (C) 2004 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:331 / 336
页数:6
相关论文
共 50 条
  • [1] Determination of nimodipine in human plasma by a sensitive and selective liquid chromatography-tandem mass spectrometry method
    Qiu, F
    Chen, XY
    Li, XY
    Zhong, DF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02): : 291 - 297
  • [2] Selective, sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of alfuzosin in human plasma
    Wiesner, JL
    Sutherland, FCW
    van Essen, GH
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (02): : 361 - 368
  • [3] Sensitive liquid chromatography-tandem mass spectrometry method for the determination of clarithromycin in human plasma
    van Rooyen, GF
    Smit, MJ
    de Jager, AD
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 768 (02): : 223 - 229
  • [4] Sensitive method for the determination of ibutilide in human plasma by liquid chromatography-tandem mass spectrometry
    Tian, L
    Li, YS
    Huang, YL
    Kuang, FH
    Li, F
    Hua, L
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 816 (1-2): : 81 - 85
  • [5] Sensitive and selective liquid chromatography-tandem mass spectrometry method for the quantification of azithromycin in human plasma
    Nirogi, RVS
    Kandikere, VN
    Shukla, M
    Mudigonda, K
    Maurya, S
    Boosi, R
    Yerramilli, A
    ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) : 1 - 8
  • [6] Sensitive and selective liquid chromatography-tandem mass spectrometry method for the quantification of aniracetam in human plasma
    Zhang, Jingjing
    Liang, Jidbi
    Tian, Yuan
    Zhang, Zunjian
    Chen, Yun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 858 (1-2): : 129 - 134
  • [7] Sensitive determination of phloroglucinol in human plasma by liquid chromatography-tandem mass spectrometry
    Hohyun Kim
    Sang Beom Han
    Chromatographia, 2003, 57 : 539 - 542
  • [8] Sensitive method for the quantitative determination of bromocriptine in human plasma by liquid chromatography-tandem mass spectrometry
    Salvador, A
    Dubreuil, D
    Denouel, J
    Millerioux, L
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (02): : 237 - 242
  • [9] Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of meloxicam in human plasma
    Wiesner, JL
    de Jager, AD
    Sutherland, FCW
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    Els, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (01): : 115 - 121
  • [10] Sensitive and rapid liquid chromatography-tandem mass spectrometry method for the determination of stavudine in human plasma
    Wiesner, JL
    Sutherland, FCW
    Smit, MJ
    van Essen, GH
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02): : 129 - 134