RapidBrachyMCTPS: a Monte Carlo-based treatment planning system for brachytherapy applications

被引:32
|
作者
Famulari, Gabriel [1 ]
Renaud, Marc-Andre [1 ]
Poole, Christopher M. [1 ,2 ]
Evans, Michael D. C. [1 ,3 ]
Seuntjens, Jan [1 ,4 ,5 ]
Enger, Shirin A. [1 ,4 ,5 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ H4A 3J1, Canada
[2] Radiat Analyt Pty Ltd, Mt Creek, Qld 4557, Australia
[3] McGill Univ, Hlth Ctr, Dept Med Phys, Montreal, PQ H4A 3J1, Canada
[4] McGill Univ, Dept Oncol, Montreal, PQ H4A 3J1, Canada
[5] McGill Univ, Hlth Ctr, Res Inst, Montreal, PQ H3H 2L9, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2018年 / 63卷 / 17期
基金
加拿大自然科学与工程研究理事会;
关键词
brachytherapy; model-based dose calculation algorithms; Monte Carlo; treatment planning; INTERSEED ATTENUATION; DOSE CALCULATIONS; HDR BRACHYTHERAPY; TISSUE COMPOSITION; DOSIMETRY; GEANT4; IR-192; EGSNRC; RECOMMENDATIONS; UNCERTAINTIES;
D O I
10.1088/1361-6560/aad97a
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Despite being considered the gold standard for brachytherapy dosimetry, Monte Carlo (MC) has yet to be implemented into a software for brachytherapy treatment planning. The purpose of this work is to present RapidBrachyMCTPS, a novel treatment planning system (TPS) for brachytherapy applications equipped with a graphical user interface (GUI), optimization tools and a Geant4based MC dose calculation engine, RapidBrachyMC. Brachytherapy sources and applicators were implemented in RapidBrachyMC and made available to the user via a source and applicator library in the GUI. To benchmark RapidBrachyMC, TG-43 parameters were calculated for the microSelectron v2 (Ir-192) and SelectSeed (I-125) source models and were compared against previously validated MC brachytherapy codes. The performance of RapidBrachyMC was evaluated for a prostate high dose rate case. To assess the accuracy of RapidBrachyMC in a heterogeneous setup, dose distributions with a cylindrical shielded/unshielded applicator were validated against film measurements in a Solid Water (TM) phantom. TG-43 parameters calculated using RapidBrachyMC generally agreed within 1%-2% of the results obtained in previously published work. For the prostate case, clinical dosimetric indices showed general agreement with Oncentra TPS within 1%. Simulation times were on the order of minutes on a single core to achieve uncertainties below 2% in voxels within the prostate. The calculation time was decreased further using the multithreading features of Geant4. In the comparison between MC-calculated and film-measured dose distributions, at least 95% of points passed the 3%/3 mm gamma index criteria in all but one case. RapidBrachyMCTPS can be used as a post-implant dosimetry toolkit, as well as for MC-based brachytherapy treatment planning. This software is especially well suited for the development of new source and applicator models.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Pre-Clinical Assessment of HDR Eye Plaque Treatment Using a Monte Carlo-Based Treatment Planning System
    Nunez, D. Aramburu
    Antaki, M.
    Morcos, M.
    Huang, S.
    Enger, S. Abbasinejad
    Barker, C.
    Damato, A.
    Cohen, G.
    MEDICAL PHYSICS, 2020, 47 (06) : E830 - E831
  • [22] Monitor unit calculation using the Monte Carlo-based oncentra masterplan planning system
    Quera Jordana, J.
    Fernandez-Velilla, E.
    Lozano, J.
    Vinals, P.
    Algara, M.
    Foro, P.
    Reig, A.
    Rodriguez, N.
    Sanz, X.
    Lacruz, M.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S418 - S418
  • [23] PATIENT-SPECIFIC MONTE CARLO-BASED DOSE-KERNEL APPROACH FOR INVERSE PLANNING IN AFTERLOADING BRACHYTHERAPY
    D'Amours, Michel
    Pouliot, Jean
    Dagnault, Anne
    Verhaegen, Frank
    Beaulieu, Luc
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : 1582 - 1589
  • [24] MONTE CARLO-BASED INVESTIGATION OF MICRODOSIMETRIC DISTRIBUTION OF HIGH ENERGY BRACHYTHERAPY SOURCES
    Chattaraj, Arghya
    Selvam, T. Palani
    Datta, D.
    RADIATION PROTECTION DOSIMETRY, 2019, 187 (01) : 115 - 128
  • [25] A Monte Carlo-based dosimetric characterization of Esteya®, an electronic surface brachytherapy unit
    Valdes-Cortez, Christian
    Niatsetski, Yury
    Perez-Calatayud, Jose
    Ballester, Facundo
    Vijande, Javier
    MEDICAL PHYSICS, 2019, 46 (01) : 356 - 369
  • [26] TOMOMC, A Monte Carlo-Based Planning Verification Tool for Helical Tomotherapy
    Chibani, O.
    Ma, C.
    MEDICAL PHYSICS, 2015, 42 (06) : 3512 - 3512
  • [27] Parameterization of brachytherapy source phase space file for Monte Carlo-based clinical brachytherapy dose calculation
    Zhang, M.
    Zou, W.
    Chen, T.
    Kim, L.
    Khan, A.
    Haffty, B.
    Yue, N. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (02): : 455 - 464
  • [28] Evaluation of RTOG Guidelines for Monte Carlo-based Lung SBRT Planning
    Zhung, J.
    Melian, E.
    Rusu, I.
    Nagda, S.
    Sethi, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S201 - S201
  • [29] Proton and helium ion radiotherapy for meningioma tumors: a Monte Carlo-based treatment planning comparison
    Thomas Tessonnier
    Andrea Mairani
    Wenjing Chen
    Paola Sala
    Francesco Cerutti
    Alfredo Ferrari
    Thomas Haberer
    Jürgen Debus
    Katia Parodi
    Radiation Oncology, 13
  • [30] Proton and helium ion radiotherapy for meningioma tumors: a Monte Carlo-based treatment planning comparison
    Tessonnier, Thomas
    Mairani, Andrea
    Chen, Wenjing
    Sala, Paola
    Cerutti, Francesco
    Ferrari, Alfredo
    Haberer, Thomas
    Debus, Juergen
    Parodi, Katia
    RADIATION ONCOLOGY, 2018, 13