MONTE CARLO-BASED INVESTIGATION OF MICRODOSIMETRIC DISTRIBUTION OF HIGH ENERGY BRACHYTHERAPY SOURCES

被引:9
|
作者
Chattaraj, Arghya [1 ,2 ]
Selvam, T. Palani [1 ,2 ]
Datta, D. [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Hlth Safety & Environm Grp, Radiol Phys & Advisory Div, Mumbai 400085, Maharashtra, India
[2] Homi Bhabha Natl Inst, Mumbai 400094, Maharashtra, India
关键词
RELATIVE BIOLOGICAL EFFECTIVENESS; SINGLE EVENT SPECTRA; CO-60; GAMMA-RAYS; WALL-LESS; X-RAYS; I-125; PD-103; SIMULATION; PARAMETERS; PHOTONS;
D O I
10.1093/rpd/ncz148
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
FLUKA-based Monte Carlo calculations were carried out to study microdosimetric distributions in air and in water for encapsulated high energy brachytherapy sources (Co-60, Cs-137, Ir-192 and Yb-169) by simulating a Tissue Equivalent Proportional Counter (Model LET1/2) having sensitive diameter of 1. 27 cm for a site size of 1 mu m. The study also included microdosimetric distributions of bare sources. When the sources are in air, for a given source, the source geometry does not affect the (y) over bar (F) and (y) over bar (D) values significantly. When the encapsulated Ir-192, Cs-137 and Co-60 sources are in water, (y) over bar (F) and (y) over bar (D) values increase with distance in water which is due to degradation in the energy of photons. Using the calculated values of (y) over bar, relative biological effectiveness (RBE) was obtained for the investigated sources. When Co-60, Cs-137 and Ir-192 sources are in water, RBE increases from 1.03 +/- 0.01 to 1.17 +/- 0.01, 1.24 +/- 0.01 to 1.46 +/- 0.02 and 1.50 +/- 0.01 to 1.75 +/- 0.03, respectively, when the distance was increased from 3-15 cm, whereas for Yb-169, RBE is about 2, independent of distance in water.
引用
收藏
页码:115 / 128
页数:14
相关论文
共 50 条
  • [1] Monte Carlo-based investigation of absorbed-dose energy dependence of radiochromic films in high energy brachytherapy dosimetry
    Subhalaxmi, Mishra
    Selvam, T. Palani
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 351 - 362
  • [2] RapidBrachyMCTPS: a Monte Carlo-based treatment planning system for brachytherapy applications
    Famulari, Gabriel
    Renaud, Marc-Andre
    Poole, Christopher M.
    Evans, Michael D. C.
    Seuntjens, Jan
    Enger, Shirin A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (17):
  • [3] Monte Carlo-based optimization of glioma capsule design for enhanced brachytherapy
    Li, Dongjie
    Liang, Yu
    Yao, Gang
    Guan, Zhongbao
    Zhao, Hongtao
    Zhang, Nan
    Jiang, Jicheng
    Gao, Weida
    APPLIED RADIATION AND ISOTOPES, 2023, 201
  • [4] Intratumoral Injection of Low-Energy Photon-Emitting Gold Nanoparticles: A Microdosimetric Monte Carlo-Based Model
    Laprise-Pelletier, Myriam
    Ma, Yunzhi
    Lagueux, Jean
    Cote, Marie-France
    Beaulieu, Luc
    Fortin, Marc-Andre
    ACS NANO, 2018, 12 (03) : 2482 - 2497
  • [5] Monte Carlo investigation of typical and potential sources for endovascular brachytherapy
    Lehmann, J
    Forster, KM
    Ma, CM
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 492 - 494
  • [6] A Monte Carlo-based dosimetric characterization of Esteya®, an electronic surface brachytherapy unit
    Valdes-Cortez, Christian
    Niatsetski, Yury
    Perez-Calatayud, Jose
    Ballester, Facundo
    Vijande, Javier
    MEDICAL PHYSICS, 2019, 46 (01) : 356 - 369
  • [7] Chronological Monte Carlo-based assessment of distribution system reliability
    Leite da Silva, Armando M.
    Cassula, Agnelo M.
    Nascimento, Luiz C.
    Freire, Jose C., Jr.
    Sacramento, Cleber E.
    Guimaraes, Ana Carolina R.
    2006 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS, VOLS 1 AND 2, 2006, : 1165 - 1171
  • [8] Parameterization of brachytherapy source phase space file for Monte Carlo-based clinical brachytherapy dose calculation
    Zhang, M.
    Zou, W.
    Chen, T.
    Kim, L.
    Khan, A.
    Haffty, B.
    Yue, N. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (02): : 455 - 464
  • [9] EGSnrc Monte Carlo calculated dose distribution around brachytherapy sources
    Tuan, Hoang
    Minh Phuoc Dang
    NUCLEAR MEDICINE AND BIOLOGY, 2022, 108 : S175 - S176
  • [10] Monte Carlo-based Adaptive Controller for Building Energy Efficiency
    Ge, Shuang
    Fu, Baochuan
    Wu, Zhengtian
    Wu, Yaqi
    2017 INTERNATIONAL SMART CITIES CONFERENCE (ISC2), 2017,