MONTE CARLO-BASED INVESTIGATION OF MICRODOSIMETRIC DISTRIBUTION OF HIGH ENERGY BRACHYTHERAPY SOURCES

被引:9
|
作者
Chattaraj, Arghya [1 ,2 ]
Selvam, T. Palani [1 ,2 ]
Datta, D. [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Hlth Safety & Environm Grp, Radiol Phys & Advisory Div, Mumbai 400085, Maharashtra, India
[2] Homi Bhabha Natl Inst, Mumbai 400094, Maharashtra, India
关键词
RELATIVE BIOLOGICAL EFFECTIVENESS; SINGLE EVENT SPECTRA; CO-60; GAMMA-RAYS; WALL-LESS; X-RAYS; I-125; PD-103; SIMULATION; PARAMETERS; PHOTONS;
D O I
10.1093/rpd/ncz148
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
FLUKA-based Monte Carlo calculations were carried out to study microdosimetric distributions in air and in water for encapsulated high energy brachytherapy sources (Co-60, Cs-137, Ir-192 and Yb-169) by simulating a Tissue Equivalent Proportional Counter (Model LET1/2) having sensitive diameter of 1. 27 cm for a site size of 1 mu m. The study also included microdosimetric distributions of bare sources. When the sources are in air, for a given source, the source geometry does not affect the (y) over bar (F) and (y) over bar (D) values significantly. When the encapsulated Ir-192, Cs-137 and Co-60 sources are in water, (y) over bar (F) and (y) over bar (D) values increase with distance in water which is due to degradation in the energy of photons. Using the calculated values of (y) over bar, relative biological effectiveness (RBE) was obtained for the investigated sources. When Co-60, Cs-137 and Ir-192 sources are in water, RBE increases from 1.03 +/- 0.01 to 1.17 +/- 0.01, 1.24 +/- 0.01 to 1.46 +/- 0.02 and 1.50 +/- 0.01 to 1.75 +/- 0.03, respectively, when the distance was increased from 3-15 cm, whereas for Yb-169, RBE is about 2, independent of distance in water.
引用
收藏
页码:115 / 128
页数:14
相关论文
共 50 条
  • [31] Experimental verification of a commercial Monte Carlo-based dose calculation module for high-energy photon beams
    Kuenzler, Thomas
    Fotina, Irina
    Stock, Markus
    Georg, Dietmar
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (24): : 7363 - 7377
  • [32] Monte Carlo-based simulation of dynamic jaws tomotherapy
    Sterpin, E.
    Chen, Y.
    Chen, Q.
    Lu, W.
    Mackie, T. R.
    Vynckier, S.
    MEDICAL PHYSICS, 2011, 38 (09) : 5230 - 5238
  • [33] NEWTON'S METHOD FOR MONTE CARLO-BASED RESIDUALS
    Willert, Jeffrey
    Chen, Xiaojun
    Kelley, C. T.
    SIAM JOURNAL ON NUMERICAL ANALYSIS, 2015, 53 (04) : 1738 - 1757
  • [34] Verification of a Monte Carlo-based treatment planning toot
    Chow, J.
    Leung, M.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S92 - S92
  • [35] Monte Carlo-based sensitivity analysis of an electrochemical capacitor
    Kannan, Vishvak
    Somasundaram, Karthik
    Fisher, Adrian
    Birgersson, Erik
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (11) : 16947 - 16962
  • [36] Prior Distribution Refinement for Reference Trajectory Estimation With the Monte Carlo-Based Localization Algorithm
    Griguletskii, Mark
    Shipitko, Oleg
    Abramov, Maxim
    Pristanskiy, Egor
    Kibalov, Vladislav
    Grigoryev, Anton
    IEEE ACCESS, 2023, 11 (19093-19102) : 19093 - 19102
  • [37] Advanced kernel methods vs. Monte Carlo-based dose calculation for high energy photon beams
    Fotina, Irina
    Winkler, Peter
    Kuenzler, Thomas
    Reiterer, Jochen
    Simmat, Isabell
    Georg, Dietmar
    RADIOTHERAPY AND ONCOLOGY, 2009, 93 (03) : 645 - 653
  • [38] Monte Carlo-based simulations of the formation of graphite oxide
    Paci, Jeffrey T.
    Belytschko, Ted
    Schatz, George C.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233
  • [39] Monte Carlo-based analysis of PET scatter components
    Adam, LE
    Bellemann, ME
    Brix, G
    Lorenz, WJ
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (12) : 2024 - 2029
  • [40] Monte Carlo-based scatter correction for the SMARTZOOM collimator
    Dietze, Martijn M. A.
    Kunnen, Britt
    Stella, Martina
    de Jong, Hugo W. A. M.
    EJNMMI PHYSICS, 2020, 7 (01)