Understanding the influence of three-dimensional sidewall roughness on observed line-edge roughness in scanning electron microscopy images

被引:3
|
作者
van Kessel, Luc [1 ]
Huisman, Thomas [2 ]
Hagen, Cornelis W. [1 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Delft, Netherlands
[2] ASML Netherlands BV, Veldhoven, Netherlands
来源
关键词
scanning electron microscopy; line edge roughness; sidewall roughness; metrology; Monte Carlo methods; SCATTERING; SURFACES; MODEL; SEM;
D O I
10.1117/1.JMM.19.3.034002
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Background: Line-edge roughness (LER) is often measured from top-down critical dimension scanning electron microscope (CD-SEM) images. The true three-dimensional roughness profile of the sidewall is typically ignored in such analyses. Aim: We study the response of a CD-SEM to sidewall roughness (SWR) by simulation. Approach: We generate random rough lines and spaces, where the SWR is modeled by a known power spectral density. We then obtain corresponding CD-SEM images using a Monte Carlo electron scattering simulator. We find the measured LER from these images and compare it to the known input roughness. Results: For isolated lines, the SEM measures the outermost extrusion of the rough sidewall. The result is that the measured LER is up to a factor of 2 less than the true on-wafer roughness. The effect can be modeled by making a top-down projection of the rough edge. Our model for isolated lines works fairly well for a dense grating of lines and spaces as long as the trench width exceeds the line height. Conclusions: In order to obtain and compare accurate LER values, the projection effect of SWR needs to be taken into account. (C) 2020 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Three-dimensional simulation of top down scanning electron microscopy images
    Grella, L
    Lorusso, G
    Lee, P
    Frank, F
    Adler, DL
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2004, 22 (06): : 3399 - 3404
  • [22] Three-dimensional reconstruction of a surface based on scanning electron microscopy images
    A. A. Mikhutkin
    A. L. Vasiliev
    Crystallography Reports, 2014, 59 : 908 - 915
  • [23] Three-dimensional analysis of scattering losses due to sidewall roughness, in microphotonic waveguides
    Barwicz, T
    Haus, HA
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2005, 23 (09) : 2719 - 2732
  • [24] Simulation of the Measurement by Scanning Electron Microscopy of Edge and Linewidth Roughness Parameters in Nanostructures
    Ciappa, Mauro
    Ilgunsatiroglu, Emre
    Illarionov, Alexey Yu.
    2015 JOINT INTERNATIONAL EUROSOI WORKSHOP AND INTERNATIONAL CONFERENCE ON ULTIMATE INTEGRATION ON SILICON (EUROSOI-ULIS), 2015, : 205 - 208
  • [26] Understanding the relationship between true and measured resist feature critical dimension and line edge roughness using a detailed scanning electron microscopy simulator
    Lawson, Richard A.
    Henderson, Clifford L.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2010, 28 (06): : C6H34 - C6H39
  • [27] Depth profile and line-edge roughness of low-molecular-weight amorphous electron beam resists
    Hirayama, T
    Shiono, D
    Matsumaru, S
    Ogata, T
    Hada, H
    Onodera, J
    Arai, T
    Sakamizu, T
    Yamaguchi, A
    Shiraishi, H
    Fukuda, H
    Ueda, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2005, 44 (7B): : 5484 - 5488
  • [29] Influence of three-dimensional wall roughness on the laminar flow in microtube
    Wang, Haoli
    Wang, Yuan
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2007, 28 (02) : 220 - 228
  • [30] Influence of irregular three-dimensional rough surfaces on the roughness function
    Scandura, Pietro
    JOURNAL OF FLUID MECHANICS, 2025, 1007