Determination of organochlorine pesticides in water samples by dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry

被引:87
|
作者
Cortada, Carol [3 ]
Vidal, Lorena [1 ,2 ]
Pastor, Raul [3 ]
Santiago, Noemi [3 ]
Canals, Antonio [1 ,2 ]
机构
[1] Univ Alicante, Dept Quim Analit Nutr & Bromatol, E-03080 Alicante, Spain
[2] Univ Alicante, Inst Univ Mat, E-03080 Alicante, Spain
[3] Labaqua SA, Alicante 03114, Spain
关键词
Organochlorine pesticides; Dispersive liquid-liquid microextraction; Sample preparation; Water samples analysis; ELECTRON-CAPTURE DETECTION; SINGLE-DROP MICROEXTRACTION; HOLLOW-FIBER MEMBRANE; PHASE MICROEXTRACTION; ORGANOPHOSPHORUS PESTICIDES; SENSITIVE METHOD; MATRICES;
D O I
10.1016/j.aca.2009.07.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and simple dispersive liquid-liquid microextraction (DLLME) has been developed to pre-concentrate eighteen organochlorine pesticides (OCPs) from water samples prior to analysis by gas chromatography-mass spectrometry (GC-MS). The studied variables were extraction solvent type and volume, disperser solvent type and volume. aqueous sample volume and temperature. The optimum experimental conditions of the proposed DLLME method were: a mixture of 10 mu L tetrachloroethylene (extraction solvent)and 1 mL acetone (disperser solvent) exposed for 30s to 10 mL of the aqueous sample at room temperature (20 degrees C). Centrifugation of cloudy solution was carried out at 2300 rpm for 3 min to allow phases separation. Finally, 2 mu L of extractant was recovered and injected into the GC-MS instrument. Under the optimum conditions, the enrichment factors ranged between 46 and 316. The calculated calibration curves gave a high-level linearity for all target analytes with correlation coefficients ranging between 0.9967 and 0.9999. The repeatability of the proposed method, expressed as relative standard deviation, varied between 5% and 15% (n = 8), and the detection limits were in the range of 1-25 ng L-1. The LOD values obtained are able to detect these OCPs in aqueous matrices as required by EPA methods 525.2 and 625. Analysis of spiked real water samples revealed that the matrix had no effect on extraction for river, surface and tap waters; however, urban wastewater sample shown a little effect for five out of eighteen analytes. V 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:218 / 221
页数:4
相关论文
共 50 条
  • [41] Determination of Phthalates in Milk by Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction and Gas Chromatography-Mass Spectrometry
    Tuncel, Semra G.
    Senlik, Damla
    [J]. ANALYTICAL LETTERS, 2016, 49 (09) : 1334 - 1343
  • [42] Dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry for the determination of pesticide residues in nutraceutical drops
    Szarka, Agnesa
    Turkova, Dominika
    Hrouzkova, Svetlana
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2018, 1570 : 126 - 134
  • [43] Temperature sensitive polymer-dispersive liquid-liquid microextraction with gas chromatography-mass spectrometry for the determination of phenols
    Chen, Xiaomei
    Guo, Zhian
    Wang, Yi
    Liu, Yufeng
    Xu, Yidong
    Liu, Jie
    Li, Zhiqiang
    Zhao, Jingchan
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2019, 1592 : 183 - 187
  • [44] Dispersive liquid-liquid microextraction using a low transition temperature mixture and liquid chromatography-mass spectrometry analysis of pesticides in urine samples
    Gallo, Valeria
    Tomai, Pierpaolo
    Gherardi, Monica
    Fanali, Chiara
    De Gara, Laura
    D'Orazio, Giovanni
    Gentili, Alessandra
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2021, 1642
  • [45] Determination of Seven Antidepressants in Pericardial Fluid by Means of Dispersive Liquid-Liquid Microextraction and Gas Chromatography-Mass Spectrometry
    Cabarcos-Fernandez, P.
    Tabernero-Duque, M. J.
    Alvarez-Freire, I
    Bermejo-Barrera, A. M.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2022, 46 (02) : 146 - 156
  • [46] Determination of trace azo dyes in textile wastewater by liquid-liquid extraction and dispersive liquid. liquid microextraction coupled with gas chromatography-mass spectrometry
    Ye Xiwen
    He Jing
    Li Ying
    Niu Zengyuan
    Zhang Tiantian
    Luo Xin
    Zou Li
    Lian Sumei
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (02) : 255 - 263
  • [47] Solvent demulsification-dispersive liquid-liquid microextraction based on solidification of floating organic drop coupled with gas chromatography. mass spectrometry for simultaneous determination of organochlorine pesticides in aqueous samples
    Wang Yu
    Zhu Chenghua
    Zou Xiaoli
    Huang Lizhi
    Yan Dong
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (11) : 1076 - 1080
  • [48] Rapid determination of anilines in water samples by dispersive liquid-liquid microextraction based on solidification of floating organic drop prior to gas chromatography-mass spectrometry
    Diao, Chun-Peng
    Wei, Chao-Hai
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (03) : 877 - 884
  • [49] Homogeneous Liquid-Liquid Microextraction for Determination of Organochlorine Pesticides in Water and Fruit Samples
    Yazdanfar, Najmeh
    Yamini, Yadollah
    Ghambarian, Mahnaz
    [J]. CHROMATOGRAPHIA, 2014, 77 (3-4) : 329 - 336
  • [50] Determination of Phorate in Water Using Dispersive Liquid-Liquid Microextraction Coupled with Gas Chromatography
    Xie Hong-Xue
    He Li-Jun
    Wu Xiu-Ling
    Fan Lu
    Lu Kui
    Wang Mei-Mei
    Meng Da-Wei
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (11) : 1543 - 1546