Determination of organochlorine pesticides in water samples by dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry

被引:90
|
作者
Cortada, Carol [3 ]
Vidal, Lorena [1 ,2 ]
Pastor, Raul [3 ]
Santiago, Noemi [3 ]
Canals, Antonio [1 ,2 ]
机构
[1] Univ Alicante, Dept Quim Analit Nutr & Bromatol, E-03080 Alicante, Spain
[2] Univ Alicante, Inst Univ Mat, E-03080 Alicante, Spain
[3] Labaqua SA, Alicante 03114, Spain
关键词
Organochlorine pesticides; Dispersive liquid-liquid microextraction; Sample preparation; Water samples analysis; ELECTRON-CAPTURE DETECTION; SINGLE-DROP MICROEXTRACTION; HOLLOW-FIBER MEMBRANE; PHASE MICROEXTRACTION; ORGANOPHOSPHORUS PESTICIDES; SENSITIVE METHOD; MATRICES;
D O I
10.1016/j.aca.2009.07.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and simple dispersive liquid-liquid microextraction (DLLME) has been developed to pre-concentrate eighteen organochlorine pesticides (OCPs) from water samples prior to analysis by gas chromatography-mass spectrometry (GC-MS). The studied variables were extraction solvent type and volume, disperser solvent type and volume. aqueous sample volume and temperature. The optimum experimental conditions of the proposed DLLME method were: a mixture of 10 mu L tetrachloroethylene (extraction solvent)and 1 mL acetone (disperser solvent) exposed for 30s to 10 mL of the aqueous sample at room temperature (20 degrees C). Centrifugation of cloudy solution was carried out at 2300 rpm for 3 min to allow phases separation. Finally, 2 mu L of extractant was recovered and injected into the GC-MS instrument. Under the optimum conditions, the enrichment factors ranged between 46 and 316. The calculated calibration curves gave a high-level linearity for all target analytes with correlation coefficients ranging between 0.9967 and 0.9999. The repeatability of the proposed method, expressed as relative standard deviation, varied between 5% and 15% (n = 8), and the detection limits were in the range of 1-25 ng L-1. The LOD values obtained are able to detect these OCPs in aqueous matrices as required by EPA methods 525.2 and 625. Analysis of spiked real water samples revealed that the matrix had no effect on extraction for river, surface and tap waters; however, urban wastewater sample shown a little effect for five out of eighteen analytes. V 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:218 / 221
页数:4
相关论文
共 50 条
  • [11] Dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry for the determination of nitro musks in surface water and wastewater samples
    Lopez-Nogueroles, M.
    Chisvert, A.
    Salvador, A.
    Carretero, A.
    TALANTA, 2011, 85 (04) : 1990 - 1995
  • [12] Simultaneous determination of seven preservatives in food by dispersive liquid-liquid microextraction coupled with gas chromatography-mass spectrometry
    Ding, Mingzhen
    Liu, Weixi
    Peng, Jing
    Liu, Xiuhong
    Tang, Yu
    FOOD CHEMISTRY, 2018, 269 : 187 - 192
  • [13] Determination of benzotriazoles in water samples by concurrent derivatization-dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry
    Casado, J.
    Nescatelli, R.
    Rodriguez, I.
    Ramil, M.
    Marini, F.
    Cela, R.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1336 : 1 - 9
  • [14] Rapid determination of amide herbicides in environmental water samples with dispersive liquid-liquid microextraction prior to gas chromatography-mass spectrometry
    Zhao, Ru-Song
    Diao, Chun-Peng
    Wang, Xia
    Jiang, Ting
    Yuan, Jin-Peng
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (08) : 2915 - 2921
  • [15] Microwave-assisted-demulsification-dispersive liquid-liquid microextraction coupled with gas chromatography-mass spectrometry for the determination of PAHs in water
    Wang, Xiajun
    Nie, Jing
    Yu, Guowei
    Wang, Peng
    Li, Zuguang
    Lee, Mawrong
    ANALYTICAL METHODS, 2018, 10 (42) : 5105 - 5111
  • [16] Dual dispersive liquid-liquid microextraction for determination of phenylpropenes in oils by gas chromatography-mass spectrometry
    Tsai, Chia-Ju
    Li, Jih-Heng
    Feng, Chia-Hsien
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1410 : 60 - 67
  • [17] Determination of organophosphorus pesticides in wastewater samples using vortex-assisted dispersive liquid-liquid microextraction with liquid chromatography-mass spectrometry
    Muckoya, V. A.
    Nomngongo, P. N.
    Ngila, J. C.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2020, 17 (04) : 2325 - 2336
  • [18] Speciation of butyltins by dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry
    Smitiene, Vaida
    Baskirova, Inga
    Vickackaite, Vida
    CHEMIJA, 2013, 24 (03): : 210 - 216
  • [19] Automated Dispersive Liquid-Liquid Microextraction-Gas Chromatography-Mass Spectrometry
    Guo, Liang
    Lee, Hian Kee
    ANALYTICAL CHEMISTRY, 2014, 86 (08) : 3743 - 3749
  • [20] Application of dispersive liquid–liquid microextraction for the determination of selected organochlorine pesticides in honey by gas chromatography–mass spectrometry
    Maciej W. Kujawski
    Emilie Pinteaux
    Jacek Namieśnik
    European Food Research and Technology, 2012, 234 : 223 - 230