Time-resolved fluoroimmunoassay of plasma and urine O-desmethylangolensin

被引:17
|
作者
L'homme, R
Brouwers, E
Al-Maharik, N
Lapcík, O
Hampl, R
Mikola, H
Wähälä, K
Adlercreutz, H
机构
[1] Univ Helsinki, Folkhalsan Res Ctr, Div Clin Chem, FIN-00014 Helsinki, Finland
[2] Univ Helsinki, Folkhalsan Res Ctr, Inst Prevent Med, FIN-00014 Helsinki, Finland
[3] Univ Helsinki, Dept Chem, Organ Chem Lab, FIN-00014 Helsinki, Finland
[4] Inst Chem, Dept Chem Nat Subst, Prague 16628 6, Czech Republic
[5] Inst Endocrinol, Prague 11694 1, Czech Republic
[6] Wallac Oy, FIN-20101 Turku, Finland
关键词
immunoassay; phytoestrogens; isofavones; urine; O-desmethylangolensin; fluorometry;
D O I
10.1016/S0960-0760(02)00073-0
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We present a method for the determination of the phytoestrogen metabolite O-desmethylangolensin (O-DMA) in plasma (serum) and in urine. O-DMA is a metabolite of daidzein, which occurs in soybeans. It has been suggested that isoflavones may afford protection against breast and prostate cancer and therefore, also the metabolites are of interest. The method is based on time-resolved fluoroimmunoassay (TR-FIA) using a europium chelate as a label. After the synthesis of 4"-O-carboxymethyl-O-DMA, this compound is coupled to bovine serum albumin, and then used as antigen in immunization of rabbits. The tracers with the europium chelate are synthesized using the same 4"-O-derivative of the alpha-methyldeoxybenzoin. After enzymatic hydrolysis and ether extraction the immunoassay is carried out by time resolved fluoroimmunoassay (TR-FIA). Cross-reactivity was tested with angolensin, dihydrogenistein, dihydrodaidzein, equol, 6'-OH-angolensin, trans-4-OH-equol, 6'-OH-O-DMA, cis-4-OH-equol and 5-OH-equol. The antiserum cross-reacted only with angolensin. This cross-reactivity seems not to influence the results, which were highly specific. Plasma samples are hydrolyzed and extracted. Urine samples are analyzed directly after hydrolysis without extraction. The correlation coefficient between the plasma TR-FIA results and the GC-MS results was high; r value was 0.985. The correlation coefficient between the urine TR-FIA results and the GC-MS results was high over the entire range of concentrations (0-1500 nmol/l); r value was 0.976, but lower in the low concentration range (0-100 nmol/l), i.e. value was 0.631. The intra-assay coefficients of variation (CVs) for plasma O-DMA concentrations and for urine O-DMA concentrations at three different concentrations varied 2.8-7.7 and 3.0-6.0%, respectively and the inter-assay CVs varied 3.8-8.9 and 4.4-6.6%, respectively. The working range of the plasma and urine O-DMA assays was 0.5-512 nmol/l. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:353 / 361
页数:9
相关论文
共 50 条
  • [31] APPLICATION OF SYNERGETIC LUMINESCENCE TO TIME-RESOLVED FLUOROIMMUNOASSAY
    LI, JJ
    CHEN, GQ
    ZENG, YE
    [J]. CHINESE SCIENCE BULLETIN, 1992, 37 (01): : 84 - 85
  • [32] Development of a Competitive Time-Resolved Fluoroimmunoassay for Paclitaxel
    Cui, Qian
    Tanaka, Hiroyuki
    Shoyama, Yukihiro
    Ye, Hao-Ting
    Li, Fang
    Tian, En-Wei
    Wu, Ying-Song
    Chao, Zhi
    [J]. PHYTOCHEMICAL ANALYSIS, 2018, 29 (03) : 284 - 289
  • [33] Development of time-resolved fluoroimmunoassay with enhanced fluorescence reaction for the quantitation of atezolizumab in plasma
    Darwish, Ibrahim A.
    Alzoman, Nourah Z.
    Khalil, Nehal N.
    Alsalhi, Mohammed S.
    [J]. LUMINESCENCE, 2024, 39 (05)
  • [34] Time-resolved fluoroimmunoassay of CA125
    Cai, G.M.
    Huang, B.
    Zhu, L.G.
    Xiao, H.L.
    Tan, C.
    Tao, Y.H.
    Jin, J.
    [J]. 2001, Science Press (24):
  • [35] Time-resolved fluoroimmunoassay for ractopamine in swine tissue
    Shen, Jianzhong
    Zhang, Zhen
    Yao, Yan
    Shi, Weimin
    Liu, Yibing
    Zhang, Suxia
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (04) : 1561 - 1564
  • [36] Stereochemical determination of O-desmethylangolensin produced from daidzein
    Niwa, Toshio
    Yokoyama, Shin-ichiro
    Matsugasaki, Natsuki
    Inomata, Eri
    Taira, Asako
    Osawa, Toshihiko
    [J]. FOOD CHEMISTRY, 2015, 171 : 153 - 156
  • [37] Comparison of plasma and urinary phytoestrogens in Japanese and Finnish women by time-resolved fluoroimmunoassay
    Uehara, M
    Arai, Y
    Watanabe, S
    Adlercreutz, H
    [J]. BIOFACTORS, 2000, 12 (1-4) : 217 - 225
  • [38] Metabolomics profiles of premenopausal women are different based on O-desmethylangolensin metabotype
    Frankenfeld, Cara L.
    Maskarinec, Gertraud
    Franke, Adrian A.
    [J]. BRITISH JOURNAL OF NUTRITION, 2022, 128 (08) : 1490 - 1498
  • [39] Development of a dual label time-resolved fluoroimmunoassay for the detection of beta-agonists in cattle urine
    Elliott, CT
    Baxter, A
    Haasnoot, W
    Lommen, A
    McCaughey, WJ
    [J]. FOOD AND AGRICULTURAL IMMUNOLOGY, 1996, 8 (04) : 219 - 227
  • [40] Detection of anticardiolipin antibody IgG by time-resolved fluoroimmunoassay
    Ye, Yan
    Hu, Zhigang
    Liu, Jie
    Chen, Guoqian
    Zhou, Yaohong
    Yu, Lei
    [J]. CLINICAL RHEUMATOLOGY, 2012, 31 (09) : 1339 - 1345