Development of time-resolved fluoroimmunoassay with enhanced fluorescence reaction for the quantitation of atezolizumab in plasma

被引:0
|
作者
Darwish, Ibrahim A. [1 ]
Alzoman, Nourah Z. [1 ]
Khalil, Nehal N. [1 ]
Alsalhi, Mohammed S. [1 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, POB 2457, Riyadh 11451, Saudi Arabia
关键词
atezolizumab; cancer immunotherapy; immune-checkpoint inhibitors; therapeutic drug monitoring; therapeutic monoclonal antibodies; TRFIA; MONOCLONAL-ANTIBODIES; MASS-TRANSPORT; BIOANALYSIS; IMMUNOASSAYS; KINETICS; PD-L1; ELISA;
D O I
10.1002/bio.4747
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Atezolizumab (ATZ) is a human monoclonal antibody, which has been granted multiple approvals from the US Food and Drug Administration (FDA) for the immunotherapy of different types of cancer. This study describes the prototype of a time-resolved fluoroimmunoassay (TRFIA) for the quantitation of ATZ in plasma. The assay involved the non-competitive binding of ATZ to its specific antigen [programmed death-ligand 1 (PD-L1) protein]. The immune complex formed on the inner surface of the assay plate wells was quantified by anti-human secondary antibody labeled with a chelate of europium-ethylenediaminetetraacetic acid. The enhanced fluorescence signal was generated by an enhanced fluorescence solution composed of thenoyltrifluoroacetone, trioctylphosphine oxide, and Triton X-100. The conditions of the TRFIA were refined, and its optimum procedures were established. The assay was validated in accordance with the immunoassay validation guidelines, and all the validation parameters were acceptable. The working range of the assay was 20-1000 pg mL-1, and its limit of quantitation was 20 pg mL-1. The assay was applied to the quantitation of ATZ in plasma samples with satisfactory accuracy and precision. The proposed TRFIA has significant benefits over the existing methodologies for the quantitation of ATZ in clinical settings. A novel ultrasensitive time-resolved fluoroimmunoassay (TRFIA) for the quantitation of atezolizumab (ATZ) in plasma. The assay involved the non-competitive binding of ATZ to its specific antigen [programmed death-ligand 1 (PD-L1) protein]. The immune complex formed on the inner surface of the assay plate wells was quantified by anti-human secondary antibody labeled with a chelate of europium-ethylenediaminetetraacetic acid. The enhanced fluorescence signal was generated by an enhanced fluorescence solution. The signals were correlated with the ATZ concentrations. image
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Time-resolved fluoroimmunoassay for plasma enterolactone
    Adlercreutz, H
    Wang, GJJ
    Lapcík, O
    Hampl, R
    Wähälä, K
    Mäkelä, T
    Lusa, K
    Talme, M
    Mikola, H
    [J]. ANALYTICAL BIOCHEMISTRY, 1998, 265 (02) : 208 - 215
  • [2] A prototype of ultrasensitive time-resolved fluoroimmunoassay for the quantitation of lead in plasma using a fluorescence-enhanced europium chelate label for the detection system
    Darwish, Ibrahim A.
    Suzuki, Kenzi
    Ogawa, Hiroshi
    Wang, Zongzhi
    [J]. RSC ADVANCES, 2024, 14 (13) : 8671 - 8683
  • [3] TIME-RESOLVED FLUOROIMMUNOASSAY FOR SECRETIN IN HUMAN PLASMA
    ITO, K
    MAEDA, M
    TSUJI, A
    [J]. BUNSEKI KAGAKU, 1992, 41 (12) : 627 - 632
  • [4] Time-resolved fluoroimmunoassay for equol in plasma and urine
    Brouwers, E
    L'homme, R
    Al-Maharik, N
    Lapcík, O
    Hampl, R
    Wähälä, K
    Mikola, H
    Adlercreutz, H
    [J]. JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2003, 84 (05): : 577 - 588
  • [5] Time-resolved fluoroimmunoassay of plasma daidzein and genistein
    Wang, GJ
    Lapcík, O
    Hampl, R
    Uehara, M
    Al-Maharik, N
    Stumpf, K
    Mikola, H
    Wähälä, K
    Adlercreutz, H
    [J]. STEROIDS, 2000, 65 (06) : 339 - 348
  • [6] Changes in the time-resolved fluoroimmunoassay of plasma enterolactone
    Stumpf, K
    Uehara, M
    Nurmi, T
    Adlercreutz, H
    [J]. ANALYTICAL BIOCHEMISTRY, 2000, 284 (01) : 153 - 157
  • [7] Time-resolved fluoroimmunoassay
    Degan, P
    Podestà, A
    Montagnoli, G
    [J]. MOLECULAR BIOTECHNOLOGY, 1999, 13 (03) : 215 - 222
  • [8] Time-resolved fluoroimmunoassay
    Paolo Degan
    Adriano Podestà
    Giorgio Montagnoli
    [J]. Molecular Biotechnology, 1999, 13 : 215 - 222
  • [9] DEVELOPMENT OF A TIME-RESOLVED FLUOROIMMUNOASSAY FOR SERUM MYOGLOBIN
    MANNILA, A
    HEMMILA, I
    LOVGREN, T
    ZEUTHEN, J
    MARNIEMI, J
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1986, 46 : 182 - 182
  • [10] Development of a Competitive Time-Resolved Fluoroimmunoassay for Paclitaxel
    Cui, Qian
    Tanaka, Hiroyuki
    Shoyama, Yukihiro
    Ye, Hao-Ting
    Li, Fang
    Tian, En-Wei
    Wu, Ying-Song
    Chao, Zhi
    [J]. PHYTOCHEMICAL ANALYSIS, 2018, 29 (03) : 284 - 289