Four-dimensional measurement of intrafractional respiratory motion of pancreatic tumors using a 256 multi-slice CT scanner

被引:69
|
作者
Mori, Shinichiro [1 ]
Hara, Ryusuke
Yanagi, Takeshi
Sharp, Gregory C. [2 ]
Kumagai, Motoki
Asakura, Hiroshi [3 ]
Kishimoto, Riwa
Yamada, Shigeru
Kandatsu, Susumu
Kamada, Tadashi
机构
[1] Natl Inst Radiol Sci, Res Ctr Charged Particle Therapy, Inage Ku, Chiba 2638555, Japan
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[3] Accelerator Engn Corp, Chiba, Japan
关键词
Carbon beam; CT; Four-dimensional; Pancreas; Radiation therapy; HEAVY-ION RADIOTHERAPY; CELL LUNG-CANCER; PERFORMANCE EVALUATION; DOSE-ESCALATION; THERAPY; RADIATION; IRRADIATION; MOVEMENT; SYSTEM; LIVER;
D O I
10.1016/j.radonc.2008.12.015
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify pancreas and pancreatic tumor movement due to respiratory motion using volumetric cine CT images. Materials and methods: Six patients with pancreatic tumors were scanned in cine mode with a 256 multi-slice CT scanner under free breathing conditions. Gross tumor volume (GTV) and pancreas were manually contoured on the CT data set by a radiation oncologist. Intrafractional respiratory movement of the GTV and pancreas was calculated, and the results were compared between the respiratory ungated and gated phases, which is a 30% duty cycle around exhalation. Results: Respiratory-induced organ motion was observed mainly in the anterior abdominal side than the posterior side. Average GTV displacement (ungated/gated phases) was 0.7 mm/0.2 mm in both the left and right directions, and 2.5 mm/0.9 mm in the anterior, 0.1 mm/0 mm in the posterior, and 8.9 mm/2.6 mm in the inferior directions. Average pancreas center of mass displacement relative to that at peak exhalation was mainly in the inferior direction, at 9.6 mm in the ungated phase and 2.3 mm in the gated phase. Conclusions: By allowing accurate determination of the margin, quantitative analysis of tumor and pancreas displacement provides useful information in treatment planning in all radiation approaches for pancreatic tumors. (C) 2009 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 92 (2009) 231-237
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [31] Evaluation of Four Data-Driven Respiratory Motion-Compensation Methods for Four-Dimensional Cone-Beam CT Registration and Reconstruction
    Riblett, M. J.
    Christensen, G. E.
    Hugo, G. D.
    MEDICAL PHYSICS, 2015, 42 (06) : 3730 - 3730
  • [32] Strain measurement on four-dimensional dynamic-ventilation CT: quantitative analysis of abnormal respiratory deformation of the lung in COPD
    Xu, Yanyan
    Yamashiro, Tsuneo
    Moriya, Hiroshi
    Tsubakimoto, Maho
    Nagatani, Yukihiro
    Matsuoka, Shin
    Murayama, Sadayuki
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2019, 14 : 65 - 72
  • [33] Evaluation of the respiratory prostate motion with four-dimensional computed tomography scan acquisitions using three implanted markers
    Udrescu, Corina
    Jalade, Patrice
    de Bari, Berardino
    Michel-Amadry, Geraldine
    Chapet, Olivier
    RADIOTHERAPY AND ONCOLOGY, 2012, 103 (02) : 266 - 269
  • [34] Assessment of the Respiratory Motion Induced Inter-Sessional Liver Positional Variation Using Four-Dimensional MR
    Zhou, Y.
    Wong, O. L.
    Yuan, J.
    Cheung, K. Y.
    Yu, S. K.
    MEDICAL PHYSICS, 2017, 44 (06) : 3040 - 3040
  • [35] Quantification of Respiratory Induced Dose Variation in Heavy Charged Particle Prostate Therapy Using Four-dimensional CT
    Kumagai, M.
    Mori, S.
    Okada, T.
    Asakura, H.
    Kandatsu, S.
    Tsuji, H.
    Kamada, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S808 - S809
  • [36] Evaluation of Interfractional and Intrafractional Tumor Motion in Stereotactic Liver Radiotherapy, Based On Four-Dimensional Cone-Beam Computed Tomography Using Fiducial Markers
    Shimohigashi, Y.
    Araki, F.
    Toya, R.
    Maruyama, M.
    Nakaguchi, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3682 - 3682
  • [37] Study On the Method and Accuracy of Volume Delineation and Motion Amplitude Measurement Based On Four-Dimensional CT Images Under Different Breathing Motion Modes
    Ni, Q.
    MEDICAL PHYSICS, 2022, 49 (06) : E781 - E782
  • [38] Four-Dimensional Motion Correction to Distinguish Respiratory From Biological Changes in Treatment Response Assessment Using Molecular Imaging
    Fox, T.
    Crocker, I.
    Schuster, D.
    Curran, W.
    Schreibmann, E.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [39] The use of respiratory-correlated four-dimensional CT where kidney motion has the potential to impact upon the radiotherapy planning process
    Gawthrop, Janet B.
    Gill, Suki
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2012, 56 (06) : 689 - 695
  • [40] Assessment of intrafraction mediastinal and hilar lymph node movement and comparison to lung tumor motion using four-dimensional CT
    Donnelly, Eric D.
    Parikh, Parag J.
    Lu, Wei
    Zhao, Tianyu
    Lechleiter, Kristen
    Nystrom, Michelle
    Hubenschmidt, James P.
    Low, Daniel A.
    Bradley, Jeffrey D.