Four-dimensional measurement of intrafractional respiratory motion of pancreatic tumors using a 256 multi-slice CT scanner

被引:69
|
作者
Mori, Shinichiro [1 ]
Hara, Ryusuke
Yanagi, Takeshi
Sharp, Gregory C. [2 ]
Kumagai, Motoki
Asakura, Hiroshi [3 ]
Kishimoto, Riwa
Yamada, Shigeru
Kandatsu, Susumu
Kamada, Tadashi
机构
[1] Natl Inst Radiol Sci, Res Ctr Charged Particle Therapy, Inage Ku, Chiba 2638555, Japan
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[3] Accelerator Engn Corp, Chiba, Japan
关键词
Carbon beam; CT; Four-dimensional; Pancreas; Radiation therapy; HEAVY-ION RADIOTHERAPY; CELL LUNG-CANCER; PERFORMANCE EVALUATION; DOSE-ESCALATION; THERAPY; RADIATION; IRRADIATION; MOVEMENT; SYSTEM; LIVER;
D O I
10.1016/j.radonc.2008.12.015
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify pancreas and pancreatic tumor movement due to respiratory motion using volumetric cine CT images. Materials and methods: Six patients with pancreatic tumors were scanned in cine mode with a 256 multi-slice CT scanner under free breathing conditions. Gross tumor volume (GTV) and pancreas were manually contoured on the CT data set by a radiation oncologist. Intrafractional respiratory movement of the GTV and pancreas was calculated, and the results were compared between the respiratory ungated and gated phases, which is a 30% duty cycle around exhalation. Results: Respiratory-induced organ motion was observed mainly in the anterior abdominal side than the posterior side. Average GTV displacement (ungated/gated phases) was 0.7 mm/0.2 mm in both the left and right directions, and 2.5 mm/0.9 mm in the anterior, 0.1 mm/0 mm in the posterior, and 8.9 mm/2.6 mm in the inferior directions. Average pancreas center of mass displacement relative to that at peak exhalation was mainly in the inferior direction, at 9.6 mm in the ungated phase and 2.3 mm in the gated phase. Conclusions: By allowing accurate determination of the margin, quantitative analysis of tumor and pancreas displacement provides useful information in treatment planning in all radiation approaches for pancreatic tumors. (C) 2009 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 92 (2009) 231-237
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [21] Respiratory motion of lymph node stations in pancreatic cancer: Analyses using contrast-enhanced four-dimensional computed tomography
    Takahashi, Shigeo
    Anada, Masahide
    Kinoshita, Toshifumi
    Shibata, Toru
    RADIOTHERAPY AND ONCOLOGY, 2018, 128 (03) : 569 - 574
  • [22] Self-Sorted Four-Dimensional CT Using Body Volume as Respiratory Surrogate
    Cai, J.
    Chang, Z.
    Yin, F.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [23] Three-dimensional visualization of diffuse lung disease using multi-slice CT data set
    Akahane, M
    Minami, M
    Miyazawa, M
    Kiryu, S
    Kunimatsu, A
    Ohtomo, K
    RADIOLOGY, 2000, 217 : 123 - 123
  • [24] Respiratory motion of adrenal gland metastases: Analyses using four-dimensional computed tomography images
    Chen, Bing
    Hu, Yong
    Liu, Jin
    Cao, An-Ning
    Ye, Lu-Xi
    Zeng, Zhao-Chong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 38 : 54 - 58
  • [25] Four-Dimensional CT-Based Evaluation of Intrafractional and Interfractional Anastomosis Motion During Postoperative Radiation Therapy in Gastric Cancer: A Prospective Study
    Liu, W.
    Jin, J.
    Ren, H.
    Fang, H.
    Li, Y.
    Wang, W.
    Wang, S.
    Song, Y.
    Liu, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S869 - S869
  • [26] Improved temporal resolution by respiratory gated segment reconstruction: Towards four-dimensional (4D) radiation therapy for heavy ion beams using the 256-detector-row CT-scanner
    Mori, S
    Kohn, R
    Asakura, H
    Kohno, K
    Minohara, S
    Endo, M
    MEDICAL PHYSICS, 2005, 32 (06) : 1924 - 1924
  • [27] Improved temporal resolution by a respiratory gated segment reconstruction: towards four-dimensional (4D) radiation therapy for heavy ion beams using the 256-detector-row CT-scanner
    Shinichiro, M.
    Mori, M.
    Kohn, K. K.
    Asakura, A. H.
    Endo, E. M.
    EJC SUPPLEMENTS, 2005, 3 (02): : 395 - 396
  • [28] Four-Dimensional Computed Tomography-Based Correlation of Respiratory Motion of Lung Tumors With Implanted Fiducials and an External Surrogate
    Willmann, Jonas
    Sidiqi, Baho
    Wang, Chunyu
    Czmielewski, Christian
    Li, Henry J.
    Dick-Godfrey, Rosalind
    Chawla, Mohit
    Lee, Robert P.
    Gelb, Emily
    Wu, Abraham J.
    Lovelock, Michael
    Zhang, Zhigang
    Yorke, Ellen D.
    Rimner, Andreas
    ADVANCES IN RADIATION ONCOLOGY, 2022, 7 (03)
  • [29] Respiratory-gated segment reconstruction for radiation treatment planning using 256-slice CT-scanner during free breathing
    Mori, S
    Endo, M
    Kohno, R
    Minohara, S
    Kohno, K
    Asakura, H
    Fujiwara, H
    Murase, K
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 711 - 721
  • [30] Evaluation of pisotriquetral motion pattern using four-dimensional CT: initial clinical experience in asymptomatic wrists
    Demehri, S.
    Hafezi-Nejad, N.
    Thakur, U.
    Morelli, J. N.
    Lifchez, S. D.
    Means, K. R.
    Shores, J. T.
    CLINICAL RADIOLOGY, 2015, 70 (12) : 1362 - 1369