Four-dimensional measurement of intrafractional respiratory motion of pancreatic tumors using a 256 multi-slice CT scanner

被引:69
|
作者
Mori, Shinichiro [1 ]
Hara, Ryusuke
Yanagi, Takeshi
Sharp, Gregory C. [2 ]
Kumagai, Motoki
Asakura, Hiroshi [3 ]
Kishimoto, Riwa
Yamada, Shigeru
Kandatsu, Susumu
Kamada, Tadashi
机构
[1] Natl Inst Radiol Sci, Res Ctr Charged Particle Therapy, Inage Ku, Chiba 2638555, Japan
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[3] Accelerator Engn Corp, Chiba, Japan
关键词
Carbon beam; CT; Four-dimensional; Pancreas; Radiation therapy; HEAVY-ION RADIOTHERAPY; CELL LUNG-CANCER; PERFORMANCE EVALUATION; DOSE-ESCALATION; THERAPY; RADIATION; IRRADIATION; MOVEMENT; SYSTEM; LIVER;
D O I
10.1016/j.radonc.2008.12.015
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify pancreas and pancreatic tumor movement due to respiratory motion using volumetric cine CT images. Materials and methods: Six patients with pancreatic tumors were scanned in cine mode with a 256 multi-slice CT scanner under free breathing conditions. Gross tumor volume (GTV) and pancreas were manually contoured on the CT data set by a radiation oncologist. Intrafractional respiratory movement of the GTV and pancreas was calculated, and the results were compared between the respiratory ungated and gated phases, which is a 30% duty cycle around exhalation. Results: Respiratory-induced organ motion was observed mainly in the anterior abdominal side than the posterior side. Average GTV displacement (ungated/gated phases) was 0.7 mm/0.2 mm in both the left and right directions, and 2.5 mm/0.9 mm in the anterior, 0.1 mm/0 mm in the posterior, and 8.9 mm/2.6 mm in the inferior directions. Average pancreas center of mass displacement relative to that at peak exhalation was mainly in the inferior direction, at 9.6 mm in the ungated phase and 2.3 mm in the gated phase. Conclusions: By allowing accurate determination of the margin, quantitative analysis of tumor and pancreas displacement provides useful information in treatment planning in all radiation approaches for pancreatic tumors. (C) 2009 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 92 (2009) 231-237
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [1] Four-dimensional measurement of lung tumor displacement using 256-multi-slice CT-scanner
    Mori, Shinichiro
    Endo, Masahiro
    Komatsu, Shuhei
    Yashiro, Tomoyasu
    Kandatsu, Susumu
    Baba, Masayuki
    LUNG CANCER, 2007, 56 (01) : 59 - 67
  • [2] Development of software for four-dimensional cardiac function analysis using multi-slice CT scanner
    Yamamoto, S
    Hamada, S
    Naito, H
    Johkoh, T
    Miyamoto, M
    Masumoto, J
    Azemoto, S
    Kanagawa, T
    Nakanishi, S
    Nakamura, H
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 934 - 939
  • [3] Physical performance evaluation of a 256-slice CT-scanner for four-dimensional imaging
    Mori, S
    Endo, M
    Tsunoo, T
    Kandatsu, S
    Tanada, S
    Aradate, H
    Saito, Y
    Miyazaki, H
    Satoh, K
    Matsushita, S
    Kusakabe, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1348 - 1356
  • [4] Improved virtual bronchoscopy using a multi-slice helical CT scanner
    Summers, RM
    Sneller, MC
    Langford, CA
    Shelhamer, JH
    Wood, BJ
    MEDICAL IMAGING 2000: PHYSIOLOGY AND FUNCTION FORM MULTIDIMENSIONAL IMAGES, 2000, 3978 : 117 - 121
  • [5] Four-dimensional computed tomography using a 16-slice scanner
    Low, D
    Wahab, S
    ElNaqa, I
    Parikh, P
    Nystrom, M
    Kalinin, E
    Bradley, J
    Singh, A
    Mutic, S
    Dempsey, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1506 - 1506
  • [6] 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
    Pan, T
    Lee, TY
    Rietzel, E
    Chen, GTY
    MEDICAL PHYSICS, 2004, 31 (02) : 333 - 340
  • [7] Intrafractional Respiratory Motion for Charged Particle Lung Therapy with Immobilization Assessed by Four-Dimensional Computed Tomography
    Dobashi, Suguru
    Sugane, Toshio
    Mori, Shinichiro
    Asakura, Hiroshi
    Yamamoto, Naoyoshi
    Kumagai, Motoki
    Kandatsu, Susumu
    Baba, Masayuki
    JOURNAL OF RADIATION RESEARCH, 2011, 52 (01) : 96 - 102
  • [8] Accelerated Partial Breast Irradiation: Use of Four-Dimensional CT for Target Localization and Assessment of Intrafractional Motion
    Liao, Zhi-Wei
    Guan, Xun-Xing
    Li, Feng-Yan
    He, Zhen-Yu
    Xue, Ming
    Huang, Xiao-Yan
    Chen, Li-xin
    ONCOLOGY RESEARCH, 2010, 18 (10) : 503 - 507
  • [9] Four-dimensional radiation therapy for lung cancer using the second model 256-cletector row CT-scanner
    Shinichiro, M.
    Endo, M.
    Sunaoka, M.
    Kandatsu, S.
    Baba, M.
    EJC SUPPLEMENTS, 2005, 3 (02): : 408 - 408
  • [10] Multi-Plane Three-Dimensional and Four-Dimensional Echocardiography Against Multi-Slice Computed Tomography and Magnetic Resonance Angiography
    Cay, Serkan
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (05): : 739 - 739