Quantitative subtraction with direct digital dental radiography

被引:9
|
作者
Yoshioka, T
Kobayashi, C
Suda, H
Sasaki, T
机构
[1] Department of Endodontics, Faculty of Dentistry, Tokyo Medical and Dental University, Tokyo
[2] Department of Dental Radiology, Faculty of Dentistry, Tokyo Medical and Dental University, Tokyo
[3] Department of Endodontics, Faculty of Dentistry, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo 113
关键词
radiography; dental; subtraction technique; image processing; computer-assisted;
D O I
10.1038/sj.dmfr.4600259
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To elucidate the accuracy in vitro of quantitative digital subtraction for direct digital dental radiography using a commercially available image analysis system. Methods: Images were corrected first for dark current and sensitivity variation among pixels of the CCD sensor (first correction), and corrected further for interimage variations due to the variations in exposure conditions (second correction), A copper stepwedge with six steps was used in the second correction. Three corrected images derived from three original images at each different exposure time were examined to confirm the reliability of the second correction. Correlation between bone mineral content and pixel value was assessed in subtracted images of an artificial bone phantom. Results: The first and second corrections significantly improved the intra-and inter-image variation respectively, The second corrected images obtained at three different exposure times showed almost the identical grey levels, An original image was transformed to a copper equivalent image with a high reliability by our original method. The pixel value in the subtracted image between two copper equivalent images of a bone phantom was linearly related to the bone mineral content, There was a slight overestimate at lower pixel values but it was accurate at higher pixel values. Conclusions: Quantification of digital subtraction using this method is sufficeintly reliable for its application to clinical practice to be evaluated.
引用
收藏
页码:286 / 294
页数:9
相关论文
共 50 条
  • [31] REGISTRATION TECHNIQUES FOR DIGITAL SUBTRACTION RADIOGRAPHY
    SAMARABANDU, J
    ALLEN, K
    HAUSMANN, E
    ACHARYA, R
    DENTOMAXILLOFACIAL RADIOLOGY, 1994, 23 (02) : 117 - 117
  • [32] Novel Detection Method for Monitoring of Dental Caries Using Single Digital Subtraction Radiography
    Park, J. H.
    Choi, Y. S.
    Lee, G. J.
    Choi, S.
    Kim, K. S.
    Park, D. H.
    Cho, I.
    Park, H. K.
    26TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE: SBEC 2010, 2010, 32 : 463 - +
  • [33] Evaluation of three contrast correction methods for digital subtraction in dental radiography: An in vitro study
    Likar, B
    Pernus, F
    MEDICAL PHYSICS, 1997, 24 (02) : 299 - 307
  • [34] DIGITAL SUBTRACTION RADIOGRAPHY IN VOIDING CYSTOURETHROGRAPHY
    PERRI, G
    NAPOLI, V
    FALASCHI, F
    TRIPPI, D
    BAGNOLESI, P
    EUROPEAN JOURNAL OF RADIOLOGY, 1988, 8 (03) : 175 - 178
  • [35] CALIBRATION ERRORS IN DIGITAL SUBTRACTION RADIOGRAPHY
    WEBBER, RL
    RUTTIMANN, UE
    HEAVEN, TJ
    JOURNAL OF PERIODONTAL RESEARCH, 1990, 25 (05) : 268 - 275
  • [36] A New Subtraction Radiography Approach for Dental Applications
    Ozturk, Aydin
    Gungor, Cengiz
    Ergun, Selin
    Guneri, Pelin
    2009 IEEE 17TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, VOLS 1 AND 2, 2009, : 186 - +
  • [37] Evaluation of simulated external root resorptions with digital radiography and digital subtraction radiography
    Ono, Evelise
    Medici Filho, Edmundo
    Leite, Horacio Faig
    Oshiro Tanaka, Jefferson Luis
    Leonelli De Moraes, Mari Eli
    De Melo Castilho, Julio Cezar
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 139 (03) : 324 - 333
  • [38] Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions - Overall comparison between conventional and direct digital radiography
    Kullendorff, B
    Nilsson, M
    Rohlin, M
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 82 (03): : 344 - 350
  • [39] PERSONAL-COMPUTER EQUIPMENT FOR DENTAL DIGITAL SUBTRACTION RADIOGRAPHY VS INDUSTRIAL COMPUTER-EQUIPMENT AND CONVENTIONAL RADIOGRAPHY
    MOYSTAD, A
    SVANAES, DB
    LARHEIM, TA
    SCANDINAVIAN JOURNAL OF DENTAL RESEARCH, 1992, 100 (02): : 117 - 122
  • [40] Quantitative digital subtraction radiography for the determination of small changes in bone thickness - An in vitro study
    Christgau, M
    Hiller, KA
    Schmalz, G
    Kolbeck, C
    Wenzel, A
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1998, 85 (04): : 462 - 472