Quantitative subtraction with direct digital dental radiography

被引:9
|
作者
Yoshioka, T
Kobayashi, C
Suda, H
Sasaki, T
机构
[1] Department of Endodontics, Faculty of Dentistry, Tokyo Medical and Dental University, Tokyo
[2] Department of Dental Radiology, Faculty of Dentistry, Tokyo Medical and Dental University, Tokyo
[3] Department of Endodontics, Faculty of Dentistry, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo 113
关键词
radiography; dental; subtraction technique; image processing; computer-assisted;
D O I
10.1038/sj.dmfr.4600259
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To elucidate the accuracy in vitro of quantitative digital subtraction for direct digital dental radiography using a commercially available image analysis system. Methods: Images were corrected first for dark current and sensitivity variation among pixels of the CCD sensor (first correction), and corrected further for interimage variations due to the variations in exposure conditions (second correction), A copper stepwedge with six steps was used in the second correction. Three corrected images derived from three original images at each different exposure time were examined to confirm the reliability of the second correction. Correlation between bone mineral content and pixel value was assessed in subtracted images of an artificial bone phantom. Results: The first and second corrections significantly improved the intra-and inter-image variation respectively, The second corrected images obtained at three different exposure times showed almost the identical grey levels, An original image was transformed to a copper equivalent image with a high reliability by our original method. The pixel value in the subtracted image between two copper equivalent images of a bone phantom was linearly related to the bone mineral content, There was a slight overestimate at lower pixel values but it was accurate at higher pixel values. Conclusions: Quantification of digital subtraction using this method is sufficeintly reliable for its application to clinical practice to be evaluated.
引用
收藏
页码:286 / 294
页数:9
相关论文
共 50 条
  • [21] Evaluation of a dental subtraction radiography system
    Ellwood, RP
    Davies, RM
    Worthington, HV
    JOURNAL OF PERIODONTAL RESEARCH, 1997, 32 (02) : 241 - 248
  • [22] REAL-TIME SENSING OF TOOTH POSITION FOR DENTAL DIGITAL SUBTRACTION RADIOGRAPHY
    BURDEA, GC
    DUNN, SM
    IMMENDORF, CH
    MALLIK, M
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (04) : 366 - 378
  • [23] Efficacy of quantitative digital subtraction radiography using radiographs exposed in a multicenter trial
    Jeffcoat, MK
    Reddy, MS
    Magnusson, I
    Johnson, B
    Meredith, MP
    Cavanaugh, PF
    Gerlach, RW
    JOURNAL OF PERIODONTAL RESEARCH, 1996, 31 (03) : 157 - 160
  • [24] Intra-analyst variability using Quantitative Digital Subtraction Radiography.
    Winston, JL
    Pratt, JL
    Gerlach, RW
    Jeffcoat, MK
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 580 - 580
  • [25] Influence of developer exhaustion on accuracy of quantitative digital subtraction radiography - An in vitro study
    Fidler, A
    Likar, B
    Pernus, F
    Skaleric, U
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2000, 90 (02): : 233 - 239
  • [26] Analytical methodology in quantitative digital subtraction radiography: Analyses of the aluminum reference wedge
    Allen, KM
    Hausmann, E
    JOURNAL OF PERIODONTOLOGY, 1996, 67 (12) : 1317 - 1321
  • [27] The perceptibility curve test applied to direct digital dental radiography
    Yoshiura, K
    Stamatakis, H
    Shi, XQ
    Welander, U
    McDavid, WD
    Kristoffersen, J
    Tronje, G
    DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (03) : 131 - 135
  • [28] DIGITAL SUBTRACTION RADIOGRAPHY IN PEDIATRIC CYSTOURETHROGRAPHY
    PERRI, G
    FALASCHI, F
    NAPOLI, V
    BATTOLLA, L
    FEDERIGHI, F
    BANI, E
    CHILD NEPHROLOGY AND UROLOGY, 1992, 12 (01) : 40 - 42
  • [29] Digital dental radiography
    Niemiec, Brook A.
    JOURNAL OF VETERINARY DENTISTRY, 2007, 24 (03) : 192 - 197
  • [30] SOURCES OF NOISE IN DIGITAL SUBTRACTION RADIOGRAPHY
    WENZEL, A
    SEWERIN, I
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1991, 71 (04): : 503 - 508