Detection of acute myocardial ischemia during percutaneous transluminal coronary angioplasty by endocardial acceleration

被引:12
|
作者
Theres, HP
Kaiser, DR
Nelson, SD
Glos, M
Leuthold, T
Baumann, G
Sowelam, S
Sheldon, TJ
Stylos, L
机构
[1] Humboldt Univ, Charite, D-1086 Berlin, Germany
[2] Medtronic Inc, CRM Pacing & Monitoring Res, Minneapolis, MN USA
来源
关键词
first heart sound; endocardial acceleration; contractility; myocardial ischemia;
D O I
10.1111/j.1540-8159.2004.00496.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The first heart sound is generated by vibrations from the myocardium during isovolumic contraction. Peak endocardiol acceleration (PEA) has been used previously to measure these vibrations in humans and correlates with myocardial contractility during inotropic interventions. It is unknown if changes in PEA can be used to characterize a reduction in contractility during ischemic episodes. This study was designed to evaluate the use of an endocardial accelerometer for the detection of acute myocardial ischemia. Thirteen patients undergoing routine percutaneous transluminal coronary angioplasty (PTCA) consented to having a single-axis, lead-based accelerometer positioned in the right ventricular apex. PEA was defined as the maximum peak-to-peuk amplitude during a window 50 ms before to 200 ms following the peak R wave. Time of endocardial acceleration (TEA) was defined as the time from the peak R wave to the maximum accelerometer signal within this window To obtain a more robust estimate of the strength of vibrations, a 100-beat template of the accelerometer signal was constructed at baseline and applied as a matched filter during ischemia. The peak magnitude of the filtered endocardial accelerometer signal (Max Filtered EA) was used as an index of signal intensity Median baseline PEA, TEA, and Max Filtered EA were 0.91 +/- 0.35 g, 75.2 +/- 16.2 ms, and 0.40 +/- 0.20 g, respectively. PEA and Max Filtered EA significantly decreased by 7% during ischemia (0,91 to 0.85 g and 0.40 to 0.37 g both P < 0.05, respectively). TEA did not significantly change from baseline (77.0 ms, P = ns). The results of this study suggest that acute ischemia can be detected with on endocardial accelerometer in humans.
引用
收藏
页码:621 / 625
页数:5
相关论文
共 50 条
  • [31] Primary percutaneous transluminal coronary angioplasty in diabetic pacients with acute myocardial infarction
    Borges, I. P.
    Peixoto, R. T. S.
    Peixoto, E. C. S.
    Peixoto, R. T. S.
    Aragao, A. A. B.
    Marcolla, V. F.
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2016, 15 : S92 - S93
  • [32] Emergency percutaneous transluminal coronary angioplasty in 52 patients with acute myocardial infarction
    刘映峰
    钱学贤
    傅向阳
    叶文胜
    刘磊
    吴志坚
    李公信
    李志梁
    卢东风
    赵夏
    ChineseMedicalJournal, 1998, (03)
  • [33] Emergency percutaneous transluminal coronary angioplasty in 52 patients with acute myocardial infarction
    Liu, YF
    Qian, XX
    Fu, XY
    Ye, WS
    Liu, L
    Wu, ZJ
    Li, GX
    Li, ZL
    Lu, DF
    Zhao, X
    CHINESE MEDICAL JOURNAL, 1998, 111 (03) : 213 - 213
  • [34] Emergency percutaneous transluminal coronary angioplasty in 52 patients with acute myocardial infarction
    刘映峰
    钱学贤
    傅向阳
    叶文胜
    刘磊
    吴志坚
    李公信
    李志梁
    卢东风
    赵夏
    中华医学杂志(英文版), 1998, (03) : 21 - 21
  • [35] A comparison of systematic stenting and conventional balloon angioplasty during primary percutaneous transluminal coronary angioplasty for acute myocardial infarction
    Maillard, L
    Hamon, M
    Khalife, K
    Steg, PG
    Beygui, F
    Guermonprez, JL
    Spaulding, CM
    Boulenc, JM
    Lipiecki, J
    Lafont, A
    Brunel, P
    Grollier, G
    Koning, R
    Coste, P
    Favereau, X
    Lancelin, B
    Van Belle, E
    Serruys, P
    Monassier, JP
    Raynaud, P
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (07) : 1729 - 1736
  • [36] Transcranial Doppler detection of microemboli during percutaneous transluminal coronary angioplasty
    Bladin, CF
    Bingham, L
    Grigg, L
    Yapanis, AG
    Gerraty, R
    Davis, SM
    STROKE, 1998, 29 (11) : 2367 - 2370
  • [37] Are the results of primary percutaneous transluminal coronary angioplasty for acute myocardial infarction different during the ''off'' hours?
    Garot, P
    Juliard, JM
    Benamer, H
    Steg, PG
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (11): : 1527 - &
  • [38] EFFECTIVENESS OF PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY IN CARDIOGENIC-SHOCK DURING ACUTE MYOCARDIAL-INFARCTION
    SEYDOUX, C
    GOY, JJ
    BEURET, P
    STAUFFER, JC
    VOGT, P
    SCHALLER, MD
    KAPPENBERGER, L
    PERRET, C
    AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (09): : 968 - 969
  • [39] A comparison of electrocardiographic changes during reperfusion of acute myocardial infarction by thrombolysis or percutaneous transluminal coronary angioplasty
    Wehrens, XHT
    Doevendans, PA
    Ophuis, TJO
    Wellens, HJJ
    AMERICAN HEART JOURNAL, 2000, 139 (03) : 430 - 436
  • [40] The calcium sensitizer levosimendan improves the function of stunned myocardium after percutaneous transluminal coronary angioplasty in acute myocardial ischemia
    Sonntag, S
    Sundberg, S
    Lehtonen, LA
    Kleber, FX
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (12) : 2177 - 2182